| Plan Review Stops For Permit 06020842 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-10 |
Time |
13:22 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-04-10 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
14:42 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2006-03-13 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.CONSTRUCTION TYPE IS NOT CORRECT. | | | TYPE 6 NO LONGER EXISTS UNDER THE 2004 | | | FBC.SHOULD BE 5A OR 5B. | | | | | | 3.ENERGY CALCS SUBMITTED SHALL BE TO | | | THE 2004 FBC | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR STRAPS, | | | TIEDOWNS AND SMALL OVERHEAD GARAGE DOOR | | | WITH THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUATION HAS BEEN INCREASED | | | TO $371,909.00ADDITIONAL PERMIT FEES | | | ARE DUE. | | | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | 7.TRUSS DRAWINGS ARE REQUIRD FOR PLAN | | | REVIEW PRIOR TO INSTALLATION AND SHALL | | | COMPLY WITH, R-802.10.1. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-13 |
Time |
07:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-13 |
Time |
07:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-05 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-05 |
Time |
14:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-24 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-24 |
Time |
07:37 |
Sent To |
M |
|
| Notes |
| 2006-02-24 00:00:00 | ******** UNSAT ********** | | | | | | 1)NOTE: PLEASE CORRELATE PANEL "A' WITH | | | RISER ETC AS NOTE ON PANEL "A" MENTIONS | | | TO BE 200A, YET RISER SHOWS THIS A 150A? | | | | | | 2)NOTE: PLEASE SEE MIN SIZE GROUNDING | | | ELECTRODE CONDUCTOR SHALL BE 1/0, NOT #1 | | | ASSHOWN. | | | 250.66,310.15B6 | | | ** PLEASE KNOW, GROUNDING ELECTRODE IS | | | SHOWN GOING TO CWP, HOWEVER THIS IS | | | NOTED AS PVC? | | | | | | 3)NOTE: PLEASE SEE SD REFERENCES THE | | | WRONG CHAPTER, AS THE NFPA-72 UNDER | | | CURRENT AOPTION IS THE 2002 -720, PLEASE | | | KNOW, THIS WAS OF JAN 1ST, 2005. | | | PLEASE SEE CHAPTER 11, UNDER THE 2002 | | | NFPA-72. | | | | | | 4)NOTE: PLEASE SEE DISHWASHER IS BEING | | | SHOWN AS A 2POLE/240V UNIT? PLEASE | | | VERIFY AS RECEPTS ON PLANS SEEM TO | | | INDICATE A DISPOSAL, YET PANEL SCHEDULE | | | DOES NOT SHOW THIS. | | | PLEASE VERIFY AND CORRELATE. | | | | | | 5)NOTE: PLEASE SEE THREE CU'S ON PLANS, | | | YET ONLYTWO DISC'S SHOWN. | | | 440.11 | | | | | | 6)NOTE: PLEASE SEE REDLINED MISSING | | | RECEPTS PER 210.52, LIV RM, BEDRM #3. | | | | | | 7)NOTE: PLEASE SEE 2KW LOAD FROM HI-HATS | | | IS BEING SHOWN ON ONE CIRCUIT. PLEASE | | | KNOW THE LOAD FOR A 15A CIRCUIT IS | | | 1440VA. | | | | | | ** PLEASE REMOVE ANY OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-19 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-19 |
Time |
14:42 |
Sent To |
P |
|
| Notes |
| 2006-12-19 14:44:24 | TO "P" BOX/ REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-04 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-04 |
Time |
13:56 |
Sent To |
E |
|
| Notes |
| 2006-04-04 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-02-19 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2006-02-19 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-07 |
Time |
08:06 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-04-07 |
Time |
08:06 |
Sent To |
B |
|
| Notes |
| 2006-04-07 00:00:00 | CUSTOMER VOIDED MECH. PERMIT #06020853. | | | NO MECHANICAL PLANS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-28 |
Time |
08:47 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-02-28 |
Time |
08:47 |
Sent To |
P |
|
| Notes |
| 2006-02-28 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PERMIT APPLIED FOR BUT NO | | | MECHANICAL PLANS SUBMITTED. PLEASE | | | SUBMIT MECHANICAL PLANS FOR REVIEW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-28 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-28 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2006-12-28 12:57:20 | PLUMBING RISER REVISED ADDED SINK ON PORCH. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-01 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-01 |
Time |
07:32 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-23 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-23 |
Time |
13:20 |
Sent To |
E |
|
| Notes |
|
|