| 2006-12-27 09:32:49 | BASED ON THE E-MAIL SENT BY THE CONTRACTOR | | | [email protected], THE PROPERTY OWNER IS | | | WEST PALM BEACH CONCOURSE PLAZA AND THE TENANT IS | | | DYNAMIC GROWTH PARTNERS,INC.THE PROOF OF OWNERSHIP IS | | | NOT REQUIRED ANYMORE SINCE IS THE PERMIT APPLICATION | | | AND PROPERTY APPRAISER HAVE THE SAME OWNERSHIP | | | INFORMATION .PERMIT WAS ATTACHED TO THE CORRECT | | | RECORD. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | OFFICE:822-1239 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-20 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-20 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2006-12-20 11:44:08 | ON THE ORIGINAL PERMIT APPLICATION THE OWNER OF RECORD | | | IS LISTED AS DYNAMIC GROWTH PARTNERS INC. | | | HOWEVER IN THE PROPERTY APPRASIER'S DATA UNDER THE | | | ABOVE PARCEL CONTROL NUMBER THE OWNER OF RECORD IS | | | LISTED AS WEST PALM BCH CONCOURSE PLAZA. | | | IF THE OWNER ON THE APPLICATION IS CORRECT THEN THE | | | PROOF OF OWNERSHIP IS NEEDED BEFORE ISSUING THE | | | PERMIT. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-12-15 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-12-15 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2006-12-15 08:44:07 | PERMIT ATTACHED TO THE CORRECT ADDRESS. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | E-MAIL:[email protected] | | 2006-02-23 00:00:00 | TOLD MARC GEFTMAN WE WILL NEED LEGAL | | | DOCUMENT TO CHANGE OWNER INFO BEFORE WE | | | CAN ISSUE PERMIT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-11 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-11 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2007-01-11 16:17:15 | CONTRACTOR APPLIED FOR PERMIT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-01-02 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-01-02 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2007-01-02 11:21:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)THIS HAS BEEN SUBMITTED FOR PLAN CHECK ONLY. | | | PLEASE APPLY FOR PERMIT. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-05 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-05 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC RFLORIDA BUILDING CODE 2004 | | | RESIDENTIAL | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LISTS: | | | | | | 1.)A NOTICE OF COMMENCEMENT REQUIRED, | | | FS713.13. | | | | | | 2.)DECLARE OCCUPANCY, FBC 3. | | | | | | 6.)THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR THE ARCHITECT FIRM IS TO BE | | | ON EACH SHEET, FAC61G1-16.003, 004.SEE | | | ALSO ELECTRIC REVIEWER?S COMMENTS | | | REGARDING TURNKEY CONCEPTS, INC. | | | | | | 11.)PLANS STATE THAT THIS IS TYPE IV | | | UPROTECTED.THIS IS HEAVY TIMBER.TO | | | MY KNOWLEDGE, THERE IS ONLY ONE HEAVY | | | TIMBER BUILDING IN THE CITY OF WEST PALM | | | BEACH AND IT IS NOT THIS BUILDING. | | | PLEASE CONFIRM THAT THIS IS A HEAVY | | | TIMBER BUILDING. | | | | | | PLANS STATE THAT THIS BUILDING IS NOT | | | REQUIRED TO BE SPRINKLED.YOU HAVE ALSO | | | STATED THAT THE BUILDING IS 21450 SF. | | | IT APPEARS THAT DUE TO THE SIZE OF THE | | | BUILDING, IT IS LIKELY THAT IT IS | | | REQUIRED BY CODE TO BE FULLY SPRINKLED. | | | OUR RECORDS SHOW A FIRE ALARM/FIRE | | | SPRINKLER PERMIT ISSUED IN THE PAST. | | | ADDRESS. | | | | | | IF THE BUILDING IS REQUIRED TO BE | | | SPRINKLED, FIRE SPRINKLER PLANS | | | REQUIRED. | | | | | | 13.)SHOW ACCESS AISLES, FBC11-5.3. | | | | | | 15.)SHOW MANEUVERING CLEARANCE, DOOR | | | 5, FBC 11 FIGURE 25, FBC11-4.13.6.THE | | | DIMENSIONS SHOWN ARE FOR THE PUSH SIDE, | | | THIS IS THE PULL SIDE OF THE DOOR. | | | | | | 16.)DOORS 5 AND 6, SHOW COMPLIANCE | | | WITH FBC1008.1.8.8, LEAVE UNOBSTRUCTED | | | HALF THE REQUIRED WIDTH.ALSO DOOR 4. | | | THE RESPONSE LETTER STATES THAT THE REAR | | | DOOR IS NOT AN EXIT.SEE ITEM 19. | | | ALSO, EVEN IF ONE EXIT REQUIRED, SOMEONE | | | WHO IS IN THE RESTROOM WILL EXIT THROUGH | | | THE HALLWAY, WITH DOORS 4 AND 6 BLOCKING | | | THE REQUIRED WIDTH.SOMEONE IN THE | | | COOLER AREA ATTEMPTING TO EXIT THE | | | KITCHEN AREA THROUGH DOOR 6 WOULD PASS | | | DOOR 5, WHICH BLOCKS OVER HALF THE | | | REQUIRED WIDTH. | | | | | | 19.)PLANS STATE THAT ONE EXIT IS | | | REQUIRED.OCCUPANT LOAD DOES NOT MEET | | | THE EXCEPTION FOR ONE EXIT FBC TABLE | | | 1018.2.BASED ON INFORMATION PROVIDED, | | | TWO EXITS ARE REQUIRED. | | | | | | NEW COMMENT: | | | | | | 20.)ENERGY CALCS STATE 1800 SF, PLANS | | | STATE 1747.REVISE. | | | | | | 21.)WHAT IS THE CURRENT OCCUPANCY | | | CLASSIFICATION OF THIS SPACE?I WAS | | | UNABLE TO LOCATE AN OCCUPATIONAL LICENSE | | | FOR THIS ADDRESS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-18 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-18 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | ****CORRECTIONS**** | | | ****MAJOR WORKING DRAWING REVIEW**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)DECLARE OCCUPANCY, FBC CHAPTER 3. | | | | | | 3.)SIGN OWNER/AGENT LINE OF ENERGY | | | CALC, FBC13-103.1. | | | | | | 4.)THE SEAL FOR THE ARCHITECT IS TO BE | | | DATED, FAC61G1-16. | | | | | | 5.)THE SEAL FOR THE ENGINEER IS | | | EXPIRED, FAC61G15-23. (ENERGY CALCS) | | | | | | 6.)THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR THE ARCHITECT FIRM IS TO BE | | | ON EACH SHEET, FAC61G1-16.003, 004. | | | | | | 7.)THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT IS TO BE ON EACH | | | SHEET, FAC61G1-16.003, 004. | | | | | | 8.)GOVERNING CODES ARE FBC2004, | | | FBC2004 EXISTING BUILDING CODE. | | | | | | 9.)THE PLAN STATES THAT THE BUILDING | | | DEPARTMENT IS PALM BEACH COUNTY, SHOULD | | | STATE CITY OF WEST PALM BEACH. | | | | | | 10.)ADDRESSED. | | | | | | 11.)PROVIDE INFORMATION IN REGARDS TO | | | THE EXISTING BUILDING; HEIGHT, AREA, | | | MINIMUM BUILDING TYPE FBC6, SPRINKLED OR | | | UNSPRINKLED.IF THE BUILDING IS | | | REQUIRED TO BE SPRINKLED, FIRE SPRINKLER | | | PLANS REQUIRED. | | | | | | 12.)SHOW THE REQUIRED CLEAR FLOOR | | | SPACE AT THE SINKS, MEN?S TOILET AND | | | WOMEN?S TOILET, FBC11-4.24.5. | | | | | | 13.)SHOW ACCESS AISLES, FBC11-5.3. | | | | | | 14.)PROVIDE THE HEIGHT OF THE POS | | | AREA, A1.2, FBC11-7.2. | | | | | | 15.)SHOW MANEUVERING CLEARANCE, DOOR | | | 5, FBC11 FIGURE 25, FBC11-4.13.6. | | | | | | 16.)DOORS 5 AND 6, SHOW COMPLIANCE | | | WITH FBC1008.1.8.8, LEAVE UNOBSTRUCTED | | | HALF THE REQUIRED WIDTH. | | | | | | NEW COMMENTS: | | | | | | 17.)ENERGY CALCS ARE TO BE FBC2004. | | | | | | 18.)DECLARE OCCUPANT LOAD.COVER | | | SHEET SHOWS SEATING OF 44, WHAT ABOUT | | | EMPLOYEES? | | | | | | 19.)SHOW TRAVEL DISTANCE.PLANS STATE | | | THAT ONE EXIT IS REQUIRED.TWO ARE | | | SHOWN, BUT PLANS HAVE NOW BEEN REVISED | | | SO THAT DOORS 3 AND 4 DO NOT COMPLY WITH | | | FBC1008.1.1.8.ADDRESS. | | | | | | 20.)DECLARE LEVEL OF ALTERATION, FBC | | | EB CHAPTER 3. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-08 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-08 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | ****CORRECTIONS**** | | | ****MAJOR WORKING DRAWING REVIEW**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)DECLARE OCCUPANCY, FBC CHAPTER 3. | | | | | | 3.)SIGN OWNER/AGENT LINE OF ENERGY | | | CALC, FBC13-103.1 | | | | | | 4.)THE SEAL FOR THE ARCHITECT IS TO BE | | | DATED, FAC61G1-16. | | | | | | 5.)THE SEAL FOR THE ENGINEER IS | | | EXPIRED, FAC61G15-23. | | | | | | 6.)THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR THE ARCHITECT FIRM IS TO BE | | | ON EACH SHEET, FAC61G1-16.003, 004. | | | | | | 7.)THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT IS TO BE ON EACH | | | SHEET, FAC61G1-16.003, 004. | | | | | | 8.)GOVERNING CODES ARE FBC2004, | | | FBC2004 EXISTING BUILDING CODE. | | | | | | 9.)THE PLAN STATES THAT THE BUILDING | | | DEPARTMENT IS PALM BEACH COUNTY, SHOULD | | | STATE CITY OF WEST PALM BEACH. | | | | | | 10.)HANDICAP CODE REFERS TO DADE | | | COUNTY, GOVERNING ACCESSIBILITY CODE IS | | | FBC2004 CHAPTER 11. | | | | | | 11.)PROVIDE INFORMATION IN REGARDS TO | | | THE EXISTING BUILDING; HEIGHT, AREA, | | | MINIMUM BUILDING TYPE FBC6, SPRINKLED OR | | | UNSPRINKLED.IF THE BUILDING IS | | | REQUIRED TO BE SPRINKLED, FIRE SPRINKLER | | | PLANS REQUIRED. | | | | | | 12.)SHOW THE REQUIRED CLEAR FLOOR | | | SPACE AT THE SINKS, MEN?S TOILET AND | | | WOMEN?S TOILET, FBC11-4.24.5. | | | | | | 13.)SHOW ACCESS AISLES, FBC11-5.3. | | | | | | 14.)PROVIDE THE HEIGHT OF THE POS | | | AREA, A1.2, FBC11-7.2. | | | | | | 15.)SHOW MANEUVERING CLEARANCE, DOOR | | | 5, FBC11 FIGURE 25, FBC11-4.13.6. | | | | | | 16.)DOORS 5 AND 6, SHOW COMPLIANCE | | | WITH FBC1008.1.8.8, LEAVE UNOBSTRUCTED | | | HALF THE REQUIRED WIDTH. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-14 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-14 |
Time |
10:58 |
Sent To |
PC |
|
| Notes |
| 2007-01-14 11:37:46 | *** THIS IS UNDER THE 2006 REVSIONS TO THE 2004 FBC AND | | | THE 2005 NEC. | | | DID NOT APPLY FOR PERMIT UNTIL JAN 8TH, 2007 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-28 |
Time |
20:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-28 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2006-11-28 20:20:46 | **** UNSAT *** | | | | | | 1) NOTE: PLEASE KNOW AS THE PLANS HAVE STILL ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW", STAMPING AND PASSING OF | | | ELECTRICAL PLANS ARE NOT POSSIBLE AT THIS TIME. PLEASE | | | KNOW AS THIS PROJECT HAS NOT APPLIED FOR PERMIT, PLEASE | | | KNOW AS OF DEC 8TH, 2006 THE STATE OF FLORIDA WILL | | | ADOPT THE 2005 NEC (NATIONAL ELECTRICAL CODE) AND ANY | | | PERMIT APPLICATIONS MAY AFTER THAT DATE WILL HAVE TO | | | COMPLY WITH NEW CODE. AS THIS PROJECT HAS NOT BEEN | | | SUBMITTED FOR PERMIT, THIS WILL NOT FALL UNDER THE | | | PRESENT 2002 NEC. CHANGES IN DESIGN AND CODES WILL BE | | | REQUIRED. | | | PLANS CAN NOT BE STAMPED AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS, COMMENTS OR IF ANY PART OF | | | NOTES ABOVE ARE NOT UNDERSTOOD OR TYPED IN A MANNER | | | WHICH IS NOT CLEAR, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE OR REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-01 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-01 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2006-10-01 00:00:00 | *** UNSAT 3RD REVIEW *** | | | | | | ** PLEASE KNOW, PLANS ARE STILL ONLY | | | BEING SUBMITTED FOR "'PLAN REVIEW** AND | | | HAVE NOT BEEN SUBMITTED FOR PERMIT TO | | | DATE. | | | | | | | | | ** PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEW STILL APPLY. MOST WERE | | | ADDRESSED. | | | PLEASE KNOW, FS 553.80(2)(B) DOES NOT | | | APPLY AS PLANS HAVE NOT BEEN SUBMITTED | | | FOR PERMIT. | | | | | | | | | *** NOTES FOR ELECTRICAL ENGINEERING | | | FIRM WERE ADDRESSED AND ARE OK. | | | | | | 1) PLEASE SEE NEW NOTE #12 BELOW FROM | | | PREVIOUS REVIEW AS THE TITLE BLOCKS DO | | | NOT CONTAIN THE LICENSING INFORMATION | | | FOR THE ARCHITECT/ DESIGNER "TURNKEY | | | CONCEPTS" | | | PLEASE SEE FS 481.203, 481.223(1)(A), | | | AND 481.229 (1)(C). | | | PLEASE IF THIS IS INDEED A "DESIGN" | | | FIRM/OR "DRAFTING" FIRM, PLEASE KNOW IT | | | HAS BEEN CONFIRMED WITH THE STATE'S | | | LEGAL COUNSEL TO THE BOARD THAT THIS IS | | | PROHIBITED. | | | PLEASE KNOW, IF "TURNKEY" IS A LICENSED | | | ARCHITECTURAL FIRM OFFERING | | | ARCHITECTURAL SERVICES PLEASE INCLUDE | | | ALL INFORMATION ON TITLE BLOCKS AS | | | PREVIOUSLY REQUESTED. PLEASE KNOW A | | | SERCH ON THE STATE'S WEBSITE HAS NOT | | | COME UP WITH ANY INFORMATION ON SUCH | | | COMPANY FROM THE DEPARTMENT OF BUSINESS | | | AND PROFESSIONAL REGUALTION. | | | ONE COPY OF ALL SAID PLANS WILL BE | | | RETAINED AT THE REQUEST OF STATE'S | | | PROSECUTING ATTORNEY. | | | | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW ** | | | ************* NEW NOTE ************ | | | | | | | | | 12) NOTE: PLEASE SEE MISSING REQUIRED ON | | | TITLE BLOCKS FOR ARCHITECT AND FIRM AS | | | SHOWN. | | | PLEASE SEE FAC 61G1-16.004, AND FS | | | 481.219. | | | MISSING PRINTED NAME AND LICENSE #. | | | MISSING THE FIRM LICENSE #, ALSO KNOWN | | | AS THE CERTIFICATE OF AUTHORIZATION | | | NUMBER. | | | PLEASE KNOW, THIS IS REQUIRED ON ALL | | | SHEETS WHICH CONTAIN THIS TITLE BLOCK | | | AND WHICH ARE SIGNED, DATED AND SEALED | | | BY THE ARCHITECT. | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | ** PLEASE SEE ARCHITECT HAS NOT DATED | | | PLANS AS REQUIRED PER FS 481.221 | | | | | | ** PLEASE BE AWARE OF ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONLY ONE SET OF ANY OLD/VOIDED REMOVED | | | SHEETS NEED BE SUBMITTED BACK SEPARTELY | | | FOR REFERENCE. | | | | | | PLEASE SUBMITTHE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-30 |
Time |
21:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-30 |
Time |
21:24 |
Sent To |
|
|
| Notes |
| 2006-06-30 00:00:00 | *** UNSAT *** | | | | | | ** PLEASE KNOW, PLANS ARE STILL ONLY | | | BEING SUBMITTED FOR "'PLAN REVIEW** AND | | | HAVE NOT BEEN SUBMITTED FOR PERMIT TO | | | DATE. | | | | | | | | | ** PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEW STILL APPLY. MOST WERE | | | ADDRESSED. | | | PLEASE KNOW, FS 553.80(2)(B) DOES NOT | | | APPLY AS PLANS HAVE NOT BEEN SUBMITTED | | | FOR PERMIT. | | | | | | | | | | | | 1)NOTE:NO, PLEASE SEE PLANS/COVER | | | SHEETS REFLECTS THE 2004 FBC FOR THE | | | ELECTRICAL CODE. PLEASE REFERENCE THE | | | 2002 NFPA-70. | | | PLEASE ALSO SEE ENERGY CALCULATIONS ARE | | | STILL DESIGNED AND STATED PER 2001 FBC. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE PLANS REFERENCE THE | | | 2001 FBC AND OTHER CODES NO LONGER IN | | | AFFECT. PLEASE KNOW, THE NEW 2004 FBC | | | WAS ADOPTED ON OCT, 1ST, 2005. | | | PLEASE ALSO SEE OTHER CODES NOTES WHICH | | | ARE NO LONGER IN AFFECT. PLEASE | | | REFERENCE THE FOLLOWING | | | CODES. NFPA-70 2002, NFPA-101 2003, | | | NFPA-72 2002. | | | | | | | | | 2)NOTE:NO, PLEASE SEE THIS NOTE WAS | | | TYPED WITH THE "413" INSTEAD OF THE | | | "415". THIS WAS IN ERROROF THIS | | | OFFICE. THE NOTE WAS SHOWN ON PLANS FOR | | | THE RESPONSE FROM THE DESIGNER INSTEAD | | | OF OF PLACING ANY COMMENTS OR QUESTIONS | | | IN A RESPONSE LETTER? | | | PLEASE SEE THIS REQUIREMENT OF HAVING | | | THE LIGHTING CONTROLS DOES APPLY AS | | | STATED, IT IS IN A BUILDING LARGER THAN | | | 5K SQ FT. PLEASE SEE THAT THIS SPACE IS | | | A SEPARATELY METERED SPACE ON THIS SAME | | | ELECTRICAL SERVICE. | | | PLEASE SEE THAT THE TC PROVIDED IS OK, | | | HOWEVER AN OVER RIDE DEVICE IS REQUIRED | | | AT THE ENTRANCE(S) TO SPACE WHERE THE | | | OCCUPANT CAN READLITY SEE THE LIGHTING | | | BEING CONTROLLED. THIS OVERRIDE(S) | | | DEVICE IF TIMER CANE ONLY HAVE A SETTING | | | OF 4HRS. PLEASE SEE ANY SEPARATE SPACES | | | WITH FLR TO CEILING HEIGHT PARTITIONS | | | SHALL ALSO CONTAIN AN DEVICE OF SOME | | | SORT EITHER MOTION SENSOR, INFARED, | | | OCCUPANCY SENSOR ETC | | | PLEASE SEE 13-415.1.AB.1, 13-415.2.ABC.1 | | | WHICH REQUIRES THESE EVEN WHEN A | | | SEPARATELY METERED TENANT. | | | ** PLEASE KNOW, IF THIS TENANTS SPACE IS | | | LESS THAN 5% OF THE TOTAL "BUILDING" SQ | | | FOOTAGE THEN IT IS POSSIBLE THAT THIS | | | SPACE MAY MEET AN EXCEPTION. | | | ** PLEASE KNOW, THIS DOES NOT INCLUDE | | | ANY LIGHTING FOR EM/NIGHT LTS WHICH ARE | | | REQUIRED OR ON FOR "SAFETY". | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE FBC CHAPTER 13, | | | 13-413.1.ABC.1.1, & .2. | | | PLEASE PROVIDE SCHEDULING, CIRCUITING | | | AND SPACE CONTROL DEVICES FOR OVERIDES | | | AND SPACE CONTROL OVERIDE FOR SPACE. | | | | | | 3)NOTE: PLEASE SEE SEE ADDRESSING NEEDS | | | TO BE CORRECTED. PLEASE SEE PERMIT | | | APPLICATION MENTIONS 2060 ALONG WITH | | | PLANS, HOWEVER THE PCN USED FOR | | | APPLICATION CORRELATES TO OUR SYSTEM AND | | | PAPA AS 2000 PALM BEACH LAKES. PLEASE | | | SEE COMMENTS FROM ADDRESSING STOP AND | | | ADJUST PLANS WHEN NEEDED OR APPLICATION. | | | FAC 61G1-16.004 | | | | | | 4)NOTE:NO, PLEASE SEE ENERGY | | | CALCULATIONS STILL ARE SEALED WITH | | | "CERTIFICATE"?? PLEASE KNOW, THIS | | | PROJECT HAS NOT BEEN SUBMITTED FOR | | | PERMIT AND WAS NOT SUBMITTED FOR PERMIT | | | BEFORE THE DEC 31ST, 2005 DATE. | | | THEREFORE ALL SEALS MUST MEET THE | | | REQUIREMENTS AS STATED IN THE FAC AND FS | | | BELOW. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE ENERGY CALCUALTIONS | | | CONTAINS THE SEAL WHICH INDICATES | | | "CERTIFICATE" IN THE SAID SEAL OF THE | | | ENGINEER OF RECORD. PLEASE SEE FAC | | | 61G15-23.001 WHICH REQUIRED THE SEAL TO | | | CHANGE FROM "CERTIFICATE" TO "LICENSE" | | | AS OF FEB 5, 2004. PLEASE KNOW AND | | | EXTENSION WAS GRANTED TO THE FINAL DATE | | | OF 12/31/05. PLEASE KNOW, THE NEW SEAL | | | MUST BE USED. | | | ** PLANS ARE USING CORRECT SEAL. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: OK. | | | | | | 8) NOTE: OK. | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: OK. | | | | | | 11) NOTE:OK. | | | | | | ************* NEW NOTE ************ | | | | | | | | | 12) NOTE: PLEASE SEE MISSING REQUIRED ON | | | TITLE BLOCKS FOR ARCHITECT AND FIRM AS | | | SHOWN. | | | PLEASE SEE FAC 61G1-16.004, AND FS | | | 481.219. | | | MISSING PRINTED NAME AND LICENSE #. | | | MISSING THE FIRM LICENSE #, ALSO KNOWN | | | AS THE CERTIFICATE OF AUTHORIZATION | | | NUMBER. | | | PLEASE KNOW, THIS IS REQUIRED ON ALL | | | SHEETS WHICH CONTAIN THIS TITLE BLOCK | | | AND WHICH ARE SIGNED, DATED AND SEALED | | | BY THE ARCHITECT. | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES WHETHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWER(S). | | | ** PLEASE SEE ARCHITECT HAS NOT DATED | | | PLANS AS REQUIRED PER FS 481.221 | | | | | | ** PLEASE BE AWARE OF ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONLY ONE SET OF ANY OLD/VOIDED REMOVED | | | SHEETS NEED BE SUBMITTED BACK SEPARTELY | | | FOR REFERENCE. | | | | | | PLEASE SUBMITTHE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-29 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-29 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2006-03-29 00:00:00 | ***** UNSAT ******** | | | | | | ** PLEASE KNOW, PLANS WERE SUBMITTED FOR | | | "PLAN REVIEW" ONLY AND HAVE NOT BEEN | | | SUBMITTED FOR PERMIT. | | | | | | | | | 1)NOTE: PLEASE SEE PLANS REFERENCE THE | | | 2001 FBC AND OTHER CODES NO LONGER IN | | | AFFECT. PLEASE KNOW, THE NEW 2004 FBC | | | WAS ADOPTED ON OCT, 1ST, 2005. | | | PLEASE ALSO SEE OTHER CODES NOTES WHICH | | | ARE NO LONGER IN AFFECT. PLEASE | | | REFERENCE THE FOLLOWING | | | CODES. NFPA-70 2002, NFPA-101 2003, | | | NFPA-72 2002. | | | | | | | | | 2)NOTE: PLEASE SEE FBC CHAPTER 13, | | | 13-413.1.ABC.1.1, & .2. | | | PLEASE PROVIDE SCHEDULING, CIRCUITING | | | AND SPACE CONTROL DEVICES FOR OVERIDES | | | AND SPACE CONTROL OVERIDE FOR SPACE. | | | | | | 3)NOTE: PLEASE SEE SEE ADDRESSING NEEDS | | | TO BE CORRECTED. PLEASE SEE PERMIT | | | APPLICATION MENTIONS 2060 ALONG WITH | | | PLANS, HOWEVER THE PCN USED FOR | | | APPLICATION CORRELATES TO OUR SYSTEM AND | | | PAPA AS 2000 PALM BEACH LAKES. PLEASE | | | SEE COMMENTS FROM ADDRESSING STOP AND | | | ADJUST PLANS WHEN NEEDED OR APPLICATION. | | | FAC 61G1-16.004 | | | | | | 4)NOTE:PLEASE SEE ENERGY CALCUALTIONS | | | CONTAINS THE SEAL WHICH INDICATES | | | "CERTIFICATE" IN THE SAID SEAL OF THE | | | ENGINEER OF RECORD. PLEASE SEE FAC | | | 61G15-23.001 WHICH REQUIRED THE SEAL TO | | | CHANGE FROM "CERTIFICATE" TO "LICENSE" | | | AS OF FEB 5, 2004. PLEASE KNOW AND | | | EXTENSION WAS GRANTED TO THE FINAL DATE | | | OF 12/31/05. PLEASE KNOW, THE NEW SEAL | | | MUST BE USED. | | | ** PLANS ARE USING CORRECT SEAL. | | | | | | 5)NOTE: PLEASE LOAD CALCUALTIONS FOR | | | EXISTING SERVICE AND NEW LOADS ADDED TO | | | EXISTING. | | | 215.5, 220, | | | | | | 6) NOTE: PLEASE INDICATE ALL CONTINUOUS | | | LOADS AT 125%. | | | 215.3,230.42 | | | | | | 7) NOTE: PLEASE PROVIDE GFI PROTECTION | | | PER 2002 NEC, 210.8B3 | | | | | | 8) NOTE: PLEASE SUBMIT ALL AIC RATINGS | | | FOR ALL NEW MAINS/ SERVICE EQUIPMENT. | | | 110.9,215.5 | | | | | | 8)NOTE: PLEASE PROVIDE | | | NOTE/IDENTIFICATION OF "FEED-THRU" LUGS | | | IF INDEED THIS IS THE METHOD OF FEDDING | | | PANEL "B". | | | 215.5 | | | | | | 9) NOTE: PLEASE INDICATE THE | | | "FLOATING/ISOLATED" NEUTRAL IN METER AS | | | THIS LOCAITON IS NOT THE FIRST MEANS OF | | | DISCONNECT FOR SERVICE. | | | 250.6,250.24B | | | | | | 10) NOTE: PLEASE CLARIFY CIRCUTING, | | | PLEASE SEE SOME CIRCUITS DO NOT SEEM TO | | | CORRELATE WITH PLANS? | | | "SHOW WINDOWS?" | | | 215.5 | | | | | | 11) NOTE: PLEASE SEE 210.62, 220.12A FOR | | | MIN RECEPTS REQUIRED FOR WINDOW SPACING. | | | PLEASE SEE PLANS INDICATE A "SIGN" | | | ALREADY FOR THE WINDOW RECEPT AS | | | DEDICATED. ADDITIONAL RECEPTS WOULD BE | | | REQUIRED ALONG WITH ADDITIONAL RECEPTS | | | FOR THE LINEAR FT SHOWN MORE THAN 12'. | | | | | | ** PLEASE BE AWARE OF ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONLY ONE SET OF ANY OLD/VOIDED REMOVED | | | SHEETS NEED BE SUBMITTED BACK SEPARTELY | | | FOR REFERENCE. | | | | | | PLEASE SUBMITTHE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-01-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-03 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2007-01-03 10:42:52 | *****PROVISO***** | | | | | | | | | | | | PLEASE REFER TO BUILDING AND ELECTRICAL COMMENTS IN | | | REFERENCE TO THIS BEING A REVIEW FOR "PLAN CHECK" ONLY. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-24 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-24 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2006-10-24 14:04:55 | *****DENIED**** | | | | | | RESPONSES TO THE FIRE PLAN REVIEW COMMENTS OF 07/10/06 | | | RECEIVIED AS FOLLOWS: | | | | | | | | | 1.)OK | | | | | | 2.) OK | | | | | | 3.)PLEASE SHOW WHERE THIS COMMENT HAS BEEN | | | ACKNOWLEDGED. | | | | | | 4.)REVISE SO THAT DOORS DO NOT OPEN INTO THE EXIT | | | CORRIDOR.ALTHOUGH THE REAR DOOR IS READILY ACCESSABLE | | | TO EMPLOYEES, IT SHALL BE REQUIRED EXIT. | | | | | | 5.)PLEASE SHOW WHERE THIS COMMENT HAS BEEN | | | ACKNOWLEDGED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-10 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-10 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3. EXITS SHALL REMAIN CLEAR AND | | | ACCESSIBLE. | | | | | | 4. ONLY 14" REMAIN FOR EXIT ACCESS IN | | | THE REAR HALLWAY WHEN THE RESTROOM DOORS | | | ARE IN THE OPEN POSITION. THE RESTROOM | | | DOORS ARE 36" WIDE THAT OPEN ONTO A | | | CORRIDOR THAT IS 50" WIDE. PLEASE | | | REVISE. | | | | | | 5. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY REQUIRED HOOD, DUCT, AND | | | SUPPRESSION SYSTEMS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-20 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-20 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2006-04-20 00:00:00 | ******DENIED****** | | | PLAN REVIEW ONLY | | | | | | 1) BUILDING DATA INDICATES THAT BUILDING | | | IS NOT SPRINKLERED, BUT RESPONSIBILITY | | | SCHEDULE INDICATES SPRINKLER SYSTEM. | | | PLEASE CLARIFY. | | | | | | 2) PLEASE INDICATE MINIMUM INTERIOR | | | FINISH CLASSIFICATION FOR WALLS AND | | | CEILING IN TERMS OF CLASS A,B ORC. | | | | | | 3) 2A-10B,C RATED FIRE EXTINGUISHER(S) | | | REQUIRED AND SHALL BE MOUNTED AT | | | DISTANCES NOT TO EXCEED 75' TRAVEL | | | DISTANCE REQUIREMENT. "K" TYPE | | | EXTINGUISHER REQUIRED IN KITCHEN. | | | | | | 4) PLEASE SEE ELECTRICAL REVIEW COMMENT | | | REGARDING CODE EDITIONS AND MAKE | | | APPROPRIATE CORRECTIONS. NFPA 101 AND | | | NFPA 1, 2003 EDITIONS. | | | | | | 5) IF NO FIRE ALARM SYSTEM, HOOD | | | SUPPRESSION WILL BE REQUIRED TO DISPLAY | | | OCCUPANT NOTIFICATION BY WAY OF | | | AUDIBLE/VISUAL DEVICE. SYSTEM TO BE TIED | | | INTO FIRE ALARM SYSTEM IF APPLICABLE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-08-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-06 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-06 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2006-08-06 00:00:00 | PROVISO: EMERGENCY SOV, NOT UNDER HOOD. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-06 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-06 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2006-05-06 00:00:00 | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | | | | UNSAT | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304 | | | . | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | 10)EMERGENCY HOOD SHUT OFF VALVE | | | (E) AUTOMATIC SHUT OFF VALVE. | | | NFPA-96 SEC 10.5.1, NFPA-1 SEC 50.4/7.1 | | | GAS EMERGENCY SOV TO BE 42" TO 48" AFF | | | | | | QUESTIONS 561-805-6692PAUL SCHMITZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-10 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-10 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2007-01-10 10:03:07 | WAITING FOR "COMM" BD--PROJ TO PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-13 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-13 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2006-11-15 10:56:39 | TO "COMM" BD#61 | | 2006-11-13 08:36:34 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2006-10-01 00:00:00 | TO COMM BOARD #47 | | 2006-09-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | TO "COMM" BD#12 | | 2006-06-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
20:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
20:00 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | TO COMM BOARD # 52, B |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-08 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-02-28 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2006-02-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-12 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-12 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2006-12-12 09:21:22 | PASS PRIVISO | | | ACCORDING TO INSTALLATION INSTRUCTIONS THE ROOF TOP | | | PACKAGE UNIT WILL PROVIDE UP TO 2,400 CFM. THE DESIGN | | | CAPACITY OF THE UNIT IS GREATER THAN 2000 CFM, SO FAN | | | SHUTDOWN IS REQUIRED. SECTION 606.2.1 2001 FBC (M) . | | | ADDITIONAL PLANS AND PERMITS REQUIRED FOR HOOD,COOLERS | | | AND SUPPRESSION. | | | PLEASE REFER TO SECTION 606.4.1 SUPERVISION. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | 2006-11-28 20:06:31 | NEW SHEETS/INFORMATION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-23 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-23 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2006-10-23 15:15:53 | MECHANICAL PLANS WERE PASED ON 7/24/06 YOU MUST COMPLI | | | WITH PERVISO . | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-07-24 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-07-24 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2006-07-24 00:00:00 | PASS PROVISO | | | 1) PLEASE REFER TO SECTION 606.2.1 SNOKE | | | DETECTION SYSTEMS CONTROL AND 606.4.1 | | | SUPERVISON. 2004 FBC.(M) | | | 2) PLEASE SUBMIT PLANS AND HANGING | | | DETAIL WITH THE HOOD PERMIT APPLICATION | | | 3) PLEASE SUBMIT A COPY OF MANUFACTURERS | | | INSTALLATION INSTRUCTIONS FOR WALK IN | | | COOLERS WITH PERMIT APPLICATION. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-04-03 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-04-03 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-04-03 00:00:00 | PLAN DENIED | | | 1) PLEASE PROVIDE A COPY OF | | | MANUFACTURERS INSTALLATION INSTRUCTIONS | | | OF A/C EQUIPMENT WITH PLANS. | | | 2) PLEASE REFER TO SECTION 606 AND | | | 606.4.1 2004 FBC(M) | | | 3) ADDITIONAL PERMITS REQUIRED FOR WALK | | | IN COOLERS,HOOD,HOOD SUPPRESSION. | | | 4) PLEASE PRINT NAME AND PROVIED A | | | SIGNATURE OF ARCHITTECT ON THE PLANS | | | SECTION 106.3.4.3 ADMINISTRATION 2004 | | | EDITION FBC | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-12-02 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-12-02 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2006-12-02 12:28:17 | DBPR AND GREASE TRAP APPROVALSIZE ARE NOW ATTACHERD | | | TO THE PLANS AS PREVIOUSLY REQUESTED.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-24 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-24 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2006-10-24 10:32:11 | REFERENCE: FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | DENIED | | | | | | A. FROM PREVIOUS REVIEW: | | | | | | 2) SHT P-2 PLANS SHALL BE ROUTED TO DBPR, BUSINESS & | | | HOTEL DIVISION FOR REVIEW. MINIMUM 2 SETS OF PLANS | | | SHALL BE REVIEWED AND STAMPED. THE TWO PAGE | | | "WORKSHEETS" SHALL BE ATTACHED TO EACH SET OF PLANS | | | PRIOR TO RESUBMITTING TO THE CITY OF WEST PALM BEACH | | | FOR REVIEW. PLEASE CONTACT DBPR AT (850) 487-1395. | | | | | | SPECIFICATION WORKSHEET FROM DBPR AND STAMPED PLANS ARE | | | REQUIRED BEFORE PLUMBING PLAN REVIEW CAN BE APPROVED. | | | | | | **************NEW COMMENT************** | | | | | | 1B. SEE ELECTRICAL PLAN REVIEW CONCERNING MISSING | | | INFORMATION IN THE TITLE BLOCKS OF THE DESIGN | | | PROFESSIONAL. ALSO SEE ELECTRICAL REVIEW COMMENTS | | | CONCERNING "DESIGN FIRMS", ARCHITECTURAL BUSINESS | | | LICENSE NUMBERS ETC. PER FAC 61G1-16.004(2) AND FS | | | 481.203, 481.223(1)(A), 481.229(1)(C), AND 481.219. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-06 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-06 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2006-08-06 00:00:00 | | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | UNSAT | | | | | | PREVIOUS NOTES NOT ADDRESED | | | | | | 2) SHT P-2 PLANS SHALL BE ROUTED TO DBPR | | | BUSINESS AND HOTEL DIVISION FOR | | | REVIEW. MINIMUM 2 SETS OF PLANS | | | SHALL BE REVIEWED AND STAMPED | | | AND THE TWO PAGE ?WORKSHEETS? | | | ATTACHED TO EACH SET OF PLANS | | | PRIOR TO RESUBMITTING TO CITY OF WEST | | | PALM BEACH | | | FOR REVIEW. PLEASE CONTACT DBPR | | | AT (850) 487-1395. | | | | | | SPECIFICATION WORKSHEET FROM DBPR AND | | | STAMPED PLANS ARE REQUIRED BEFORE | | | PLUMBING PLAN REVIEW CAN BE APPROVED. | | | | | | END OF COMMENTS,QUESTIONS 561 805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-06 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-06 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2006-05-06 00:00:00 | | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | UNSAT | | | | | | 1) SHT P-2 GRASE TRAP TO BE SIZED BY | | | W P BEACHWATERPLANT LAB SUPERVISOR | | | INDUSTRIAL COORDINATOR, LYNN MASSON | | | OFFICE 561-822-2271 | | | E-MAIL [email protected] | | | | | | 2) SHT P-2 PLANS SHALL BE ROUTED TO DBPR | | | BUSINESS AND HOTEL DIVISION FOR | | | REVIEW. MINIMUM 2 SETS OF PLANS | | | SHALL BE REVIEWED AND STAMPED | | | AND THE TWO PAGE ?WORKSHEETS? | | | ATTACHED TO EACH SET OF PLANS | | | PRIOR TO RESUBMITTING TO CITY OF WEST | | | PALM BEACH | | | FOR REVIEW. PLEASE CONTACT DBPR | | | AT (850) 487-1395. | | | | | | 3) SHT A-1.0 REST ROOMS DOORS | | | 11-4.22.2 DOORS.ALL DOORS TO ACCESSIBLE | | | TOILET ROOMS SHALL COMPLY WITH SECTION | | | 11-4.13. DOORS SHALL NOT SWING INTO THE | | | CLEAR FLOOR SPACE REQUIRED FOR ANY | | | FIXTURE. | | | | | | 4)SHT P-3 GAS RISER DIAGRAM | | | SEE GAS PLAN REVIEW COMMENTS. | | | | | | 5) SHT P-3 PLUMBING SPECIFICATIONS NOTE | | | (8)REFERENCE TO AIR CHAMBERS PROVIDE A | | | DETAIL COMPLYING WITH PRI STD-WH 201 | | | ALL AIR CHAMBERS SHALL BE ACCESSIBLE. | | | | | | 6) SHT P-2 WATER HEATER | | | 607.3 THERMAL EXPANSION CONTROL. | | | A MEANS OF CONTROLLING INCREASED | | | PRESSURE CAUSED BY THERMAL EXPANSION | | | SHALL BE PROVIDED WHERE REQUIRED IN | | | ACCORDANCE WITH SECTIONS 607.3.1 AND | | | 607.3.2. | | | 607.3.2 BACKFLOW PREVENTION DEVICE OR | | | CHECK VALVE. | | | WHERE A BACKFLOW PREVENTION DEVICE, | | | CHECK VALVE OR OTHER DEVICE IS INSTALLED | | | ON A WATER SUPPLY SYSTEM UTILIZING | | | STORAGE WATER HEATING EQUIPMENT SUCH | | | THAT THERMAL EXPANSION CAUSES AN | | | INCREASE IN PRESSURE, A DEVICE FOR | | | CONTROLLING PRESSURE SHALL BE INSTALLED. | | | | | | 7) SHT P-3 WATER RISER | | | 604.9 WATER HAMMER. | | | THE FLOW VELOCITY OF THE WATER | | | DISTRIBUTION SYSTEM SHALL BE CONTROLLED | | | TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE | | | INSTALLED WHERE QUICK-CLOSING VALVES ARE | | | UTILIZED. WATER-HAMMER ARRESTORS SHALL | | | BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER?S SPECIFICATIONS. | | | WATER-HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010. | | | SHALL BE INSTALLED BETWEEN THE LAST TWO | | | FIXTURES, NOT AT THE TOP OF THE RISER. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|