Plan Review Details - Permit 06020320
| Plan Review Stops For Permit 06020320 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-02-10 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-02-10 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2006-02-10 00:00:00 | CREATE EXTENSION #0002 FOR THE SUITE | | | 1006 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-02-13 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-13 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | DENIED | | | | | | 1)NEW DOOR MUST COMPLY WITH FAIR HOUSING | | | REQUIREMENTS. USEABLE DOORS MUST PROVIDE | | | A NOMINAL 32" CLEAR OPENING OF AT LEAST | | | 31-5/8 INCHES CLEAR. | | | | | | 2) SPECIFY THE MATERIAL THAT WILL BE | | | USED TO FRAME THE INTERIOR WALLS. | | | PARTITIONS MUST BE CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS. FBC 603 | | | | | | 3) A MECHANICAL PERMIT WIL BE REQUIRED | | | TO PROVIDE FOR RETURN AIR FROM THE | | | DEN/STUDY WHEN THE OPENING IS ENCLOSED | | | BY A WALL AND DOOR. | | | | | | 4) ELECTRICAL CODE REQUIRES SMOKE | | | DETECTORS AND ARC FAULT PROTECTED | | | CIRCUITS IN BEDROOMS. | | | | | | 5) INTERIOR WALL AND FLOOR FINISHES | | | SHALL COMPLY WITH CHAPTER 8 OF THE 2004 | | | FBC. | | | | | | 6) THIS PROJECT IS LOCATED IN AN R2 | | | CONDO AND NOT AN R3 ONE OR TWO FAMILY | | | RESIDENCE AND DOES NOT QUALIFY FOR THE | | | OWNER BUILDER EXCEPTION, THEREFORE, A | | | LICENSED CONTRACTOR IS REQUIRED TO PULL | | | A PERMIT FOR THIS PROJECT. SEE ATTACHED | | | COPY OF STATE STATUTE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-02 |
Time |
14:25 |
Rev Time |
0.45 |
| Received By |
rmcdouga |
Date |
2006-03-02 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2006-03-02 00:00:00 | SEE NOTES ON PLANSJL |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-02-23 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-23 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | DENIED: | | | | | | 1) SHALL COMPLY WITH NFPA 101 LIFE | | | SAFETY CODE 2003 EDITION. | | | | | | 2) INTERIOR FINISH FOR WALL AND CEILING | | | SHALL COMPLY WITH SECTION 10.2, AND | | | SHALL BE CLASS A, CLASS B, OR CLASS C. | | | | | | 3) SEPARATE SHOP DRAWING AND PERMIT | | | APPLICATION ARE REQUIRED FOR FIRE | | | SPRINKLER SYSTEM REMODEL. | | | | | | 4)PLEASE VERIFY AND CONFIRM THAT THE | | | CLOSET IS LESS THAN 12 SQ FT. IF NOT IT | | | IS REQUIRED TO BE FIRE SPRINKLER | | | PROTECTED. | | | | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-01 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-09 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2006-02-09 00:00:00 | TO "BOB"#6 |
|
|
|