Plan Review Details - Permit 06020481
| Plan Review Stops For Permit 06020481 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2021-06-30 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2021-06-30 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2021-06-30 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-03 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2006-05-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)THE ANCHORING YOU HAVE SPECIFIED IS | | | NOT COMPLIANT FOR THE WIND PRESSURE | | | SPECIFIED BY THE ENGINEER. | | | | | | 2.)HAVE THE ENGINEER STATE WHETHER | | | THESE OPENINGS ARE IN ZONE 4 OR ZONE 5. | | | NONE WAS DECLARED IN THE LETTER, AND THE | | | DESIGN PRESSURES APPEAR TO BE ZONE 4 | | | DESIGN PRESSURES.THIS APPEARS TO BE A | | | CORNER UNIT.(COMMENT ADDED 5/31 AFTER | | | CONVERSATION WITH CONTRACTOR) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-01 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-01 |
Time |
17:40 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED | | | ITEMS APPLY | | | | | | _XX_1.A NOTICE OF COMMENCEMENT MUST | | | BE FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED, FS713.13. | | | | | | _XX_2.PROVIDE BUILDING HEIGHT. | | | DESIGN PRESSURES FOR BUILDINGS OVER | | | 60FEET ARE REQUIRED TO BE DESIGNED USING | | | ASCE7, FBC1609.1.1. DOCUMENTS PREPARED | | | BY AN ENGINEER AND SUBMITTED FOR PUBLIC | | | RECORD ARE TO BE SIGNED SEALED ORIGINALS | | | FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO | | | ASSOCIATION APPROVAL. | | | | | | _XX_4.COMPLETE THE ATTACHED | | | INSTALLATION SCHEDULE OR PROVIDE | | | REQUIRED INFORMATION IN A SIMILAR | | | FORMAT. | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED, FAC9B72, | | | WWW.FLORIDABUILDING.ORG. | | | | | | ____6.ON THE PRODUCT APPROVAL, MARK | | | WHICH DETAILS APPLY TO THIS JOB. | | | | | | ____7.SHOW THE EMERGENCY MEANS OF | | | ESCAPE, FBC R310 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
08:51 |
Sent To |
B |
|
| Notes |
| 2006-04-27 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-01 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-02-13 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | TO "MISC" BOX#1 |
|
|
|