Plan Review Details - Permit 06021123
Plan Review Stops For Permit 06021123
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-05-02 Cont ID  
Sent By lursu Date 2006-05-02 Time 11:43 Rev Time 0.00
Received By lursu Date 2006-05-01 Time 14:01 Sent To  
Notes
2006-05-02 00:00:00ADDED EXT #0001 : 537 CLEMATIS ST FOR
 THE TENANT (RESTAURANT) CORINA'S IN THE
 CITY;UNDER THE MAIN ADDRESS:533 CLEMATIS
 ST,PCN= 74434321010250063
2006-05-01 00:00:00VERIFICATION IN PROCESS .

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-18 Cont ID  
Sent By rmcdouga Date 2006-05-18 Time 07:45 Rev Time 0.00
Received By rmcdouga Date 2006-05-18 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-04-27 Cont ID  
Sent By rmcdouga Date 2006-04-27 Time 08:33 Rev Time 0.00
Received By rmcdouga Date 2006-04-27 Time 07:29 Sent To  
Notes
2006-04-27 00:00:00DENIED
  
 ADDRESS ON THE PLANS OF 560 CLEMATIS
 DOES NOT MATCH THE ADDRESS OF 533
 CLEMATIS THAT IS ON THE PERMIT
 APPLICATION. ADDRESS MUST BE CORRECTED
 BEFORE PERMIT CAN BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-30 Cont ID  
Sent By rmcdouga Date 2006-03-30 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2006-03-30 Time 13:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-08-15 Cont ID  
Sent By btrobaug Date 2006-08-14 Time 18:26 Rev Time 0.75
Received By btrobaug Date 2006-08-14 Time 18:10 Sent To PC
Notes
2006-08-15 00:00:00THE ARCHITECT (DESIGNER OF RECORD) CAME
 TO CITY HALL AND STAMPED PLANS./WRT.
2006-08-14 00:00:00 
  
  
 NONCOMPLIANT
  
 THE ARCHITECT OF RECORD MUST SEAL THE
 PLAN HE DESIGNED. THE ENGINEER WAS NOT
 THE DESIGNER OF RECORD.FS 481 AND
 471.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-05-16 Cont ID  
Sent By btrobaug Date 2006-05-16 Time 18:16 Rev Time 0.50
Received By btrobaug Date 2006-05-16 Time 17:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-27 Cont ID  
Sent By btrobaug Date 2006-04-27 Time 17:34 Rev Time 0.50
Received By btrobaug Date 2006-04-27 Time 17:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-03-28 Cont ID  
Sent By btrobaug Date 2006-03-28 Time 16:15 Rev Time 0.50
Received By btrobaug Date 2006-03-28 Time 15:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-05-23 Cont ID  
Sent By mwennerg Date 2006-05-23 Time 11:26 Rev Time 0.00
Received By mwennerg Date 2006-05-23 Time 11:25 Sent To P
Notes
2006-05-23 00:00:00NEW SHEETS RESUBMITTED

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-03-30 Cont ID  
Sent By mwennerg Date 2006-03-30 Time 10:48 Rev Time 0.00
Received By mwennerg Date 2006-03-30 Time 10:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-08-14 Cont ID  
Sent By adarroug Date 2006-08-14 Time 15:56 Rev Time 0.00
Received By adarroug Date 2006-08-14 Time 15:56 Sent To E
Notes
2006-08-14 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-06-15 Cont ID  
Sent By adarroug Date 2006-06-15 Time 11:13 Rev Time 0.00
Received By adarroug Date 2006-06-15 Time 11:13 Sent To P
Notes
2006-06-15 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-16 Cont ID  
Sent By adarroug Date 2006-05-16 Time 11:31 Rev Time 0.00
Received By adarroug Date 2006-05-16 Time 11:31 Sent To  
Notes
2006-05-16 00:00:00WAITING FOR "BOB"
 TO "BOB"#10

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 16:51 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 16:51 Sent To AD
Notes
2006-04-27 00:00:00TO "ADD" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-19 Cont ID  
Sent By adarroug Date 2006-04-19 Time 14:56 Rev Time 0.00
Received By adarroug Date 2006-04-19 Time 14:56 Sent To  
Notes
2006-04-26 00:00:00TO "BOB"#2
2006-04-19 00:00:00WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-06 Cont ID  
Sent By adarroug Date 2006-03-06 Time 15:01 Rev Time 0.00
Received By adarroug Date 2006-03-06 Time 15:01 Sent To B
Notes
2006-03-28 00:00:00TO "BOB"#6-PER "RBROWN"
2006-03-06 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-30 Cont ID  
Sent By rmcdouga Date 2006-03-30 Time 13:21 Rev Time 0.00
Received By rmcdouga Date 2006-02-28 Time 18:42 Sent To  
Notes
2006-02-28 00:00:00TO "Z" BOX FOR (DMP)

Review Stop P PLUMBING
Rev No 5 Status P Date 2006-07-05 Cont ID  
Sent By jleech Date 2006-07-05 Time 07:31 Rev Time 0.00
Received By jleech Date 2006-07-05 Time 07:31 Sent To  
Notes
2006-07-05 00:00:00REVISION; DELETED GREASE TRAP. WAVER
 FROM UTILITIES.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-06-06 Cont ID  
Sent By jleech Date 2006-06-06 Time 13:34 Rev Time 0.00
Received By jleech Date 2006-06-06 Time 13:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-05-25 Cont ID  
Sent By pschmitz Date 2006-05-25 Time 08:44 Rev Time 0.00
Received By pschmitz Date 2006-05-25 Time 08:44 Sent To  
Notes
2006-05-25 00:00:00PAUL SCHMITZ
 [email protected]
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 PLUMBING CODEPLAN REVIEW
 FBC 2004 FL ACESSIBILITY CODE PLAN
 REVIEW
 UNSAT
  
 PREVIOUS NOTE FROM PLAN REVIEW DATED
 4-29-06 BY JHL
 C)INFORNATION ON GREASE TRAP AND GREASE
 WASTE PIPING NOT COMPLETED.
  
 END OF COMMENTS QUESTIONS 561-808-6692
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-04-29 Cont ID  
Sent By jleech Date 2006-04-29 Time 13:52 Rev Time 0.00
Received By jleech Date 2006-04-29 Time 13:52 Sent To  
Notes
2006-04-29 00:00:00DENIED;
 COMMENTS NOT ADDRESSED;
 A. NOTE 3 INDIRECT WASTE RECEPTORS FOR,
 SODA DISPENSOR, ICE MACHINE, AND STEAM
 TABLES. SHOW HOW THIS EQUIPMENT DRAINS.
 B. NOTE 4 3 COMPARTMENT SINK SHALL DRAIN
 INDIRECTLY, SO SINK CAN BE USED FOR FOOD
 PREP.
 C.NOTE 6 PLEASE CONTACT UTILITY
 DEPARTMENT FOR GREASE TRAP REQUIREMENTS.
 WASTE ORD.#3434 CONTACT;
 LYNN MASSON
 822-2279
 822-2279 FAX
 E-MAIL [email protected]
  
 WATER HEATER DIAGRAM; HEATER PAN
 REQUIRED WITH 3/4" DRAIN TO THE OUTSIDE.
 PLEASE SHOW ON DETAIL
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-29 Cont ID  
Sent By jleech Date 2006-03-29 Time 12:56 Rev Time 3.00
Received By jleech Date 2006-03-29 Time 12:56 Sent To  
Notes
2006-03-29 00:00:00DENIED;
 1.PLANS ARE TO BE REVIEWED AND APPROVED
 BY THE DIVISION OF HOTEL AND RESTAURANTS
 BEFORE RESUB TO THE CITY.
 2.A SERVICE SINK IS REQUIRED PER
 FBC-2004 PLUMBING TABLE 403.1.
 3.FLOOR SINKS ARE REQUIRED FOR INDIRECT
 WASTES. (SODA DISPENSOR, ICE MACHINE,
 AND STEAM TABLE).
 4.FOOD PREP AREA DOES NOT HAVE A SINK
 FOR STORING OR PREPARATION OF FOOD. SO
 THE 3 COMPARTMENT SINK SHOULD DRAIN
 INDIRECTLY SEC. 802.1.1.
 5.WATER HEATER. SHOW DETAIL OF PLATFORM,
 AND LIST MATERIAL TO BE USED. SHOW PAN
 DRAIN AND LOCATION OF DISPOSAL AREA FOR
 PAN DRAIN. COMPLY WITH SEC.504.7.2.
 THERMAL EXPANSION CONTROL IS ALSO
 REQUIRED PER. SEC. 607.3
 6.PLEASE CHECK WITH RODMEY COMPO
 (ENVIRONMENT COMPLIANCE TECHNICIAN) WITH
 THE UTILITY DEPARTMENT FOR A GREASE TRAP
 WAVER. 822-2200 EXT 2272
 E-MAIL, [email protected].
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2006-03-06 Cont ID  
Sent By mmclean Date 2006-03-06 Time 11:24 Rev Time 0.00
Received By mmclean Date 2006-03-06 Time 11:24 Sent To I
Notes
2006-03-06 00:00:00NOTE: NO ZONING REQUIRED.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved