| Plan Review Stops For Permit 06020651 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2006-08-17 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2006-08-17 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | REVISIONS DATED 7/10/06 AND 8/2/06 OK | | | HHP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-20 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-20 |
Time |
17:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-05 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-05 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2006-05-05 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)DECLARE OCCUPANT LOAD FBC1004. | | | | | | 3.)DECLARE CONSTRUCTION TYPE FOR | | | CURRENT CODE, FBC6.DECLARE MINIMUM | | | REQUIRED FOR BUILDING HEIGHT AND AREA. | | | | | | 4.)DECLARE NUMBER OF STORIES.YOU | | | HAVE DECLARED A TYPE IV, SBC, BUT SOFFIT | | | DETAIL SHOWS COMBUSTIBLE FRAMING. | | | | | | 5.)THE SALES COUNTER IS TO COMPLY WITH | | | FBC11-7.1.2(1), SHOW DIMENSIONS. | | | | | | 6.)PROVIDE DIMENSION FOR TURNING | | | RADIUS D8, ENLARGED BATHROOM DETAIL. | | | ALSO PROVIDE WALL DIMENSIONS, NOT SHOWN | | | ON THE FLOOR PLAN OR THE ENLARGED | | | DETAIL. | | | | | | 7.)THE VALUE APPEARS LOW.PROVIDE A | | | BREAKDOWN OF COSTS, OR PROVIDE A MORE | | | REALISTIC VALUE, OR AN ESTIMATE USING | | | MARSHALL & SWIFT WILL BE DONE FOR YOU. | | | | | | 8.)SEE FBC11-4.1.6(2).SHOW | | | ACCESSIBLE ENTRANCE, ACCESSIBLE ROUTE, | | | PARKING.THE ACCESSIBLE RESTROOM | | | APPEARS TO BE EXISTING, IS THIS CORRECT? | | | | | | 9.)DECLARE GOVERNING CODE. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-24 |
Time |
13:40 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-08-24 |
Time |
13:31 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-17 |
Time |
13:34 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-08-17 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
| 2006-08-17 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THERE ARE NOW LOADS ON PANEL "B", | | | PLEASE SUBMIT SCHEDULE AND CALCULATION | | | FOR SAME. | | | | | | 2} THERE IS A SYMBOL TO THE RIGHT OF | | | CKTS A14,16 & A18,20 THAT DOES NOT | | | APPEAR ON THE LEGEND, BUT CONTAINS A 30 | | | AMP 3 WIRE,50 AMP 3 WIRE, 30 AMP 4 WIRE | | | AND 50 AMP 4 WIRE CIRCUITS. PLEASE | | | IDENTIFY PANEL AND CIRCUIT NUMBERS FOR | | | THOSE CIRCUITS, THERE ARE NO 3 POLE 30 | | | AMP CIRCUITS IN THE PANELS SCHEDULES. | | | | | | 3} CIRCUITS A4,16 AND A18,20 ARE | | | SPECIFIED AT 220 VOLTS, THE SYSTEM IS | | | 120/208, WHAT IS THE SOURCE FOR 220 VOLT | | | RECEPTACLES? | | | | | | 4} CIRCUITS A 27,29,30,31,32,33 ARE | | | SHOWN AS NO LOAD SPARES IN PANEL"A", BUT | | | NOW SHOW AS RECEPTACLES ON THE PLAN. | | | THEY ARE ALSO SHOWN AS EXISTING, BUT | | | DID NOT APPEAR ON THE OIGINAL PLANS. | | | PLEASE CLARIFY NEW OR EXISTING, ADD TO | | | PANEL SCHEDULE, AND RECALCULATE THE LOAD | | | PER 220. | | | | | | 5} PLEASE INDICATE THE ADDED TRACK | | | LIGHTING CIRCUIT(S) NUMBERS AND PANEL | | | DESIGNATION, CALCULATE PER 220.12(B). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-28 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-27 |
Time |
19:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-12 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-12 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE NO HAND DRAWN | | | CHNAGES ARE PERMITTED ON PLAN UNLESS | | | EACH AND EVERY CHANGE IS SIGNDED AND | | | DATED BY THE ENGINEER OF RECORD. | | | A PHOTO-COPY OF PLANS MAY BE DONE AND | | | THEN HAVE THE DESIGNER RE-SIGN, DATE AND | | | SEAL SHEETS. FS 481.221, 471.025 | | | | | | 2) NOTE: PLEASE SEE FBC CHAPTER 13, | | | 13-415.1.ABC.1.1,.1.2,.1.3. | | | PLEASE PROVIDE MIN CONTROLS REQUIRED, | | | SCHEDULING, LOCATIONS OF DEVICES AND | | | TIMED ON/OFF AND LOCATIONS AND TIME | | | LIMITS OF OVER RIDES DEVICES. | | | ** THIS WAS NOT IN FIRST REVIEW NOTES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-20 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-20 |
Time |
18:20 |
Sent To |
|
|
| Notes |
| 2006-03-20 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE REQUIRED TO | | | BE SIGNED, DATED AND SEALED BY THE | | | ENGINEER OF RECORD, (CHANE ENGINEERING) | | | FS 471.025 | | | | | | 2)NOTE: PLEASE COMPLETE CIRCUITING ON | | | PLANS FOR NEW LIGHTING AND CORRELATE | | | WITH THE SUBMITTED PANEL SCHEDULE. | | | PLEASE CIRCUIT NEW EXIT/EM LTS TO LOCAL | | | CIRCUIT. IT WAS NOTED THAT A NOTE IS | | | SHOWN ON PLANS TO CONNECT TO LOCAL AREA | | | LTS, HOWEVER THE CIRCUITS SHOULD BE | | | SHOWN FOR THESE.700.12E | | | | | | 3) NOTE: PLEASE CLARIFY IF THERE ARE NEW | | | OR EXISTING SHOW WINDOW RECEPTS.? | | | 210.62, 220.12 | | | THESE WILL BE REQUIRED IF NOT EXISITNG. | | | | | | ** PLEASE SEE IF THERE ARE ANY COMMENTS | | | FROM OTHER TRADES WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS ARE REQUIRED TO BE | | | SUBMITTED BACK FOR REFERENCE. THESE | | | SHEETS SHOULD BE SEPARATE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-17 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-17 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | REVISIONS DATED 7/10/06 AND 8/2/06. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-11 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-11 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2006-04-11 00:00:00 | ******APPROVED****** | | | | | | 1) SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEM REMODEL. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHERS TO | | | BE MOUNTED AT DISTANCES NOT TO EXCEED | | | 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2006-08-09 |
Time |
08:27 |
Sent To |
PC |
|
| Notes |
| 2006-08-09 00:00:00 | WAITING FOR "COMM" BD--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
17:42 |
Sent To |
E |
|
| Notes |
| 2006-06-25 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | TO "COMM" BD#9 | | 2006-05-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-05 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-15 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2006-03-16 00:00:00 | TO "COMM" BD#15 | | 2006-02-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-03-20 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-03-20 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2006-03-20 00:00:00 | NO MECHANICAL REQUIRED.3/20/06 HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-06 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-06 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2006-05-06 00:00:00 | ANY CHANGES TO BREAK ROOM SINK, SHALL | | | COMPLY WITH SEC. 11.4-24 |
|
|