| Plan Review Stops For Permit 06020706 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-06-20 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-06-20 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | NEW PAGE 2.1 IS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-04-24 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-04-24 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-06 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-06 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | DENIED | | | | | | 1) SPECIFY THE LOCATION OF FIRE OR | | | FIRE/SMOKE RATED WALLS. SEE FBC 706. | | | | | | 2) ONE HOUR FIRE TENANT SEPARATION IS | | | REQUIRED FROM ADJACENT TENANTS. SPECIFY | | | LOCATIONS WITH DASHED OR DOTTED LINES | | | FOR CLARITY. SEE FBC 708. | | | | | | 3) SPECIFY THE REQUIRED CLASS OF WALL | | | AND CEILING FINISHES PER FBC 803. | | | | | | 4) THE SINK AND CABINETS ARE REQUIRED TO | | | COMPLY WITH ACCESSIBILITY REQUIREMENTS. | | | SEE FBC 11-4.24 AND 11-4.32.4. PROVIDE | | | ELEVATIONS. | | | | | | 5)11-4.1.6(2) DUTY TO PROVIDE | | | AN ACCESSIBLE PATH OF TRAVEL TO ALTERED | | | AREAS SHALL BE DEEMED DISPROPORTIONATE | | | TO THE OVERALL ALTERATION WHEN THE COST | | | EXCEEDS 20 % OF THE COST OF THE ALTERA- | | | TION TO THE PRIMARY FUNCTION AREA. | | | (A)(I) AN ACCESSIBLE ENTRANCE | | | (II) AN ACCESSIBLE ROUTE | | | (III) AT LEAST ONE ACCESSIBLE REST- | | | ROOM FOR EACH SEX OR A SINGLE | | | UNISEX RESTROOM | | | (IIII) ACCESSIBLE TELEPHONE | | | (IV) ELEMENTS SUCH AS PARKING, STOR- | | | AGE OR ALARMS. | | | SUBMIT A COST BREAKDOWN SHOWING THE 20% | | | OF ALTERATION COST TO BE SPENT ON | | | ACCESSIBILITY. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-06-22 |
Time |
07:42 |
Rev Time |
1.15 |
| Received By |
jleahy |
Date |
2006-06-22 |
Time |
07:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-04-21 |
Time |
08:29 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-04-21 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2006-04-21 00:00:00 | NO SIGNATURE FOR PLANS. | | | | | | LIGHTING TO BE INSTALLED PER CHAPTER 13 | | | OF THE 2004 FBC. | | | | | | JAKE | | | | | | 644-7291 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-23 |
Time |
20:57 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2006-02-23 |
Time |
20:57 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | NEED TO SHOW BRANCH CIRCUIT NUMBERS FOR | | | THE OUTLETS AND LIGHTS (NEW) | | | | | | PANEL SCHEDULE DOES NOT REFLECT LOADS | | | SHOWN ON DRAWINGS. LIGHTS AND OUTLETS. | | | | | | NO LOW VOLTAGE SYSTEMS SHOWN NEW | | | TELEPHONE COMPUTERS, ECT. ECT. | | | NO ROUGH INSPECTION WITHOUT PLANS FOR | | | LOW VOLTAGE. | | | | | | THERE IS NO SIGNATURE OF THE RESONSIBLE | | | PARTY FOR THESE DRAWINGS. | | | | | | NEED TO SHOW THE LOCATION OF THE PANEL | | | AND METER AND SERVICE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-22 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-22 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-25 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-25 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER/FIRE ALARM | | | REMODEL IF APPLICABLE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-02-17 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-02-17 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2006-02-17 00:00:00 | ******PASSED****** | | | | | | 1) GENERALLY, IT WOULD APPEAR THAT THE | | | MOST ACURATE OCCUPANCY CLASSIFICATION | | | FOR THIS SPACE IS BUSINESS. THE | | | CONFERENCE ROOM IS INCIDENTAL. OCCUPANT | | | LOAD WAS CALCULATED AS BUSINESS. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHER IS | | | REQUIRED. ACCESS TO AN EXTINGUISHER | | | SHALL NOT EXCEED 75' TRAVEL DISTANCE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-12 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
10:26 |
Sent To |
M |
|
| Notes |
| 2006-09-12 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-25 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-25 |
Time |
10:31 |
Sent To |
M |
|
| Notes |
| 2006-08-25 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-12 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-12 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | TO "BOB"#2 | | 2006-06-12 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-17 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-17 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | TO "BOB"#16 | | 2006-04-17 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-06 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-17 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2006-02-17 00:00:00 | TO "BOB"#10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-12 |
Time |
16:31 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-09-12 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2006-09-12 00:00:00 | RVVISION TO MECH. PLANS PAGE 3-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-01 |
Time |
15:33 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-09-01 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) PLEASE SHOW CFM'S AT SUPPLY AIR | | | GRILLS, WITHOUT THAT INFOMATION WE CAN | | | NOT TELL IF THE RETURN AIR DUCTS ARE THE | | | RIGHT SIZE. AND PLEASE CORRECT RETURN | | | AIR DUCT SIZES IF NEEDED. | | | | | | 2) PLEASE SHOW HOW THE RETURN AIR IS | | | GETTING BACK TO THE AIR HANDLER (DUCT | | | SIZE). | | | | | | 3) PLEASE SEE HIGH LIGHTS ON MECHANICAL | | | PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-20 |
Time |
15:38 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-06-20 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | MECH. PLANS PASSED ON 4-19-06. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-19 |
Time |
16:01 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-04-19 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | *** PROVISO *** | | | 1) REVISED MECHANICAL PLANS TO BE | | | SUBMITTED SHOWING HOW BALANCED RETURN | | | AIR WAS INSTALLED BEFORE ROUGH | | | MECHANICAL INSPECTION. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-17 |
Time |
11:53 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-02-17 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2006-02-17 00:00:00 | *** DENIED *** | | | 1) EACH OFFICE WITH A DOOR WILL REQUIRE | | | BALANCED RETURN AIR, PER 2004 FBC/M | | | 601.4 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-19 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-19 |
Time |
13:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-25 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-25 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | DENIED; | | | BREAK SINK IS REQUIRED TO HAVE A FRONTAL | | | APPROACH. FBC-2004 CHAPTER 11 SEC. | | | 11-4.24.3. KNEE CLEARANCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINK. SHOW | | | DETAIL OF CABINETS WITH DOORS, AND BASS | | | OF CABINET REMOVED. CHANGE THE CLEAR | | | FLOOR SPACE FROM SIDE APPROACH TO | | | FRONTAL APPROACH ON PAGE 2.1 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-01 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-01 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | DENIED; | | | 1.PAGE 2.1 SOUTH EAST SIDE NOTE | | | "EXISTING PLUMBING" NOT SHOWN ON DEMO. | | | SHEET. PLEASE SHOW WERE PLUMBING TIES | | | INTO BOTH SANITARY AND WATER. | | | 2.BREAK SINK TO COMPLY WITH FBC-2004 | | | CHAPTER 11 SEWC.11-4.24.1 THRU 11-4.24.7 | | | SHOW DETAIL ON PLANS. SHOW ALL | | | MEASUREMENTS REQUIRED AND NOTES FOR RAPS | | | AND FAUCET HANDLES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|