Plan Review Details - Permit 06020487
Plan Review Stops For Permit 06020487
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-02-28 Cont ID  
Sent By lursu Date 2006-02-28 Time 11:33 Rev Time 0.00
Received By lursu Date 2006-02-28 Time 11:31 Sent To  
Notes
2006-02-28 00:00:00USE THE EXISTING EXT # 0001 FOR THE UNIT
 304.LU
2006-02-10 00:00:00A COPY OF APPLICATION SENT TO ADDRESSING

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-03-08 Cont ID  
Sent By rmcdouga Date 2006-03-08 Time 07:40 Rev Time 0.00
Received By rmcdouga Date 2006-03-08 Time 07:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-28 Cont ID  
Sent By rmcdouga Date 2006-02-28 Time 13:23 Rev Time 0.00
Received By rmcdouga Date 2006-02-28 Time 13:23 Sent To  
Notes
2006-03-01 00:00:00DENIED
  
 1) 110.1.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OF THE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 PLEASE INDICATE THIS INFORMATION ON THE
 PLANS.
  
 2) THE ADDRESS AND PROPERTY CONTROL
 NUMBER ON THE PERMIT APPLICATION AND THE
 NOTICE OF COMENCEMENT DO NOT MATCH. THEY
 ARE FOR DIFFERENT BUILDINGS AND PARCELS.
 PLEASE CORRECT. IF APPLICATION IS
 CORRECT RECORD NEW NOC WITH CORRECTIONS.
  
 3) INDICATE THE FIRE RATED TENANT
 SEPARTION AND CORRIDOR WALLS ON THE
 PLAN.
  
 4) SPECIFY THE FLAME SPREAD AND SMOKE
 DEVELOPED CLASS OF THE INTERIOR WALL AND
 CEILING FINISHES THAT WILL BE INSTALLED.
 SEE 2004 FBC 803.
  
 5)11-4.1.6(2) DUTY TO PROVIDE AN
 ACCESSIBLE PATH OF TRAVEL TO ALTERED
 AREAS SHALL BE DEEMED DISPROPORTIONATE
 TO THE OVERALL ALTERATION WHEN THE COST
 EXCEEDS 20 % OF THE COST OF THE ALTERA-
 TION TO THE PRIMARY FUNCTION AREA.
 (A)(I) AN ACCESSIBLE ENTRANCE
 (II) AN ACCESSIBLE ROUTE
 (III) AT LEAST ONE ACCESSIBLE REST-
 ROOM FOR EACH SEX OR A SINGLE
 UNISEX RESTROOM
 (IIII) ACCESSIBLE TELEPHONE
 (IV) ELEMENTS SUCH AS PARKING, STOR-
 AGE OR ALARMS.
 -FBC 11-4.13.6 EXISTING DOOR AT COPY
 ROOM IS REQUIRED TO HAVE MANEUVERING
 CLEARANCE OF A MINIMUM OF 18" OF WALL
 SPACE AT THE LATCH ON THE PULL SIDE OF
 DOOR.
  
 - FBC 11-4.22.2 EXISTING BATHROOM DOOR
 SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACE REQUIRED FOR ANY FIXTURE.
  
 SUBMIT ITEMIZED COST BREAKDOWN LISTING
 THE ITEMS AND COSTS SHOWING THAT 20% OF
 $1200 OR $2400 HAS BEEN ALLOCATED TO
 MEETING ACCESSIBILITY REQUIREMENTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-23 Cont ID  
Sent By jleahy Date 2006-02-23 Time 21:12 Rev Time 0.30
Received By jleahy Date 2006-02-23 Time 21:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-02-10 Cont ID  
Sent By jleahy Date 2006-02-10 Time 20:21 Rev Time 0.45
Received By jleahy Date 2006-02-10 Time 20:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-02-15 Cont ID  
Sent By mwennerg Date 2006-02-15 Time 09:48 Rev Time 0.00
Received By mwennerg Date 2006-02-15 Time 09:48 Sent To  
Notes
2006-02-15 00:00:00******PROVISO******
  
 1) EXIT SIGNS/EMERGENCY LIGHTING
 REQUIRED AS NEEDED.
  
 2) SEPARATE SHOP DRAWING/PERMIT REQUIRED
 FOR FIRE SPRINKLER REMODEL IF APPLICABE.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLANS REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-28 Cont ID  
Sent By rmcdouga Date 2006-02-28 Time 13:23 Rev Time 0.00
Received By rmcdouga Date 2006-02-10 Time 14:25 Sent To  
Notes
2006-02-10 00:00:00TO "BOB"#3

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-02-27 Cont ID  
Sent By tgordon Date 2006-02-13 Time 15:34 Rev Time 0.25
Received By tgordon Date 2006-02-27 Time 08:30 Sent To  
Notes
2006-02-13 00:00:00 

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-02-15 Cont ID  
Sent By jleech Date 2006-02-15 Time 14:41 Rev Time 0.00
Received By jleech Date 2006-02-15 Time 14:41 Sent To  
Notes
2006-02-15 00:00:00NO PLUMBING WORK ON THIS PLAN.