Plan Review Details - Permit 06021008
Plan Review Stops For Permit 06021008
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-20 Cont ID  
Sent By alange Date 2006-07-20 Time 09:39 Rev Time 0.75
Received By alange Date 2006-07-20 Time 09:26 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-29 Cont ID  
Sent By alange Date 2006-03-29 Time 11:41 Rev Time 0.75
Received By alange Date 2006-03-29 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-07-14 Cont ID  
Sent By btrobaug Date 2006-07-14 Time 19:58 Rev Time 0.33
Received By btrobaug Date 2006-07-14 Time 19:42 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-05-24 Cont ID  
Sent By btrobaug Date 2006-05-24 Time 07:53 Rev Time 1.00
Received By btrobaug Date 2006-05-24 Time 06:15 Sent To P
Notes
2006-05-24 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE IS NO FEEDER SHOWN FROM THE
 METER TO THE PIECE OF EQUIPMENT MARKED
 "WP NEW" ON THE RISER. INDICATE ALL
 CONDUIT AND CONDUCTOR TYPES AND SIZES
 PER 215.5.
  
 2} DESIGNATE ALL SERVICE EQUIPMENT. THE
 PANEL AT THE PROPOSED SHED IS LABLED
 "A", BUT NO PANEL "A" APPEARS ON THE
 RISER DIAGRAM.
  
 3} SHOW THE LOCATION OF ALL EQUIPMENT
 INDICATED ON THE RISER, ON THE PLAN.
  
 4} PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 5} 210.8(A)(2)GARAGES, AND ALSO
 ACCESSORY BUILDINGS THAT HAVE A FLOOR
 LOCATED AT OR BELOW GRADE LEVEL NOT
 INTENDED AS HABITABLE ROOMS AND LIMITED
 TO STORAGE AREAS, WORK AREAS, AND AREAS
 OF SIMILAR USE
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-03-09 Cont ID  
Sent By btrobaug Date 2006-03-09 Time 14:54 Rev Time 0.33
Received By btrobaug Date 2006-03-09 Time 14:22 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-07-12 Cont ID  
Sent By adarroug Date 2006-07-12 Time 14:20 Rev Time 0.00
Received By adarroug Date 2006-07-12 Time 14:20 Sent To E
Notes
2006-07-12 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 16:05 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 16:05 Sent To E
Notes
2006-05-22 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-05 Cont ID  
Sent By adarroug Date 2006-05-05 Time 13:41 Rev Time 0.00
Received By adarroug Date 2006-05-05 Time 13:41 Sent To Z
Notes
2006-05-05 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-07 Cont ID  
Sent By adarroug Date 2006-03-07 Time 11:42 Rev Time 0.00
Received By adarroug Date 2006-03-07 Time 11:42 Sent To E
Notes
2006-03-07 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-29 Cont ID  
Sent By alange Date 2006-03-29 Time 11:41 Rev Time 0.00
Received By alange Date 2006-02-24 Time 10:07 Sent To  
Notes
2006-02-24 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-07-18 Cont ID  
Sent By jleech Date 2006-07-18 Time 13:49 Rev Time 0.00
Received By jleech Date 2006-07-18 Time 13:49 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-06-05 Cont ID  
Sent By jleech Date 2006-06-05 Time 14:43 Rev Time 0.00
Received By jleech Date 2006-06-05 Time 14:43 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-13 Cont ID  
Sent By jleech Date 2006-03-13 Time 13:48 Rev Time 0.00
Received By jleech Date 2006-03-13 Time 13:48 Sent To B
Notes
2006-03-13 00:00:00DENIED;
 1.PLEASE PROVIDE MANUFACTURES
 SPECIFICATIONS FOR LITTLE GIANT WASTE
 PUMP.
 2.SHOW LOCATION OF SINK AND FLOOR DRAIN
 ON FLOOR PLAN.
 3.VENT REQUIRED ON LITTLE GIANT ALSO A
 CHECK VAVLE SHUTOFF VALVE AND A UNION
 ARE REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2006-07-21 Cont ID  
Sent By mmclean Date 2006-07-21 Time 16:06 Rev Time 0.00
Received By mmclean Date 2006-07-21 Time 16:06 Sent To  
Notes
2006-07-21 00:00:00NEW SHEET - RESUB.
 PROVISO: THE NEW ELECTRICAL SERVICE MUST
 BE REMOVED, SF7, PROPOSED SHED CANNOT BE
 USED AS A LIVING SPACE. SHED CANNOT BE
 BUILT IN THE 5FT U.E.
 RESUB - NEW SHEETS.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-05-22 Cont ID  
Sent By mmclean Date 2006-05-22 Time 11:26 Rev Time 0.00
Received By mmclean Date 2006-05-22 Time 11:26 Sent To I
Notes
2006-05-22 00:00:00PROVISO: THE NEW ELECTRICAL SERVICE MUST
 BE REMOVED, SF7, PROPOSED SHED CANNOT BE
 USED AS A LIVING SPACE. SHED CANNOT BE
 BUILT IN THE 5FT U.E.
 RESUB - NEW SHEETS.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-03-06 Cont ID  
Sent By mmclean Date 2006-03-06 Time 11:56 Rev Time 0.00
Received By mmclean Date 2006-03-06 Time 11:56 Sent To I
Notes
2006-03-06 00:00:00PROVISO: THE NEW ELECTRICAL SERVICE MUST
 BE REMOVED, SF7, PROPOSED SHED CANNOT BE
 USED AS A LIVING SPACE. SHED CANNOT BE
 BUILT IN THE 5FT U.E.