Plan Review Details - Permit 06020466
| Plan Review Stops For Permit 06020466 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-04-26 |
Time |
15:36 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-04-26 |
Time |
15:36 |
Sent To |
PC |
|
| Notes |
| 2006-04-26 00:00:00 | REVISION: REVISED DRAWING AS REQUESTED | | | BY INSPECTOR, SHOWING EXISTING PIPING | | | BACK TO METER. REFERENCE GEN/RES PERMIT | | | #06020464 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-28 |
Time |
11:16 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-03-28 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-06 |
Time |
14:13 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-03-06 |
Time |
14:12 |
Sent To |
B |
|
| Notes |
| 2006-03-06 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PERMIT: | | | | | | 1. GAS PERMIT CANNOT APPROVED WITH OUT | | | ZONING APPROVAL OF GENERATOR LOCATION. | | | 2. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS. | | | 3. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES. UNDERGROUND | | | GALVANIZED PIPE NOT APPROVED PER SEC. | | | 404.8, 404.8.2. | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | (NOTE: ON SUBMITTED DRAWING THERE ARE | | | TWO INDCATED DELIVERY PRESSURES ONE OF | | | 12" WC AND THE OTHER 2PSI. WHAT IS THE | | | DELIVERY PRESSURE YOU WANT TO USE?) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-02-25 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2006-02-25 00:00:00 | TO "GEN-RES" BOX W/GENERATOR PERMIT |
|
|
|