| 2006-02-22 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 06020332 |
| | ADD: 213 CLEMATIS ST |
| | CONT: THOMAAS WILLIAMS CONSTRUCTION |
| | TEL: (954)802-0723 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) THE PERMIT APPLICATION AND WORK |
| | DESCRIBED ON PLANS DOES NOT MATCH, THIS |
| | REVIEW WILL BE COMPLETED WITH THE |
| | DESCRIPTION OF WORK DESCRIBED ON PLANS. |
| | |
| | 2) THE DESCRIPTION OF WORK DESCRIBED ON |
| | THE PLANS IS A LEVEL 2 OF THE EXISTING |
| | BUILDINGS 2004 FBC. SEC 304.1 LEVEL 2 |
| | ALTERATIONS INCLUDE THE RECONFIGURATION |
| | OF SPACE, THE ADDITION OR ELIMINATION OF |
| | ANY DOORS OR WINDOWS, THE |
| | RECONFIGURATION OR EXTENSION OF ANY |
| | SYSTEM, OR THE INSTALLATION OF ANY |
| | ADDITIONAL EQUIPMENT. ALTERATIONS |
| | LEVEL 2, CHAPTER 6 OF THE EXISTING |
| | BUILDING FBC SHALL APPLY. |
| | |
| | 3) PLEASE PROVIDE A CROSS SECTION BOTH |
| | NORTH / SOUTH AS WELL AS EAST / WEST OF |
| | THE SO CALLED MEZZANINE LEVEL FOR |
| | CLARIFICATION. PLEASE PROVIDE ELEVATIONS |
| | |
| | FLOOR TO CEILING MEASUREMENTS TO BE |
| | INCLUDED. |
| | |
| | 3A) MEZZANINE VS SECOND STORY SEE |
| | DEFINITION OF MEZZANINE MUST COMMUNICATE |
| | WITH THE ROOM IT IS IN. IT APPEARS THERE |
| | IS A WALL DIVIDING THE FRONT OF THE |
| | BUILDING WITH THE REAR PORTION MAKING IT |
| | |
| | A SECOND STORY AND NOT A MEZZANINE. |
| | SEESEE 2004 FBC SECTION 502 DEFINITIONS: |
| | |
| | MEZZANINE. AN INTERMEDIATE LEVEL OR |
| | LEVELS BETWEEN THE FLOOR AND CEILING OF |
| | ANY STORY WITH AN AGGREGATE FLOOR AREA |
| | OF NOT MORE THAN ONE-THIRD OF THE AREA |
| | OF THE ROOM OR SPACE IN WHICH THE LEVEL |
| | OR LEVELS ARE LOCATED (SEE SECTION 505 |
| | ). |
| | |
| | HEIGHT, STORY. THE VERTICAL DISTANCE |
| | FROM TOP TO TOP OF TWO SUCCESSIVE |
| | FINISHED FLOOR SURFACES; AND, FOR THE |
| | TOP MOST STORY, FROM THE TOP OF THE |
| | FLOOR FINISH TO THE TOP OF THE CEILING |
| | JOISTS OR, WHERE THERE IS NOT A CEILING, |
| | TO THE TOP OF THE ROOF RAFTERS. |
| | |
| | 1208.2 MINIMUM CEILING HEIGHTS. |
| | OCCUPIABLE SPACES, HABITABLE SPACES AND |
| | CORRIDORS SHALL HAVE A CEILING HEIGHT OF |
| | NOT LESS THAN 7 FEET 6 INCHES (2286 MM). |
| | BATHROOMS, TOILET ROOMS, KITCHENS, |
| | STORAGE ROOMS AND LAUNDRY ROOMS SHALL BE |
| | PERMITTED TO HAVE A CEILING HEIGHT OF |
| | NOT LESS THAN 7 FEET (2134 MM). |
| | |
| | 3B)2004 FBC EXISTING BUILDINGS 605.4 |
| | EGRESS DOORWAYS. |
| | EGRESS DOORWAYS IN ANY WORK AREA SHALL |
| | COMPLY WITH SECTIONS 605.4.1 THROUGH |
| | 605.4.5 . |
| | |
| | 3C) 2004 FBC EXISTING BUILDING 605.4.2 |
| | DOOR SWING. |
| | IN THE WORK AREA AND IN THE EGRESS PATH |
| | FROM ANY WORK AREA TO THE EXIT |
| | DISCHARGE, ALL EGRESS DOORS SERVING AN |
| | OCCUPANT LOAD GREATER THAN 50 SHALL |
| | SWING IN THE DIRECTION OF EXIT TRAVEL. |
| | |
| | |
| | 3D) 2004 EXISTING BUILDING FBC 603.2.3 |
| | SUPPLEMENTAL STAIRWAY ENCLOSURE |
| | REQUIREMENTS. |
| | WHERE THE WORK AREA ON ANY FLOOR EXCEEDS |
| | 50 PERCENT OF THAT FLOOR AREA, STAIRWAYS |
| | THAT ARE PART OF THE MEANS OF EGRESS |
| | SERVING THE WORK AREA SHALL, AT A |
| | MINIMUM, BE ENCLOSED WITH SMOKE-TIGHT |
| | CONSTRUCTION ON THE HIGHEST WORK AREA |
| | FLOOR AND ALL FLOORS BELOW. |
| | PROVIDE A SECTION THROUGH STAIRWAY |
| | INDICATING SHAFT CONSTRUCTIONAND THE |
| | LOCATION OF THE WOMENS HANDICAPPED |
| | RESTROOM DOORWAY . |
| | |
| | 3E) 2004 EXISTING BUILDING 603.4 |
| | INTERIOR FINISH. |
| | THE INTERIOR FINISH OF WALLS AND |
| | CEILINGS IN EXITS AND CORRIDORS IN ANY |
| | WORK AREA SHALL COMPLY WITH THE |
| | REQUIREMENTS OF THE FLORIDA BUILDING |
| | CODE, BUILDING . |
| | |
| | 3F) 2004 EXISTING BUILDING 607.4 |
| | EXISTING STRUCTURAL MEMBERS. |
| | EXISTING STRUCTURAL COMPONENTS |
| | SUPPORTING ADDITIONAL EQUIPMENT OR |
| | SUBJECTED TO ADDITIONAL LOADS BASED ON |
| | FLORIDA BUILDING CODE, BUILDING, TABLES |
| | 1607.1 AND 1607.6 AS A RESULT OF A |
| | RECONFIGURATION OF SPACES SHALL COMPLY |
| | WITH SECTIONS 607.4.1 THROUGH 607.4.3. |
| | |
| | 607.4.1 GRAVITY LOADS. |
| | EXISTING STRUCTURAL ELEMENTS SUPPORTING |
| | ANY ADDITIONAL GRAVITY LOADS AS A RESULT |
| | OF ADDITIONAL EQUIPMENT OR SPACE |
| | RECONFIGURATION SHALL COMPLY WITH THE |
| | FLORIDA BUILDING CODE, BUILDING . |
| | |
| | 3G) PLANS DO NOT IDENTIFY DOORWAYS WITH |
| | ALPHA OR NUMERIC CHARACTERS, FIRST FLOOR |
| | DOORWAY IT APPEARS TO BE A FREEZER DOOR. |
| | 2004 FBC 1008.1.8.8 |
| | DURING ITS SWING, ANY DOOR IN A MEANS OF |
| | EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST |
| | ONE HALF OF THE REQUIRED WIDTH OF AN |
| | AISLE, CORRIDOR, PASSAGEWAY, OR LANDING, |
| | NOR PROJECT MORE THAN 7 INCHES (178 MM) |
| | INTO THE REQUIRED WIDTH OF AN AISLE, |
| | CORRIDOR, PASSAGEWAY OR LANDING, WHEN |
| | FULLY OPEN. DOORS SHALL NOT OPEN |
| | IMMEDIATELY ONTO A STAIR WITHOUT A |
| | LANDING. THE LANDING SHALL HAVE A WIDTH |
| | AT LEAST EQUAL TO THE WIDTH OF THE DOOR. |
| | |
| | 3H) DOORWAY JUST RIGHT OF THE FIRST |
| | FLOOR FREEZER, ELEC SHEETS INDICATE ICE |
| | MACHINES; |
| | 11-4.13.6 MANEUVERING CLEARENCES |
| | AT DOORS. MINIMUM MANEUVERING CLEARENCES |
| | AT DOORS THAT ARE NOT AUTOMATIC OR |
| | POWER-ASSISTED SHALL BE AS SHOWN IN |
| | FIG. 25. THE FLOOR OR GROUND AREA WITH |
| | IN THE REQUIRED CLEARENCES SHALL BE |
| | CLEAR & LEVEL. |
| | |
| | 3I) BOTH EXISTING RESTROOM DOORS SCALE |
| | TO BE 2'-0" DOORS , 2004 EXISTING |
| | BUILDING CODE 605.4 EGRESS DOORWAYS IN |
| | ANY WORK AREA SHALL COMPLY WITH SECTIONS |
| | 605.4.1 THROUGH 605.4.5. |
| | 2004 FBC 1008.1.1 SIZE OF DOORS. |
| | THE MINIMUM WIDTH OF EACH DOOR OPENING |
| | SHALL BE SUFFICIENT FOR THE OCCUPANT |
| | LOAD THEREOF AND SHALL PROVIDE A CLEAR |
| | WIDTH OF NOT LESS THAN 32 INCHES (813 |
| | MM). CLEAR OPENINGS OF DOORWAYS WITH |
| | SWINGING DOORS SHALL BE MEASURED BETWEEN |
| | THE FACE OF THE DOOR AND THE STOP, WITH |
| | THE DOOR OPEN 90 DEGREES (1.57 RAD). |
| | 2004 FBC11-4.1.6(2) DUTY TO |
| | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO |
| | ALTERED AREAS SHALL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL |
| | ALTERATION WHEN THE COST EXCEEDS 20 % OF |
| | THE COST OF THE ALTERA- TION TO THE |
| | PRIMARY FUNCTION AREA.(A)(I) AN |
| | ACCESSIBLE ENTRANCE |
| | (II) AN ACCESSIBLE ROUTE |
| | (III) AT LEAST ONE ACCESSIBLE REST- |
| | ROOM FOR EACH SEX OR A SINGLE |
| | UNISEX RESTROOM |
| | (IIII) ACCESSIBLE TELEPHONE |
| | (IV) ELEMENTS SUCH AS PARKING, STOR- |
| | AGE OR ALARMS. |
| | |
| | 4) COVER SHEET NOTE ESIXTING |
| | CONSTRUCTION BUILDING TYPE ? |
| | UNKNOWN?NOTE 4C IS REQUIRED BEFORE A |
| | PERMIT WILL BE ISSUED. SOME EXPLORATION |
| | ON THE CONTRACTORS PART MAY BE |
| | NECCESSARY TO DETERMINE MINIMUM BUILDING |
| | TYPE. |
| | 110.2* W. P. B. ADMINISTRATIVE CODE, |
| | INFORMATION THAT IS REQUIRED FOR RECORD |
| | KEEPING & FOR CERTIFICATE OF OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH |
| | THE PERMIT WAS ISSUED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| | WITH THE PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED |
| | IN CHAPTER 6, TABLE 601. |
| | D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| | PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| | IS REQUIRED. |
| | F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| | OF THE BUILDING PERMIT. |
| | |
| | 5) PLANS, SPECIFICATIONS,REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN |
| | PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND |
| | SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| | TO THE DOCUMENT. |
| | FL STATE STAT: 61G15-23.002 ENGINEERS |
| | FL ATATE STAT: 61G16.003 ARCHITECTS |
| | |
| | 6) PROVIDE NOC RECORDED WITH THE CLERK |
| | OF COURT BEFORE A PERMIT CAN BE ISSUED. |
| | NOTE 713.13(2) IF WORK HAS NOT BEEN |
| | STARTED AFTER RECORDING OF NOC IT |
| | BECOMES VOID REQUIRING RE-RECORDING. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |