Plan Review Details - Permit 06021187
Plan Review Stops For Permit 06021187
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-10-17 Cont ID  
Sent By alange Date 2006-10-17 Time 14:30 Rev Time 0.00
Received By alange Date 2006-10-17 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-31 Cont ID  
Sent By alange Date 2006-03-31 Time 09:42 Rev Time 0.00
Received By alange Date 2006-03-31 Time 09:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-10-12 Cont ID  
Sent By btrobaug Date 2006-10-12 Time 06:59 Rev Time 0.33
Received By btrobaug Date 2006-10-12 Time 06:59 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-23 Cont ID  
Sent By btrobaug Date 2006-03-23 Time 12:47 Rev Time 0.50
Received By btrobaug Date 2006-03-23 Time 12:41 Sent To M
Notes
2006-03-23 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE A SITE PLAN INDICATING
 THE LOCATION OF ALL EQUIPMENT INVOLVED,
 SERVICE AND OPTIONAL, SO THAT COMPLIANCE
 WITH ARTICLES 225.31 THROUGH 225.39
 INCLUSIVE CAN BE REVIEWED.
  
 2} PROVIDE A CALCULATION OF THE LOAD TO
 BE SUPPLIED BY THE GENERATOR IN
 COMPLIANCE WITH 702.5.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-03-28 Cont ID  
Sent By mperson Date 2006-03-28 Time 09:57 Rev Time 0.15
Received By mperson Date 2006-03-28 Time 09:57 Sent To B
Notes
2006-03-28 00:00:00NOTE: GAS PERMIT REQUIRED. GAS
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT
 APPLICATION. ALL GAS INSPECTIONS TO BE
 COMPLETE BEFORE FINAL RES-GEN
 INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 09:27 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 09:27 Sent To E
Notes
2006-10-10 09:28:01TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-03 Cont ID  
Sent By adarroug Date 2006-10-03 Time 14:00 Rev Time 0.00
Received By adarroug Date 2006-10-03 Time 14:00 Sent To Z
Notes
2006-10-03 00:00:00TO "Z" BOX/RESUB--SUBMITTED SHEETS
 W/COPY OF ZONING STAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 10:59 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 10:59 Sent To E
Notes
2006-03-09 00:00:00TO "GEN-RES" BOX "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-31 Cont ID  
Sent By alange Date 2006-03-31 Time 09:43 Rev Time 0.00
Received By alange Date 2006-03-02 Time 12:13 Sent To  
Notes
2006-03-02 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-10-12 Cont ID  
Sent By tgordon Date 2006-10-12 Time 09:54 Rev Time 0.15
Received By tgordon Date 2006-10-12 Time 09:54 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-03-27 Cont ID  
Sent By tgordon Date 2006-03-27 Time 16:31 Rev Time 0.15
Received By tgordon Date 2006-03-27 Time 16:31 Sent To P
Notes
2006-03-27 00:00:00*** PROVISO ***
 1) GENERATOR EXHUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJECENT BUILDING
 OPENS. PER 2004 FBC/M 401.5.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-03-28 Cont ID  
Sent By mperson Date 2006-03-28 Time 09:56 Rev Time 0.00
Received By mperson Date 2006-03-28 Time 09:56 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-10-05 Cont ID  
Sent By kdfreema Date 2006-10-05 Time 12:39 Rev Time 0.00
Received By kdfreema Date 2006-10-05 Time 12:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-03-08 Cont ID  
Sent By mmclean Date 2006-03-08 Time 15:43 Rev Time 0.00
Received By mmclean Date 2006-03-08 Time 15:43 Sent To I
Notes
2006-03-08 00:00:00NOTE: GENERATOR CAN ONLY BE 4FT INTO
 SETBACK.


Account Summary | Usage Policy | Privacy Policy