| Plan Review Stops For Permit 06020840 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-19 |
Time |
14:40 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-04-19 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2006-04-14 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.CONSTRUCTION TYPE IS NOT CORRECT. | | | TYPE 6 NO LONGER EXISTS UNDER THE 2004 | | | FBC.SHOULD BE 5A OR 5B. | | | | | | 3.ENERGY CALCS SUBMITTED SHALL BE TO | | | THE 2004 FBC | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR STRAPS, | | | TIEDOWNS AND LINTELS WITH THE FOLLOWING | | | STATE PRODUCT APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUATION HAS BEEN INCREASED | | | TO $286,828.00ADDITIONAL PERMIT FESS | | | ARE DUE. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-23 |
Time |
20:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-23 |
Time |
19:39 |
Sent To |
PC |
|
| Notes |
| 2006-10-23 20:13:51 | RE- STAMP ONLY, | | | | | | | | | REDLINED SAME ITEMS FROM PREVIOUS REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-20 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-20 |
Time |
13:05 |
Sent To |
PC |
|
| Notes |
| 2006-08-20 00:00:00 | REDLINED, VIF THE OCP AND WIRE SIZES | | | FOR AHU#2, | | | | | | REDLINED, 2002 NEC. | | | | | | REDLINED NFPA-2002, CHAPTER 11, AS PLANS | | | NOTE THE 1999 NFPA-CHAPTER 8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-24 |
Time |
09:55 |
Sent To |
M |
|
| Notes |
| 2006-02-24 00:00:00 | REDLINED WRONG CODE/CHAPTER FOR NFPA-72. | | | | | | REDLINED MORE THAN ONE CIRCUIT FOR | | | HI-HATS, AS ALL ARE SHOWN ON ONE | | | CIRCUIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-23 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-23 |
Time |
11:49 |
Sent To |
E |
|
| Notes |
| 2006-10-23 11:50:00 | TO "DPALMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
11:55 |
Sent To |
E |
|
| Notes |
| 2006-08-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-14 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-14 |
Time |
09:46 |
Sent To |
M |
|
| Notes |
| 2006-04-14 00:00:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
15:47 |
Sent To |
Z |
|
| Notes |
| 2006-04-10 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-02-21 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-14 |
Time |
12:14 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-04-14 |
Time |
12:14 |
Sent To |
B |
|
| Notes |
| 2006-04-14 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND | | | MECHANICAL PERMIT # 06020859 HAS BEEN | | | VOIDED BY CUSTOMER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-28 |
Time |
08:27 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-02-28 |
Time |
08:27 |
Sent To |
P |
|
| Notes |
| 2006-02-28 00:00:00 | MECHANICAL PERMIT APPLIED FOR BUT NO | | | MECHANICAL PLANS SUBMITTED. PLEASE | | | SUBMIT MECHANICAL PLANS FOR REVIEW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-01 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-01 |
Time |
07:50 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-13 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-13 |
Time |
14:57 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-23 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-23 |
Time |
13:17 |
Sent To |
E |
|
| Notes |
| 2006-02-23 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO COPY OF | | | SITEPLAN/SURVEY WITH SETBACK OF THE | | | PROPOSED STRUCTURE. | | | 2. NO SITEPLAN/SURVEY PROVIDED FOR | | | REVIEW | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|