Plan Review Details - Permit 06020892
Plan Review Stops For Permit 06020892
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-04-27 Cont ID  
Sent By btrobaug Date 2006-04-27 Time 11:53 Rev Time 0.50
Received By amorse Date 2006-04-27 Time 10:41 Sent To E
Notes
2006-04-27 00:00:00 
  
 TOM GORDON IS WALKING PLANS THROUGH SEND
 TO ELEC

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-04-25 Cont ID  
Sent By amorse Date 2006-04-25 Time 16:44 Rev Time 0.50
Received By amorse Date 2006-04-25 Time 16:44 Sent To PC
Notes
2006-04-25 00:00:00 
  
 DENIED
  
 1) ONLY 2 PRODUCT APPROVALS WERE
 APPROVED BY DESIGNER OF RECORD. PLEASE
 STAMP ALL COPIES OF ALL PRODUCTS
  
 2) PRODUCT APPROVALS WERE SUBMITTED FOR
 STORM PANELS. PLEASE SPECIFY WHERE THEY
 ARE TO BE USED AS THE WINDOWS DO NOT
 REQUIRE THEM BECAUSE PRODUCT APPROVALS
 ARE FOR IMPACT WINDOWS. PLEASE CLARIFY
  
 3) WE REQUIRE 2 COPIES OF ALL SUBMITTALS
 THIS INCLUDES ENERGY CALC'S AND MANUAL
 J,S (SEE MECHANICAL NOTES)
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-28 Cont ID  
Sent By amorse Date 2006-03-28 Time 16:14 Rev Time 2.00
Received By amorse Date 2006-03-28 Time 16:14 Sent To PC
Notes
2006-03-28 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC* THE VALUE HAS BEEN ADJUSTED
 AND FEE ARE DUE
  
 3) THE STATE OF FLORIDA REQUIRES
 COLLECTION OF A RADON SURCHARGE ON ALL
 NEW CONSTRUCTION COMPUTED ON UNDER ROOF
 FLOOR SPACE
  
 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6) AMEND DRAWINGS TO COMPLY WITH THE
 DESIGN PARAMETERS FROM 1609 AND
 ASCE 7-02
  
 7) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
  
  
 8) PRODUCT APPROVAL NOA'S FOR SHINGLES
 ARE OUTDATED PLEASE SUBMIT NEW NOA'S
  
 * WEST PALM BEACH ADMINISTRATIVE AMMEND.
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-27 Cont ID  
Sent By btrobaug Date 2006-04-21 Time 13:13 Rev Time 0.50
Received By btrobaug Date 2006-04-21 Time 12:25 Sent To B
Notes
2006-04-25 00:00:00 
 ENGINEER MUST COMPLY WITH 16G15-23.002
 FAC.
  
 THE ELECTRICAL PLAN IS O.K. PLEASE
 RESUBMIT AFTER ENGINEER CORRECTS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-13 Cont ID  
Sent By btrobaug Date 2006-03-13 Time 10:10 Rev Time 0.50
Received By btrobaug Date 2006-03-13 Time 06:51 Sent To  
Notes
2006-03-13 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INDICATE THE AIC RATING OF THE
 EQUIPMENT PER 110.9 & 110.10.
  
 2} THE CURRENT NEC CYCLE IS 2002. SEE
 NOTE #1.
  
 3} BEDROOMS 1,3,4 AND LIVING ROOM NEED
 RECEPTACLES ADDED TO COMPLY WITH
 210.52(A)(1)&(2). SEE REVIEWED SET OF
 PLANS.
  
 4} THE RECEPTACLE ON THE KITCHEN ISLAND
 MUST COMPLY WITH 210.8(A)(6)
  
 5} A RECEPTACLE MUST BE LOCATED OUTSIDE
 AT THE FRONT OF THE RESIDENCE TO COMPLY
 WITH 210.52(E).
  
 6} THE OCP FOR THE AHU @ 80 (CIRCUIT
 1/3), IS TOO LARGE FOR THE #6 CONDUCTOR,
 SEE 210.16.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-17 Cont ID  
Sent By adarroug Date 2006-04-17 Time 15:52 Rev Time 0.00
Received By adarroug Date 2006-04-17 Time 15:52 Sent To E
Notes
2006-04-17 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 11:24 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 11:24 Sent To E
Notes
2006-03-09 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-03-28 Time   Rev Time 0.00
Received By adarroug Date 2006-02-22 Time 16:47 Sent To  
Notes
2006-02-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2006-04-27 Cont ID  
Sent By tgordon Date 2006-04-27 Time 11:08 Rev Time 0.30
Received By tgordon Date 2006-04-27 Time 11:08 Sent To  
Notes
2006-04-27 00:00:00MECHANICAL PLANS REMOVED AND WILL APPLY
 FOR MECH. LATER.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-04-25 Cont ID  
Sent By btrobaug Date 2006-04-25 Time 12:53 Rev Time 1.00
Received By tgordon Date 2006-04-25 Time 08:49 Sent To E
Notes
2006-04-25 00:00:00*** DENIED ***
 1) ENGINEER'S NAME, ADDRESS, AND LICENSE
 NUMBER MUST BE LEGIBLY INDICATED ON ALL
 PLANS THAT HAVE HIS SEAL ON THEM, PER
 FAC 61G15-23.002 .
  
 2) RETURN AIR DUCTS TO BEDROOMS DO NOT
 RETURN TO TRUNK LINE OR A/C UNIT PLEASE
 CORRECT.
  
 3) RETURN AIR TRUNK LINE TO AIR HANDLER
 UNIT IS NOT SIZED.
  
 4) MANUAL J CAL'S. ARE SHOWING 110
 CFM'S. TO EACH AND EVERY ROOM REGARDLESS
 OF ROOM SIZE PLEASE CORRECT.
  
 5) MANUAL J CAL'S. DO NOT SHOW NAME OF
 ROOMS AND NEED TO.
  
 6) MECHANICAL PLANS CFM'S. TO EACH ROOM
 AND MANUAL J CAL'S. CFM'S. TO EACH ROOM
 DO NOT MATCH PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-03-13 Cont ID  
Sent By tgordon Date 2006-03-13 Time 10:50 Rev Time 0.30
Received By tgordon Date 2006-03-13 Time 10:50 Sent To P
Notes
2006-03-13 00:00:00*** DENIED ***
 1) NEED TO SUBMIT A NEW MANUAL J (LONG
 FORM) FOR THE ENTIRE HOUSE, SHOWING
 CFM'S FOR EACH ROOM.
  
 2) NEED TO SHOW ALL DUCT SIZES, GRILL
 SIZES, AND CFM'S ON MECHANICAL PLANS.
  
 3) PLEASE SHOW CLOTHS DRYER VENT ON
 MECHANICAL PLANS.
  
 4) PLEASE PROVIDE RETURN AIR TO ALL
 BEDROOMS SEE NOTE #5.
  
 5)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-03-13 Cont ID  
Sent By jleech Date 2006-03-13 Time 13:37 Rev Time 0.00
Received By jleech Date 2006-03-13 Time 13:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-03-08 Cont ID  
Sent By mmclean Date 2006-03-08 Time 17:20 Rev Time 0.00
Received By mmclean Date 2006-03-08 Time 17:20 Sent To I
Notes
***NONE***