| Plan Review Stops For Permit 06020892 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-27 |
Time |
11:53 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-04-27 |
Time |
10:41 |
Sent To |
E |
|
| Notes |
| 2006-04-27 00:00:00 | | | | | | | TOM GORDON IS WALKING PLANS THROUGH SEND | | | TO ELEC |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-04-25 |
Time |
16:44 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-04-25 |
Time |
16:44 |
Sent To |
PC |
|
| Notes |
| 2006-04-25 00:00:00 | | | | | | | DENIED | | | | | | 1) ONLY 2 PRODUCT APPROVALS WERE | | | APPROVED BY DESIGNER OF RECORD. PLEASE | | | STAMP ALL COPIES OF ALL PRODUCTS | | | | | | 2) PRODUCT APPROVALS WERE SUBMITTED FOR | | | STORM PANELS. PLEASE SPECIFY WHERE THEY | | | ARE TO BE USED AS THE WINDOWS DO NOT | | | REQUIRE THEM BECAUSE PRODUCT APPROVALS | | | ARE FOR IMPACT WINDOWS. PLEASE CLARIFY | | | | | | 3) WE REQUIRE 2 COPIES OF ALL SUBMITTALS | | | THIS INCLUDES ENERGY CALC'S AND MANUAL | | | J,S (SEE MECHANICAL NOTES) | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-03-28 |
Time |
16:14 |
Rev Time |
2.00 |
| Received By |
amorse |
Date |
2006-03-28 |
Time |
16:14 |
Sent To |
PC |
|
| Notes |
| 2006-03-28 00:00:00 | | | | | | | DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | | | | 2) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* THE VALUE HAS BEEN ADJUSTED | | | AND FEE ARE DUE | | | | | | 3) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE | | | | | | 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | | APPLICATION OR BEFORE INSTALLATION | | | | | | 5) THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 6) AMEND DRAWINGS TO COMPLY WITH THE | | | DESIGN PARAMETERS FROM 1609 AND | | | ASCE 7-02 | | | | | | 7) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | | | | | | | 8) PRODUCT APPROVAL NOA'S FOR SHINGLES | | | ARE OUTDATED PLEASE SUBMIT NEW NOA'S | | | | | | * WEST PALM BEACH ADMINISTRATIVE AMMEND. | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-21 |
Time |
13:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-21 |
Time |
12:25 |
Sent To |
B |
|
| Notes |
| 2006-04-25 00:00:00 | | | | ENGINEER MUST COMPLY WITH 16G15-23.002 | | | FAC. | | | | | | THE ELECTRICAL PLAN IS O.K. PLEASE | | | RESUBMIT AFTER ENGINEER CORRECTS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-13 |
Time |
10:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-13 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE THE AIC RATING OF THE | | | EQUIPMENT PER 110.9 & 110.10. | | | | | | 2} THE CURRENT NEC CYCLE IS 2002. SEE | | | NOTE #1. | | | | | | 3} BEDROOMS 1,3,4 AND LIVING ROOM NEED | | | RECEPTACLES ADDED TO COMPLY WITH | | | 210.52(A)(1)&(2). SEE REVIEWED SET OF | | | PLANS. | | | | | | 4} THE RECEPTACLE ON THE KITCHEN ISLAND | | | MUST COMPLY WITH 210.8(A)(6) | | | | | | 5} A RECEPTACLE MUST BE LOCATED OUTSIDE | | | AT THE FRONT OF THE RESIDENCE TO COMPLY | | | WITH 210.52(E). | | | | | | 6} THE OCP FOR THE AHU @ 80 (CIRCUIT | | | 1/3), IS TOO LARGE FOR THE #6 CONDUCTOR, | | | SEE 210.16. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-17 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-17 |
Time |
15:52 |
Sent To |
E |
|
| Notes |
| 2006-04-17 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
11:24 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-03-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-22 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-27 |
Time |
11:08 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-04-27 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2006-04-27 00:00:00 | MECHANICAL PLANS REMOVED AND WILL APPLY | | | FOR MECH. LATER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-25 |
Time |
12:53 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-04-25 |
Time |
08:49 |
Sent To |
E |
|
| Notes |
| 2006-04-25 00:00:00 | *** DENIED *** | | | 1) ENGINEER'S NAME, ADDRESS, AND LICENSE | | | NUMBER MUST BE LEGIBLY INDICATED ON ALL | | | PLANS THAT HAVE HIS SEAL ON THEM, PER | | | FAC 61G15-23.002 . | | | | | | 2) RETURN AIR DUCTS TO BEDROOMS DO NOT | | | RETURN TO TRUNK LINE OR A/C UNIT PLEASE | | | CORRECT. | | | | | | 3) RETURN AIR TRUNK LINE TO AIR HANDLER | | | UNIT IS NOT SIZED. | | | | | | 4) MANUAL J CAL'S. ARE SHOWING 110 | | | CFM'S. TO EACH AND EVERY ROOM REGARDLESS | | | OF ROOM SIZE PLEASE CORRECT. | | | | | | 5) MANUAL J CAL'S. DO NOT SHOW NAME OF | | | ROOMS AND NEED TO. | | | | | | 6) MECHANICAL PLANS CFM'S. TO EACH ROOM | | | AND MANUAL J CAL'S. CFM'S. TO EACH ROOM | | | DO NOT MATCH PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-13 |
Time |
10:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-03-13 |
Time |
10:50 |
Sent To |
P |
|
| Notes |
| 2006-03-13 00:00:00 | *** DENIED *** | | | 1) NEED TO SUBMIT A NEW MANUAL J (LONG | | | FORM) FOR THE ENTIRE HOUSE, SHOWING | | | CFM'S FOR EACH ROOM. | | | | | | 2) NEED TO SHOW ALL DUCT SIZES, GRILL | | | SIZES, AND CFM'S ON MECHANICAL PLANS. | | | | | | 3) PLEASE SHOW CLOTHS DRYER VENT ON | | | MECHANICAL PLANS. | | | | | | 4) PLEASE PROVIDE RETURN AIR TO ALL | | | BEDROOMS SEE NOTE #5. | | | | | | 5)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-13 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-13 |
Time |
13:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-08 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-08 |
Time |
17:20 |
Sent To |
I |
|
| Notes |
|
|