Plan Review Details - Permit 06020587
Plan Review Stops For Permit 06020587
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-20 Cont ID  
Sent By amorse Date 2006-03-20 Time 09:43 Rev Time 0.33
Received By amorse Date 2006-03-20 Time 09:43 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-04-13 Cont ID  
Sent By btrobaug Date 2006-04-13 Time 18:29 Rev Time 0.33
Received By btrobaug Date 2006-04-13 Time 17:58 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-23 Cont ID  
Sent By btrobaug Date 2006-02-23 Time 07:10 Rev Time 0.50
Received By btrobaug Date 2006-02-23 Time 06:43 Sent To B
Notes
2006-02-23 00:00:00 
 FAILED
  
  
 PROVIDE A DISCONNECTING MEANS PER 600.6
 600.6 DISCONNECTS.
 EACH SIGN AND OUTLINE LIGHTING SYSTEM,
 OR FEEDER CIRCUIT OR BRANCH CIRCUIT
 SUPPLYING A SIGN OR OUTLINE LIGHTING
 SYSTEM, SHALL BE CONTROLLED BY AN
 EXTERNALLY OPERABLE SWITCH OR CIRCUIT
 BREAKER THAT WILL OPEN ALL UNGROUNDED
 CONDUCTORS. SIGNS AND OUTLINE LIGHTING
 SYSTEMS LOCATED WITHIN FOUNTAINS SHALL
 HAVE THE DISCONNECT LOCATED IN
 ACCORDANCE WITH 680.12.
 (1) WITHIN SIGHT OF THE SIGN. THE
 DISCONNECTING MEANS SHALL BE WITHIN
 SIGHT OF THE SIGN OR OUTLINE LIGHTING
 SYSTEM THAT IT CONTROLS. WHERE THE
 DISCONNECTING MEANS IS OUT OF THE LINE
 OF SIGHT FROM ANY SECTION THAT MAY BE
 ENERGIZED, THE DISCONNECTING MEANS SHALL
 BE CAPABLE OF BEING LOCKED IN THE OPEN
 POSITION.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-05 Cont ID  
Sent By adarroug Date 2006-04-05 Time 13:37 Rev Time 0.00
Received By adarroug Date 2006-04-05 Time 13:37 Sent To E
Notes
2006-04-05 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-22 Cont ID  
Sent By adarroug Date 2006-02-22 Time 11:07 Rev Time 0.00
Received By adarroug Date 2006-02-22 Time 11:07 Sent To E
Notes
2006-02-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-20 Cont ID  
Sent By amorse Date 2006-03-20 Time 09:43 Rev Time 0.00
Received By amorse Date 2006-02-15 Time 11:56 Sent To  
Notes
2006-02-15 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2006-02-21 Cont ID  
Sent By mmclean Date 2006-02-21 Time 14:38 Rev Time 0.00
Received By mmclean Date 2006-02-21 Time 14:37 Sent To I
Notes
***NONE***