Plan Review Details - Permit 06020161
Plan Review Stops For Permit 06020161
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-09-05 Cont ID  
Sent By amorse Date 2006-09-05 Time 11:50 Rev Time 0.00
Received By amorse Date 2006-09-05 Time 11:50 Sent To PC
Notes
2006-09-05 00:00:00 
  
 REVISION
  
 ONLY FOR TRUSS LAYOUT CHANGE THIS
 DRAWING IS NOT THE ENGINEERED TRUSS
 DRAWINGS THAT ARE REQUIRED TO BE
 SUBMITTED

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-09-01 Cont ID  
Sent By amorse Date 2006-09-01 Time 15:03 Rev Time 0.00
Received By amorse Date 2006-09-01 Time 15:03 Sent To  
Notes
2006-09-05 00:00:00 
  
 PROVISO
  
 SIGNED AND SEALED TRUSS ENGINEERING
 REQUIRED PRIOR TO TRUSS FRAMING
 INSPECTION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-08 Cont ID  
Sent By amorse Date 2006-05-08 Time 13:44 Rev Time 1.00
Received By amorse Date 2006-05-08 Time 13:44 Sent To PC
Notes
2006-05-08 00:00:00 
  
 DENIED
  
 **** NOTES 1&7 WERE NOT ADDRESSED****
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 7) THEIR ARE 2 PRODUCT APPROVALS FOR
 SHINGLES (TAMKO AND OWENS CORNING)
 SUBMIT ONLY THE ONE YOU WILL BE USING.
 ALSO THEIR ARE 2 PRODUCT APPROVALS FOR
 SINGLE HUNG WINDOWS (PGT AND YALE OGRON)
 PLEASE SUBMIT ONLY THOSE WHICH APPLY IF
 BOTH ARE USED SPECIFY WHERE ON THE
 DRAWING
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-24 Cont ID  
Sent By amorse Date 2006-03-24 Time 10:53 Rev Time 4.00
Received By amorse Date 2006-03-24 Time 10:53 Sent To PC
Notes
2006-03-24 00:00:00 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 3) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC
  
 4) MIN R VALUE OF A CEILING UNDER ATTIC
 IS R30 PER 13-604 AND THE TABLES OF
 APPENDIX 13-D ADJUST DRAWINGS AND ENERGY
 CALCS TO COMPLY
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6) SUBMIT PRODUCT APPROVALS FOR WOOD
 CONNECTORS, STRAPS, TIES, ETC.
  
 7) EXTRA PRODUCT APPROVAL WERE SUBMITED
 ARE THESE TO BE USED? IF NOT REMOVE FROM
 SUBMITAL DOCUMENTS
  
 8) SHUTTER PRODUCT APPROVAL SHALL HAVE
 ATTACMENT TYPE, ANCHOR TYPE, ETC. MARKED
 ON NOA AND A KEY PLAN WITH LOCATION OF
 OPENINGS, PANEL #'S, EGRESS, ETC. SEE
 ATTACHED SHEDULE FOR INFORMATION
 REQUIRED
  
 9) NOTE AT BOTTOM OF 1/3 NOT IN 2004 FBC
 PLEASE CHECK EXISTING BUILDING CODE 2004
 FOR REFERENCE. SMOKE DETECTOR SHALL BE
 REQUIRED PER R313.1.1
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-01 Cont ID  
Sent By btrobaug Date 2006-05-01 Time 10:25 Rev Time 0.33
Received By btrobaug Date 2006-05-01 Time 10:05 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-02-17 Cont ID  
Sent By btrobaug Date 2006-02-17 Time 13:12 Rev Time 0.50
Received By btrobaug Date 2006-02-17 Time 12:19 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-26 Cont ID  
Sent By adarroug Date 2006-08-26 Time 13:52 Rev Time 0.00
Received By adarroug Date 2006-08-26 Time 13:52 Sent To B
Notes
2006-08-26 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 08:49 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 08:49 Sent To E
Notes
2006-04-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-13 Cont ID  
Sent By adarroug Date 2006-02-13 Time 08:32 Rev Time 0.00
Received By adarroug Date 2006-02-13 Time 08:32 Sent To E
Notes
2006-02-13 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-24 Cont ID  
Sent By amorse Date 2006-03-24 Time 10:53 Rev Time 0.00
Received By amorse Date 2006-02-07 Time 11:20 Sent To  
Notes
2006-02-07 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-05-01 Cont ID  
Sent By tgordon Date 2006-05-01 Time 14:06 Rev Time 0.30
Received By tgordon Date 2006-05-01 Time 14:06 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-17 Cont ID  
Sent By tgordon Date 2006-02-17 Time 14:35 Rev Time 0.30
Received By tgordon Date 2006-02-17 Time 14:35 Sent To P
Notes
2006-02-17 00:00:00*** DENIED ***
 1)ENERGY CALCULATIONS NEED TO BE ON FORM
 600A-04 (2004) PER FBC 13-600.3.A .
  
 2) PLEASE SHOW ON MECHANICAL PLANS
 CLOTHS DRYER VENT, A/C COPPER LINES AND
 SIZES, AND CONDENSATE DRAIN LINE
 TERMINATION.
  
 3) PLEASE STATE ON THE MECHANICAL PLANS
 THAT THE A/C SYSTEM FOR THE EXISTING
 HOUSE WILL BE REMOVED, AND THE NEW A/C
 SYSTEM IN THE ADDITION WILL ALSO BE
 SUPPLYING A/C TO THE EXISTING HOUSE A/C
 DUCTS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-05 Cont ID  
Sent By jleech Date 2006-05-05 Time 10:09 Rev Time 0.00
Received By jleech Date 2006-05-05 Time 10:09 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-21 Cont ID  
Sent By jleech Date 2006-02-21 Time 08:52 Rev Time 0.00
Received By jleech Date 2006-02-21 Time 08:52 Sent To B
Notes
2006-02-21 00:00:00DENIED;
 1.HORIZONTAL DRY VENTS ARE NOT PERMITED
 SEE FBC-2004 RESIDENTIAL SEC. P3104.3.
 2.TUB IS NOT VENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2006-02-10 Cont ID  
Sent By mmclean Date 2006-02-10 Time 14:35 Rev Time 0.00
Received By mmclean Date 2006-02-10 Time 14:35 Sent To I
Notes
***NONE***