Plan Review Details - Permit 06020497
Plan Review Stops For Permit 06020497
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-09-05 Cont ID  
Sent By alange Date 2006-09-05 Time 13:44 Rev Time 0.50
Received By alange Date 2006-09-05 Time 13:44 Sent To  
Notes
2006-09-05 00:00:00INSULATION REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-11 Cont ID  
Sent By alange Date 2006-05-11 Time 11:46 Rev Time 0.66
Received By alange Date 2006-05-11 Time 11:46 Sent To  
Notes
2006-05-11 00:00:00TRUSS DRAWINGS REC'D AND APPROVED.
 PORCH FOOTING CHANGE APPROVED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-04-04 Cont ID  
Sent By alange Date 2006-04-04 Time 14:48 Rev Time 1.65
Received By alange Date 2006-04-04 Time 14:38 Sent To  
Notes
2006-04-04 00:00:00PROVISIO
  
 SUBMIT TRUSS DRAWINGS FOR APPROVAL PRIOR
 TO INSTALLATION OF TRUSSES.
 SUBMIT ALL DRAWINGS WITH ORIGONAL SIGNED
 AND SEAL.SEAL SHOULD SHOW "LICENSED"
 NOT "CERTIFICATE".
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-01 Cont ID  
Sent By alange Date 2006-03-01 Time 13:37 Rev Time 2.00
Received By alange Date 2006-03-01 Time 13:25 Sent To  
Notes
2006-03-01 00:00:00DENIED
  
 1.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.CHECK ALL CODE
 REFERENCES AND VERIFY CORRECT CODE
 SECTIONS ARE USED.
  
 2.PLANS REQUIRED TO BE SIGNED, DATED
 AND SEALED BY THE ARCHITECT, PLEASE SEE
 FS 481.221 AND FAC 61G1-16.ONLY ON SET
 IS SEALED.
  
 3.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMMENDMENT TO FBC 106.3.3
  
 4.PLANS SPEC. PGT SH 4000 YET PRODUCT
 APPROVALS FOR SH-701 IS SUBMITTED.
  
 5.SUBMIT PRODUCT APPROVALS FOR BAHAMA
 SHUTTERS, STRAPS AND TIE-DOWNS.
  
 6.ALL PRODUCT APPROVALS SHALL HAVE THE
 FOLLOWING STATE PRODUCT APPROVALS
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7.SUBMIT TWO SETS OF TRUSS DRAWINGS
 COMPLYING WITH FBC 2004 R-802.10.1
  
 8.ENERGY CALCS TO NOT MATCH THE "R"
 VALUES ON PLANS.HAVE PREPARER AND
 OWNER/AGENT SIGN ENERGY CALCS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-15 Cont ID  
Sent By btrobaug Date 2006-09-15 Time 17:18 Rev Time 0.50
Received By btrobaug Date 2006-09-15 Time 16:50 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-03-23 Cont ID  
Sent By btrobaug Date 2006-03-23 Time 12:35 Rev Time 0.75
Received By btrobaug Date 2006-03-23 Time 12:07 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By btrobaug Date 2006-02-21 Time 13:00 Rev Time 0.50
Received By btrobaug Date 2006-02-21 Time 11:43 Sent To M
Notes
2006-02-21 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE ARCHTTECT MUST SIGN AND SEAL BOTH
 SETS OF PLANS SUBMITTED FOR REVIEW. SEE
 481.221.
  
 2} THE GROUNDING ELECTRODE CONDUCTOR
 MUST COMPLY WITH 250.66. #4 FOR A 2/0
 COU CONDUCTOR. (200 AMPS.)
  
 3} INDICATE THE AIC RATING OF THE
 SERVICE EQUIPMENT PER 110.9.
  
 4} THE EQUIPMENT GROUNDING CONDUCTOR
 FROM THE NEW 200 AMP DISCONNECT TO THE
 NEW 200 AMP PANEL MUST BE A MINIMUM OF
 #6 CU TO COMPLY WITH 250.122.
  
 5} THE A/C DISCONNECTS SHOWN BEHIND THE
 UNITS DO NOT COMPLY WITH 110.26
 CLEARANCE REQUIREMENTS.
  
 6} SMOKE DETECTORS ARE REQUIRED ON THE
 FIRST FLOOR PER 313.1 FBC. SEE REVIEWED
 PLAN FOR LOCATION.
  
 7} A RECEPTACLE MUST BE ADDED PER 210.52
 IN THE MASTER BEDROOM, SOUTHWEST CORNER.
  
 8} THE WHIRLPOOL MUST HAVE A GFI
 RECEPTACLE OR BREAKER PROTECTION, SPA OR
 HOT TUB SUPPLY RECEPTACLE. RECEPTACLES
 THAT PROVIDE POWER FOR A SPA OR HOT TUB
 SHALL BE GROUND-FAULT
 CIRCUIT-INTERRUPTER PROTECTED. 680.43(3)
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-09-15 Cont ID  
Sent By adarroug Date 2006-09-15 Time 13:16 Rev Time 0.00
Received By adarroug Date 2006-09-15 Time 13:16 Sent To E
Notes
2006-09-15 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-08-25 Cont ID  
Sent By adarroug Date 2006-08-25 Time 10:37 Rev Time 0.00
Received By adarroug Date 2006-08-25 Time 10:37 Sent To B
Notes
2006-08-25 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-06 Cont ID  
Sent By adarroug Date 2006-05-06 Time 16:22 Rev Time 0.00
Received By adarroug Date 2006-05-06 Time 16:22 Sent To B
Notes
2006-05-06 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-06 Cont ID  
Sent By adarroug Date 2006-05-06 Time 16:19 Rev Time 0.00
Received By adarroug Date 2006-05-06 Time 16:19 Sent To B
Notes
2006-05-06 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 12:05 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 12:05 Sent To E
Notes
2006-03-23 00:00:00TO BT'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-19 Cont ID  
Sent By adarroug Date 2006-02-19 Time 10:38 Rev Time 0.00
Received By adarroug Date 2006-02-19 Time 10:38 Sent To E
Notes
2006-02-19 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-01 Cont ID  
Sent By alange Date 2006-03-01 Time 13:37 Rev Time 0.00
Received By alange Date 2006-02-14 Time 14:52 Sent To  
Notes
2006-02-14 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2006-02-22 Cont ID  
Sent By tgordon Date 2006-02-22 Time 11:08 Rev Time 0.15
Received By tgordon Date 2006-02-22 Time 11:08 Sent To  
Notes
2006-02-22 00:00:00MECH. PERMIT #06020504 IS VOIDED, CUST.
 WILL APPLY FOR A MECH. PERMIT AT A LATER
 DATE. AND SUBMIT MECHANICAL PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By tgordon Date 2006-02-21 Time 14:24 Rev Time 0.30
Received By tgordon Date 2006-02-21 Time 14:24 Sent To P
Notes
2006-02-21 00:00:00*** DENIED ***
  
 1) MANUAL 'J' CALCULATIONS ARE MISSING
 FROM THE ENERGY CALCULATIONS, PLEASE
 SUPPLY MANUL 'J' CALCULATIONS.
  
 2) ENERGY CAL'S. NEED SIGNATURE OF
 PERSON PREPARED BY.
  
 3) ENERGY CAL'S. ARE CALLING FOR A 13
 SEER A/C SYSTEM, AND PLANS ARE CALLING
 FOR A 12 SEER SYSTEM THE TWO MUST
 COINCIDE, PLEASE CORRECT.
  
 4) MECHANICAL PLANS MUST SHOW ALL DUCT
 SIZES, GRILL SIZES, AND CFM'S. .
  
 5) RETURN AIR TRANSFER DUCTS MUST BE
 SIZED, SEE NOTE #6.
  
 6)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 7) SHOW ALL DUCT, AND GRILL SIZES TO NEW
 DUCT WORK FOR FIRST FLOOR.
  
 8) CLOTHES DRYER VENT MUST TERMINATE AT
 LEAST 4 FT. AWAY FROM A/C CONDENSER
 UNITS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-02-28 Cont ID  
Sent By jleech Date 2006-02-28 Time 14:14 Rev Time 0.00
Received By jleech Date 2006-02-28 Time 14:14 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-02-17 Cont ID  
Sent By mmclean Date 2006-02-17 Time 18:19 Rev Time 0.00
Received By mmclean Date 2006-02-17 Time 18:19 Sent To I
Notes
2006-02-17 00:00:00NOTE THE PROPOSED STRUCTURE IS 7FT FROM
 ACCESSORY STRUCTURE.