Plan Review Details - Permit 06020433
Plan Review Stops For Permit 06020433
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-13 Cont ID  
Sent By alange Date 2006-03-13 Time 10:58 Rev Time 0.33
Received By alange Date 2006-03-13 Time 10:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-24 Time 12:40 Rev Time 0.50
Received By btrobaug Date 2006-03-24 Time 12:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-03-01 Cont ID  
Sent By btrobaug Date 2006-03-01 Time 12:19 Rev Time 0.50
Received By btrobaug Date 2006-03-01 Time 11:42 Sent To M
Notes
2006-03-01 00:00:00 
 PROVIDE A LOAD CALCULATION PER 702.5
 CAPACITY AND RATING.
 AN OPTIONAL STANDBY SYSTEM SHALL HAVE
 ADEQUATE CAPACITY AND RATING FOR THE
 SUPPLY OF ALL EQUIPMENT INTENDED TO BE
 OPERATED AT ONE TIME.
 INDICATING THE SUPPLY EXCEEDS THE
 INTENDED LOAD.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-03-06 Cont ID  
Sent By mperson Date 2006-03-06 Time 13:41 Rev Time 0.15
Received By mperson Date 2006-03-06 Time 13:41 Sent To B
Notes
2006-03-06 00:00:00NOTE: GAS PERMIT REQUIRED. GAS
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT
 APPLICATION.ALL GAS INSPECTIONS TO BE
 COMPLETE BEFORE FINAL RES-GEN INSPECTION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-17 Cont ID  
Sent By adarroug Date 2006-03-17 Time 16:17 Rev Time 0.00
Received By adarroug Date 2006-03-17 Time 16:17 Sent To E
Notes
2006-03-17 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-25 Cont ID  
Sent By adarroug Date 2006-02-25 Time 12:08 Rev Time 0.00
Received By adarroug Date 2006-02-25 Time 12:08 Sent To E
Notes
2006-02-25 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-13 Cont ID  
Sent By alange Date 2006-03-13 Time 10:58 Rev Time 0.00
Received By alange Date 2006-02-13 Time 17:21 Sent To  
Notes
2006-02-13 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-03-02 Cont ID  
Sent By tgordon Date 2006-03-02 Time 11:03 Rev Time 0.15
Received By tgordon Date 2006-03-02 Time 11:03 Sent To P
Notes
2006-03-02 00:00:00*** PROVISO ***
 1)GENERATOR EXHUST MUST BE TEN FEET AWAY
 FROM ANY BUILDING OPENINGS (WINDOWS,
 DOORS, ROOF & EAVE VENTS), AND TEN FEET
 AWAY FROM ADJECENT BUILDING OPENS. PER
 2004 FBC/M 401.5.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-03-06 Cont ID  
Sent By mperson Date 2006-03-06 Time 13:41 Rev Time 0.00
Received By mperson Date 2006-03-06 Time 13:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-02-24 Cont ID  
Sent By mmclean Date 2006-02-24 Time 11:10 Rev Time 0.00
Received By mmclean Date 2006-02-24 Time 11:10 Sent To I
Notes
***NONE***