| Plan Review Stops For Permit 06021123 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-05-02 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-05-01 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2006-05-02 00:00:00 | ADDED EXT #0001 : 537 CLEMATIS ST FOR | | | THE TENANT (RESTAURANT) CORINA'S IN THE | | | CITY;UNDER THE MAIN ADDRESS:533 CLEMATIS | | | ST,PCN= 74434321010250063 | | 2006-05-01 00:00:00 | VERIFICATION IN PROCESS . |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-05-18 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-05-18 |
Time |
07:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-04-27 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-27 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2006-04-27 00:00:00 | DENIED | | | | | | ADDRESS ON THE PLANS OF 560 CLEMATIS | | | DOES NOT MATCH THE ADDRESS OF 533 | | | CLEMATIS THAT IS ON THE PERMIT | | | APPLICATION. ADDRESS MUST BE CORRECTED | | | BEFORE PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-30 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-30 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-14 |
Time |
18:26 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-14 |
Time |
18:10 |
Sent To |
PC |
|
| Notes |
| 2006-08-15 00:00:00 | THE ARCHITECT (DESIGNER OF RECORD) CAME | | | TO CITY HALL AND STAMPED PLANS./WRT. | | 2006-08-14 00:00:00 | | | | | | | | | | NONCOMPLIANT | | | | | | THE ARCHITECT OF RECORD MUST SEAL THE | | | PLAN HE DESIGNED. THE ENGINEER WAS NOT | | | THE DESIGNER OF RECORD.FS 481 AND | | | 471. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-16 |
Time |
18:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-16 |
Time |
17:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-27 |
Time |
17:34 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-27 |
Time |
17:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-28 |
Time |
16:15 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-28 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-23 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-23 |
Time |
11:25 |
Sent To |
P |
|
| Notes |
| 2006-05-23 00:00:00 | NEW SHEETS RESUBMITTED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-30 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-30 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
15:56 |
Sent To |
E |
|
| Notes |
| 2006-08-14 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
11:13 |
Sent To |
P |
|
| Notes |
| 2006-06-15 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-16 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-16 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | WAITING FOR "BOB" | | | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
16:51 |
Sent To |
AD |
|
| Notes |
| 2006-04-27 00:00:00 | TO "ADD" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-19 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-19 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2006-04-26 00:00:00 | TO "BOB"#2 | | 2006-04-19 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-06 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-06 |
Time |
15:01 |
Sent To |
B |
|
| Notes |
| 2006-03-28 00:00:00 | TO "BOB"#6-PER "RBROWN" | | 2006-03-06 00:00:00 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-30 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-28 |
Time |
18:42 |
Sent To |
|
|
| Notes |
| 2006-02-28 00:00:00 | TO "Z" BOX FOR (DMP) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-05 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-05 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | REVISION; DELETED GREASE TRAP. WAVER | | | FROM UTILITIES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-06 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-06 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-25 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-25 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2006-05-25 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 PLUMBING CODEPLAN REVIEW | | | FBC 2004 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | UNSAT | | | | | | PREVIOUS NOTE FROM PLAN REVIEW DATED | | | 4-29-06 BY JHL | | | C)INFORNATION ON GREASE TRAP AND GREASE | | | WASTE PIPING NOT COMPLETED. | | | | | | END OF COMMENTS QUESTIONS 561-808-6692 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-04-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-29 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-29 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-04-29 00:00:00 | DENIED; | | | COMMENTS NOT ADDRESSED; | | | A. NOTE 3 INDIRECT WASTE RECEPTORS FOR, | | | SODA DISPENSOR, ICE MACHINE, AND STEAM | | | TABLES. SHOW HOW THIS EQUIPMENT DRAINS. | | | B. NOTE 4 3 COMPARTMENT SINK SHALL DRAIN | | | INDIRECTLY, SO SINK CAN BE USED FOR FOOD | | | PREP. | | | C.NOTE 6 PLEASE CONTACT UTILITY | | | DEPARTMENT FOR GREASE TRAP REQUIREMENTS. | | | WASTE ORD.#3434 CONTACT; | | | LYNN MASSON | | | 822-2279 | | | 822-2279 FAX | | | E-MAIL [email protected] | | | | | | WATER HEATER DIAGRAM; HEATER PAN | | | REQUIRED WITH 3/4" DRAIN TO THE OUTSIDE. | | | PLEASE SHOW ON DETAIL | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-29 |
Time |
12:56 |
Rev Time |
3.00 |
| Received By |
jleech |
Date |
2006-03-29 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2006-03-29 00:00:00 | DENIED; | | | 1.PLANS ARE TO BE REVIEWED AND APPROVED | | | BY THE DIVISION OF HOTEL AND RESTAURANTS | | | BEFORE RESUB TO THE CITY. | | | 2.A SERVICE SINK IS REQUIRED PER | | | FBC-2004 PLUMBING TABLE 403.1. | | | 3.FLOOR SINKS ARE REQUIRED FOR INDIRECT | | | WASTES. (SODA DISPENSOR, ICE MACHINE, | | | AND STEAM TABLE). | | | 4.FOOD PREP AREA DOES NOT HAVE A SINK | | | FOR STORING OR PREPARATION OF FOOD. SO | | | THE 3 COMPARTMENT SINK SHOULD DRAIN | | | INDIRECTLY SEC. 802.1.1. | | | 5.WATER HEATER. SHOW DETAIL OF PLATFORM, | | | AND LIST MATERIAL TO BE USED. SHOW PAN | | | DRAIN AND LOCATION OF DISPOSAL AREA FOR | | | PAN DRAIN. COMPLY WITH SEC.504.7.2. | | | THERMAL EXPANSION CONTROL IS ALSO | | | REQUIRED PER. SEC. 607.3 | | | 6.PLEASE CHECK WITH RODMEY COMPO | | | (ENVIRONMENT COMPLIANCE TECHNICIAN) WITH | | | THE UTILITY DEPARTMENT FOR A GREASE TRAP | | | WAVER. 822-2200 EXT 2272 | | | E-MAIL, [email protected]. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-06 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-06 |
Time |
11:24 |
Sent To |
I |
|
| Notes |
| 2006-03-06 00:00:00 | NOTE: NO ZONING REQUIRED. |
|
|