| Plan Review Stops For Permit 06020655 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-03-06 |
Time |
07:55 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-03-06 |
Time |
07:55 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-04-06 |
Time |
10:19 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2006-04-06 |
Time |
10:19 |
Sent To |
P |
|
| Notes |
| 2006-04-06 00:00:00 | PUT IN PLAN REVIEW FOR P PETTYJL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-23 |
Time |
13:07 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-02-23 |
Time |
12:54 |
Sent To |
P |
|
| Notes |
| 2006-02-23 00:00:00 | | | | FAILED | | | | | | THE APPLICATION INDICATES A POOL HEATER | | | IS GOING TO BE INSTALLED, BUT THE PLAN | | | INDICATES NO HEATER, PLEASE CORRELATE. | | | | | | IF A HEATER IS TO BE INSTALLED SUBMIT A | | | LOAD CALC WITH ALL LOADS. INDICATE | | | SERVICE SIZE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-02-24 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-02-24 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2006-04-24 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2006-04-24 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2006-04-24 00:00:00 | BUSINESS CARD ATTACHED FROM JOHN P ROACH | | | (PLANNING & ZONING) STATING "OK TO | | | BYPASS HISTORIC HOLD PER FRIEDERIKE | | | MITTNER CITY HISTORIC PRESERVATION | | | PLANNER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-04 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-04 |
Time |
08:40 |
Sent To |
E |
|
| Notes |
| 2006-04-04 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-17 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-17 |
Time |
14:20 |
Sent To |
Z |
|
| Notes |
| 2006-03-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-23 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-23 |
Time |
11:40 |
Sent To |
E |
|
| Notes |
| 2006-02-23 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-03-06 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-02-16 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-06 |
Time |
11:29 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-04-06 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-02-24 |
Time |
14:03 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-02-24 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2006-02-24 00:00:00 | DENIED | | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING | | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | | | 1) PERMIT APPLICATION INDICATES HEATER, | | | BUT THERE IS NONE INDICATED ON THE | | | PRINT.PLEASE CORRELATE. IF A POOL HEATER | | | IS INSTALLED PLEASE PROVIDE THE | | | FOLLOWING INFORMATION ON RESUBMITTAL. | | | 2) FBC-2004 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY.(REQUIRE | | | MANUFACTURE CUT SHEETS SUBMITTAL) | | | 3) FBC-2004 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF.( REQUIRE MANUFACTURE CUT SHEETS | | | SUBMITTAL) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX(561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-03-31 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-03-31 |
Time |
08:54 |
Sent To |
I |
|
| Notes |
| 2006-03-31 00:00:00 | NOTE: POOL EQUIP. CAN ONLY ENCROACH 4FT | | | INTO A SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-22 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-22 |
Time |
15:37 |
Sent To |
I |
|
| Notes |
| 2006-02-22 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE SETBACK OF THE | | | PROPOSED POOL (SIDE & REAR) ON TWO COPY | | | OF CURRENT SURVEYS | | | 2. SURVEYS PROVIDED DOES NOT SHOW THE | | | SETBACKS. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|