Plan Review Details - Permit 06020225
Plan Review Stops For Permit 06020225
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-27 Cont ID  
Sent By alange Date 2006-03-27 Time 07:53 Rev Time 2.50
Received By alange Date 2006-03-24 Time 14:11 Sent To  
Notes
2006-03-27 00:00:00 
 DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE HAS BEEN REVISED TO $.
 ADDITIONAL PERMIT FEES ARE DUE.
  
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR
 ROOFING, DOORS, WINDOWS, IMPACT
 PROTECTION AND STRAPS AND TIE-DOWNS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 10. MINIMUM FOOTING DEPTH IS 12" BELOW
 GRADE R-403.1.4
  
 11.SHOW NAILING SCHEDULE FOR T 1-11
 SIDING.
  
 12.BOTH PLANS SETS SHALL BE SIGNED AND
 SEALED.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-02-17 Cont ID  
Sent By btrobaug Date 2006-02-17 Time 13:31 Rev Time 0.50
Received By btrobaug Date 2006-02-17 Time 13:17 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-10 Cont ID  
Sent By adarroug Date 2006-03-10 Time 16:51 Rev Time 0.00
Received By adarroug Date 2006-03-10 Time 16:51 Sent To B
Notes
2006-03-24 00:00:00PLANS IN RES BOX
2006-03-10 00:00:00TO "ALANGE" DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-13 Cont ID  
Sent By adarroug Date 2006-02-13 Time 09:52 Rev Time 0.00
Received By adarroug Date 2006-02-13 Time 09:52 Sent To E
Notes
2006-02-13 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-27 Cont ID  
Sent By alange Date 2006-03-27 Time 07:59 Rev Time 0.00
Received By alange Date 2006-02-07 Time 14:29 Sent To  
Notes
2006-02-07 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-17 Cont ID  
Sent By tgordon Date 2006-02-17 Time 13:48 Rev Time 0.15
Received By tgordon Date 2006-02-17 Time 13:48 Sent To B
Notes
2006-02-17 00:00:00*** DENIED ***
 1) ONLY ONE SET OF PLANS HAVE
 ARCHITECT'S SEAL ON THEM, BOTH SETS NEED
 TO BE SEALED.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-10 Cont ID  
Sent By mmclean Date 2006-02-10 Time 16:43 Rev Time 0.00
Received By mmclean Date 2006-02-10 Time 16:43 Sent To I
Notes
2006-02-10 00:00:00DENIED,
 1. NEED TO PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE PROPOSED WORK
 (FLORIDA ROOM) WITH SETBACKS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720