| Plan Review Stops For Permit 06020393 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-04-07 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-04-07 |
Time |
13:49 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-03-02 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-03-02 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2006-03-02 00:00:00 | | | | | | | | | | BUILDING REVIEW COMMENTS | | | -------- ------ -------- | | | | | | | | | | | | 1) | | | EXPLAIN NEW INFORMATION FOR EXISTING | | | ROOF TO BE RE-SHEATHED AND NEW OPENINGS | | | INCLUDED WITH NO SUPPORTING DETAILS, | | | WILL THERE BE A ROOF COVER APPLIED AND | | | IF SO A SEPERATE ROOF PERMIT WILL BE | | | REQUIRED. | | | | | | 2) | | | WHERE IS SECTION 'C' ON SHEET S-1. | | | | | | 3) | | | CONCRETE PAD PLACEMENT SHALL BE GIVEN | | | SPECIFIC LOCATION NOT GENERAL. | | | | | | 4) | | | NATURAL AIR INTAKE CALCULATIONS MAYBE | | | REQUIRED NOW THAT THE PLAN CALLS FOR A | | | SOLID ROOF, IT WAS ORIGINALLY DESCRIBED | | | AS AN OPEN AIR STRUCTURE. | | | | | | 5) | | | PRODUCE 2 COMPLETE SETS OF CONSTUCTION | | | DRAWINGS FOR PERMIT ISSUE. | | | | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-02-17 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-02-17 |
Time |
18:20 |
Sent To |
P |
|
| Notes |
| 2006-02-17 00:00:00 | | | | | | | | | | BUILDING COMMENTS | | | -------- -------- | | | | | | PROVISO | | | ------- | | | | | | | | | | | | HAVE ENGINEER CORRECT STRUCTURAL NOTES | | | ON SHEET S-2. | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-07 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-07 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2006-04-07 00:00:00 | COLUMN BEING REMOVED AS REDLINED ON | | | PLANS PER 110.26,110.34 | | | | | | SEE "S" SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-06 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-06 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
| 2006-03-06 00:00:00 | ***** NOTE/ FAIL***** | | | | | | 1)NOTE: ELECTRICAL PLANS REDLINED AS | | | COLUMN IS STILL SHOWN. SEE S-SHEETS AS | | | THIS COLUMN IS BEING REMOVED. | | | | | | 2)NOTE: PLEASE KNOW, PLANS TO REMAIN IN | | | "F" STATUS UNTIL MECHANICAL AND BLDG | | | REVIEWS ARE OK. | | | PLEASE SEE BLDG SHEETS NOW INDICATE A | | | ROOF OVER THE GENERATORS. | | | PLEASE SEE MECHANICAL REVIEW AS AIR | | | INTAKE CALCULATIONS FOR MAKE UP AIR | | | WOULD BE NEEDED. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE | | | CALL.\ | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-08 |
Time |
16:50 |
Sent To |
Z |
|
| Notes |
| 2006-02-08 00:00:00 | ********** UNSAT ************** | | | | | | 1)NOTE: PLEASE DISRIBE PROJECT AS BEING | | | INDICATED ON PLANS ON PERMIT | | | APPLICATION. IF 2 GENERATORS ETC. | | | | | | 2)NOTE: PLEASE SUBMIT MANUFACTURES | | | SPEC/CUT SHEETS FOR ALL NEW EQUIPMENT | | | BEING INSTALLED. GENERATOR, | | | SYNCHRONIZATION EQUIPMENT, FUEL TANKS, | | | ANY ATS EQUIPMENT ETC. | | | PLEASE BE SURE ALL LISTINGS AS INDICATE | | | FROM A NRTL. | | | | | | 3)NOTE: PLEASE SEE THE PROPOSED | | | GENERATORS ARE SUBSTANTIALLY LARGER THAN | | | THE PREVIOUS ORIGIANL GENERATORS. PLEASE | | | SEE PLANS SHOW THESE BEING LOCATED HALF | | | IN AND HALF OUT OF GEN BLDG?? | | | IF THESE GEN'S ARE GOING TO BE "OUTSIDE" | | | RAINTIGHT GEN'S, PLEASE BE SURE ALL MIN | | | CLEARENCE REQUIREMENTS FOR PROPER | | | VENTILATION IS PROVIDED. PLEASE SEE | | | FOLLOWING COMMENT. | | | | | | 4)NOTE: PLEASE SEE CLEARENCES FOR NEC | | | CODE COMPLIANCE IS NOT MET PER TABLES | | | 110.34A. | | | PLEASE ALSO SEE ENTRANCE, EGRESS | | | ACCESSED IS ALSO NOT MET PER 110.33A1 | | | ETC. | | | | | | 5)NOTE: PLEASE SEE NO INFORMATION IS | | | PROVIDED FOR OCP AT GEN'S TO FEED NEW | | | EQUIPMENT. | | | PLEASE SEE 445.13 FOR SIZING ETC IFNO | | | OCP IS PROVIDED AT GEN. ETC | | | | | | 6)NOTE: PLEASE PROVIDE MORE INFORMATION | | | ON TYOE OF CONDUCTORS ARE BEING | | | INSTALLED FOR 5KV CONDUCTORS. PLEASE SEE | | | TABLES 310.60 | | | PLEASE SEE THE # OF CONDUCTORS IN | | | CONDUITS, AND SIZE , OCP AND AMBIENT | | | TEMPS, AND VOLTAGE DROP MUST BE | | | CONSIDERED. UNABLE TO DO THIS AT THIS | | | TIME. | | | ** PLEASE COMPLETE. | | | | | | 7)NOTE: PLEASE CLARIFY IF THERE IS NEW | | | OR EXISTING TRANSFER EQUIPMENT. | | | PLEASE SEE THIS UNCLEAR ON ONE-LINE. | | | 215.5 | | | | | | 8)NOTE; PLEASE PROVIDE THE MIN LOADS FOR | | | THE EXISTING LOADS WHICH WILL BE LOADED | | | ON NEW GENERATORS. | | | IT IS KNOWN THAT THESE WILL BE FEEDING | | | EXISTING PUMPS ETC, HOWEVER THERE IS NO | | | RECORD OF THE IMPOSED LOADS. | | | PLEASE KNOW, THIS OFFICE HAD REVIEWED | | | DOCUMENTATION IN WHICH THE GEN'S WERE | | | GOING TO BE 3500KW. | | | PLEASE VERIFY AND SHOW LOADS. | | | 215.5 | | | | | | 9)NOTE:PLEASE PROVIDE THE LOCATIONS OF | | | OTHER EQUIPMENT. GEN SW GEAR BUS ETC. | | | | | | 10)NOTE: PLEASE SEE THE GC IS APPLYING | | | ONLY FOR THE INSTALLATION OF THE | | | GENERATOR. PLEASE KNOW, A PERMIT MUST BE | | | APPLIED FOR THE ELECTRICAL HOOK-UP AND | | | INSTALLATION. THIS WILL BE A GEN- ELEC | | | TYPE PERMIT. PLEASE ALSO KNOW A FUEL | | | PERMIT WILL BE REQUIRED FOR SCOPE OF | | | WORK FOR FUEL TANKS, PIPING ETC. | | | | | | ** PLEASE SEE POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | ** PLEASE BE SURE TO REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-04-05 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-04-05 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-03 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-03 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SUBMIT (2) COMPLETE SETS OF | | | PLANS FOR REVIEW. | | | | | | 2) DERM APPROVAL IS REQUIRED AND MUST BE | | | REFLECTED ON DRAWINGS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-02-15 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-14 |
Time |
10:28 |
Sent To |
I |
|
| Notes |
| 2006-02-15 00:00:00 | DENIED: | | | | | | 1) SHALL COMPLY WITH NFPA 110 STANDARD | | | FOR EMERGENCY AND STANDBY POWER SYSTEMS | | | 2002 EDITION. | | | | | | | | | 2) PLEASE SUBMIT MANUFACTURES SPEC'S AND | | | CUT SHEETS FOR ALL NEW EQUIPMENT BEING | | | INSTALLED. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-02-21 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-02-21 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | FUEL SOURCE FOR GENERATORS IS DIESEL | | | ONLY. NO NATURAL/LP GAS FOUND. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-03-02 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-03-01 |
Time |
17:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-15 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-15 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2006-02-15 00:00:00 | TO "LMARTINEZ" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-15 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-15 |
Time |
10:26 |
Sent To |
M |
|
| Notes |
| 2006-02-15 00:00:00 | TO "PKRAUSS" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-09 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-09 |
Time |
12:07 |
Sent To |
M |
|
| Notes |
| 2006-02-09 00:00:00 | TO "TGORDON" DESK--EXPIDITED PLAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-02-22 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-02-08 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | TO "MMCLEAN" DESK--EXPIDITED PLAN PER | | | "RBROWN" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-04-04 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-04-04 |
Time |
13:36 |
Sent To |
P |
|
| Notes |
| 2006-04-04 00:00:00 | PROVISO: | | | | | | 1.PER 2004 FMC 1302.3 PIPE MATERIAL | | | FOR FUEL OIL PIPING SHALL BE IN | | | ACCORDANCE WITH TABLE 1302.3, | | | NONMETALLIC PIPE - ASTM D2996. | | | THE SUBMITTAL FOR THE SPECIFICATION OF | | | THE FUEL OIL PIPING INDICATES ASTM | | | D2310.THIS SHOULD READ ASTM D2996 AS | | | THE STANDARD.ASTM D2310 IS A | | | CLASSIFICATION UNDER ASTM D2996 & | | | RTRP-11AF REFERENCES THE DESIGNATION | | | CODE.THE MARKING OF THE PIPE SHALL | | | COMPLY WITH ASTM D2996 SUB-SECTION 10. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-15 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-15 |
Time |
14:13 |
Sent To |
I |
|
| Notes |
| 2006-02-15 00:00:00 | DENIED: | | | PLEASE PROVIDE A MINIMUM OF 4 COPIES TO | | | THE DERM AT 3323 BELVEDERE ROAD BLDG | | | #502, ATTENTION TO CHIP GREEN.CHIP | | | GREEN MAY BE CONTACTED AT (561)233-2504. | | | | | | PLEASE RESUBMIT AFTER DERM APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2006-02-09 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2006-02-09 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2006-02-09 00:00:00 | GENERATOR IS WITHIN THE PROPERTY. NO DMP | | | REVIEW REQUIRED. | | | | | | PLANS RETURNED TO INCOMING FOR FURTHER | | | PROCESS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-09 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-08 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | PLANS ROUTED TO DPLANNER FOR ELECTRICAL | | | REVIEW PER RBROWN. |
|
|