Plan Review Details - Permit 06020160
Plan Review Stops For Permit 06020160
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-04-24 Cont ID  
Sent By kconrad Date 2006-04-24 Time 15:33 Rev Time 0.00
Received By kconrad Date 2006-04-24 Time 14:37 Sent To I
Notes
2006-04-24 00:00:00PROJECT:2000 SOUTH DIXIE HIGHWAY
 CAREFREE THEATRE
  
 PERMIT:COMMERCIAL/BUILDING
  
 RECEIVED REVISED PLAN. ALL PRIOR ITEMS
 NOTED WERE CORRECTED.
  
 PROVISO:
  
 1)INDICATE NEW WALL FOUNDATION
 REINFORCING STEEL:REQUIRE CLARIFICATION
 LETTER FROM EOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-23 Cont ID  
Sent By kconrad Date 2006-03-23 Time 18:53 Rev Time 0.00
Received By kconrad Date 2006-03-21 Time 20:03 Sent To  
Notes
2006-03-23 00:00:00CAREFREE THEATRE
 2000 SOUTH DIXIE HIGHWAY
  
 CONTRACTOR:SEALTITE ROOFING
  
 CONTACT:DERMIT BEGLEY 631.258.0846
  
 1)STRUCTURAL REPAIR/ALTERATIONS MUST
 CONFORM TO THE FBC EXISTING BUILDINGS,
 SECTION 407.3.1/607.3-REPAIR/LEVEL 2
 ALTERATIONS CONSECUTIVELY.
  
  
 BUILDING PLAN REVIEW/REVISION #1:FAILED
  
 1)REQUIRE ADDITIONAL DETAILS FOR THE
 REINFORCING DOWEL EMBEDMENT LENGTH AND
 TYPE OF EPOXY TO BE UTILIZED.
  
 2)SPECIFY GRADE AND VERTICAL LAP SPLICES
 OF THE REINFORCING STEEL.FBC2101.3
  
 3)INDICATE TYPE AND STRENGTH OF GROUT TO
 BE PLACED IN CMU'S.
  
 4)INDICATE CMU MORTAR TYPE.
  
 5)FLOOR PLAN OF RETAIL SECTION
 INDICATING LOCATION OF REPAIR.
  
 6)REQUIRE EXTERIOR DOOR PRODUCT
 APPROVALS AT NEW OPENING IN WALL.
  
 7)SPECIFY EXTERIOR WALL COVERING.FBC
 1405.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-02-06 Cont ID  
Sent By kconrad Date 2006-02-06 Time 10:36 Rev Time  
Received By kconrad Date   Time   Sent To I
Notes
2006-02-06 00:00:00PROVISO:
  
 THIS PERMIT IS ISSUED DUE TO AN
 EMERGENCY/LIFE SAFETY CONDITION:THE
 SOUTHWEST WALL HAS BEEN STRUCTURALLY
 COMPROMISED.
  
 IT WAS ALSO OBSERVED THAT THERE MAY BE
 ASBESTOS MATERIAL WITHIN THE AREA OF THE
 DEMOLITION:REQUIRE THE SUBMITTAL OF A
 PRELIMINARY ASBESTOS REPORT. THIS
 MATERIAL MAY ONLY BE DISTURBED BY A
 CERTIFIED/LICENSED ABATEMENT
 CONTRACTOR.PLEASE REVIEW FBC 105.3.6.OK
 TO ISSUE AS PROVISO PER ROBERT B.
 REQUIRE ASBESTOS NOTIFICATION
 STATEMENT.IT IS THE OWNER/OPERATOR'S
 RESPONSIBILITY TO COMPLY WITH THE
 PROVISIONS OF THE FLORIDA STATUES
 469.003.SEE FBC 105.9.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-12 Cont ID  
Sent By adarroug Date 2006-04-12 Time 09:58 Rev Time 0.00
Received By adarroug Date 2006-04-12 Time 09:58 Sent To B
Notes
2006-04-12 00:00:00TO "KCONRAD" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-20 Cont ID  
Sent By ptjomsto Date 2006-03-20 Time 09:48 Rev Time 0.00
Received By ptjomsto Date 2006-03-20 Time 09:48 Sent To  
Notes
2006-03-20 00:00:00REV/BLDG GIVEN TO KEN CONRAD

Review Stop Z ZONING
Rev No 1 Status N Date 2006-02-06 Cont ID  
Sent By kconrad Date 2006-02-06 Time 11:04 Rev Time 0.00
Received By kconrad Date 2006-02-06 Time 11:04 Sent To  
Notes
***NONE***