| Plan Review Stops For Permit 06020067 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-27 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-27 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-16 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-16 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2006-03-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)SHEET LS2.0, PLEASE DECLARE | | | BUILDING TYPE IA OR IB, FBC TABLE 601. | | | | | | NOT ADDRESSED.AS DISCUSSED WITH THE | | | ARCHITECT, THIS MAY BE DONE IN THE FORM | | | OF A LETTER. | | | | | | 3.)ADDRESSED. | | | | | | 4.)DOCUMENTS PREPARED BY AN INTERIOR | | | DESIGNER AND SUBMITTED FOR PUBLIC RECORD | | | ARE TO BE SIGNED, SEALED, AND DATED | | | ORIGINALS, FAC61G1-16.003.AN INTERIOR | | | DESIGN BUSINESS LICENSE IS REQUIRED FOR | | | CORPORATE INTERIORS INC.EACH SHEET IS | | | TO CONTAIN ALL INFORMATION REQUIRED BY | | | FAC61G1-16.004. | | | | | | THE TITLE BLOCK IS NOW IN COMPLIANCE BUT | | | THE SEAL IS TO LEAVE AN IMPRESSION | | | FAC61G16-23.001.AN INK SEAL WAS | | | PROVIDED FOR THE INTERIOR DESIGNER. | | | | | | 5.) (NEW COMMENT.)SEE MECHANICAL | | | COMMENTS IN REGARDS TO PENETRATIONS | | | THROUGH THE 2 HOUR WALL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-02-27 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-02-26 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)SHEET LS2.0, PLEASE DECLARE | | | BUILDING TYPE IA OR IB, FBC TABLE 601. | | | | | | 3.)CORRIDOR 813 SHOWS A DISTANCE OF | | | 53FT, CORRIDOR 871 SHOWS 60FT, BOTH | | | WHICH EXCEED THE 50FT MAX FOR A DEAD END | | | CORRIDOR FBC1016.3. | | | | | | 4.)DOCUMENTS PREPARED BY AN INTERIOR | | | DESIGNER AND SUBMITTED FOR PUBLIC RECORD | | | ARE TO BE SIGNED, SEALED, AND DATED | | | ORIGINALS, FAC61G1-16.003.AN INTERIOR | | | DESIGN BUSINESS LICENSE IS REQUIRED FOR | | | CORPORATE INTERIORS INC.EACH SHEET IS | | | TO CONTAIN ALL INFORMATION REQUIRED BY | | | FAC61G1-16.004. | | | | | | 5.)INTERIOR FINISHES ARE TO COMPLY | | | WITH FBC803.5, NFPA75-5.3.1.2.1.NOTE | | | DESIGN CRITERIA ON THE PLAN. | | | | | | 6.)SHEET 8.08A, PREPARED BY THE | | | INTERIOR DESIGNER, SHOWS WOOD BLOCKING. | | | SEE FBC717.5, FBC603 AND REVISE TO SHOW | | | COMPLIANCE. | | | | | | 7.)THE BREAK ROOM SINKS ARE TO COMPLY | | | WITH FBC11-4.24.THE SINK IS TO BE | | | ACCESSIBLE AND IS REQUIRED TO HAVE THE | | | KNEE CLEARANCE FBC11-4.24.3.CABINET | | | DOORS ARE SHOWN ON THE PLAN. | | | | | | 8.)CORRIDOR 832 IS OPEN TO RECORDS | | | STORAGE 864.FBC1002, THE CORRIDOR | | | SHOULD BE ENCLOSED. | | | | | | 9.)SHOW FIRE PROTECTION FOR COMPUTER | | | ROOM 860, WALLS AND OPENINGS, NFPA75 | | | 5.1.3. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-14 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-14 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-24 |
Time |
20:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-24 |
Time |
19:08 |
Sent To |
B |
|
| Notes |
| 2006-02-24 00:00:00 | ******** UNSAT ********* | | | | | | 1)NOTE: PLEASE REFERENCE ALL CURRENT | | | CODE IN EFFECT FOR PLANS AND DESIGN. | | | PLEASE SEE LOCATIONS ON PLANS WHICH | | | REFLECT THE 2001 FBC ETC. | | | ** PLEASE REFERENCE THE FOLLOWING: | | | 2003 NFPA-101, 2002 NFPA-72, 2002 | | | NFPA-70, AND 2004 FBC. | | | | | | 2)NOTE: PLEASE SEE NEC 645 AND NFPA-75 | | | FOR ALL THE REQUIREMENTS WHICH WILL NEED | | | TO BE ADJUSTED ON PLANS. | | | PLEASE SEE 645.5,645.7,645.10 ETC | | | PLEASE ADJUST LOADS FOR EQUIPMENT.645.5 | | | ** PLEASE SEE OTHER REVIEWS AND PLEASE | | | BE SURE TO ADJUST MECH, AND BLDG PLANS | | | ACCORDINGLY. | | | | | | 3)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215.3,230.42 ETC | | | | | | 4)NOTE: PLEASE PROVIDE GROUNDING | | | ELECTRODE CONNECTION FOR TRANSFORMER, | | | PER 250.30 AND 250.58 | | | | | | 5)NOTE: PLEASE CLARIFY EQUIPMENT | | | GROUNDING METHOD BETWEEN NEW 400A MIAN | | | AND MDP-1. | | | 250.110,250.122 | | | | | | 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT PER 110.9, | | | 215.5 | | | ** IT IS NOTED THESE ARE SHOWN FOR | | | PANELS,HOWEVER PLEASE PROVIDE FOR NEW | | | MAIN DISCONNECT. | | | | | | 7)NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITING OF EM LTS WHICH REQUIRES THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | ** PLEASE KNOW, IF THESE THE LIGHTING IN | | | THE ARE OF FLOOR GOES OUT, NO MEANS OF | | | EGRESS LIGHTING WOULD BE PROVIDED AS THE | | | EM WOULD NOT COME ON UNLESS BLDG | | | ELECTRICAL UTILITY SERVICES FAILS. THIS | | | WOULD LEAVE ANY ONE AREA /FLOOR IN TOTAL | | | DARKNESS. PLEASE EITHER ADD ADDTIONAL | | | BATTERY BACK UP FIXTURES TO AREA FOR | | | EGRESS, PLACE FIXTURES SHOWN ON LOCAL | | | CIRCUITS. | | | 700.12,NFPA-101,7.8,7.9.2.2 | | | | | | 8)NOTE: PLEASE SEE 2004 FBC CHAPTER 13 | | | FOR COMMERCIAL BLDGS AND THE ENERGY CODE | | | FOR PLANS AND DESIGS. IT IS NOTED, SOME | | | MD/ ARE NOTED, HOWEVER PLEASE PROVIDE AL | | | INFORMATION AS FOLLOWS AND COMPLETE | | | PLANS FOR LAYOUTS, SCHEDULING,VOLTAGE | | | DROPS, OVER-RIDES, SPACE | | | CONTROLS,CALCULATIONS ETC. | | | PLEASE SEE : | | | 13-415.1.ABC.1.1, 13-415.1.ABC.1.2, | | | 13-413.1.ABC.1.1 & .1.2, 13-415.1.ABC.1, | | | | | | &.1.1 | | | PLEASE SEE ALL DESIGNS SHALL MEET 2004 | | | FBC. | | | PLEASE ALSO SEE COMPLETION DOC'S | | | REQUIRED 13-413.1.ABC.2.1.&.2 | | | ** PLEASE KNOW, SPEC SHEETS ON DEVICES, | | | AND SYSTEM BEING INSTALLED WILL BE | | | REQUIRED TO BE SUBMITTED, PLEASE PROVIDE | | | A MIN OF TWO COPIES. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS | | | FROM OTHER TRADES WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-24 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-24 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2006-03-24 00:00:00 | SHEETS STAMPED 3/24/06 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-14 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-14 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-03-14 00:00:00 | ******PROVISO****** | | | | | | 1) PLEASE SEE COMMENT FROM MECHANICAL | | | PLAN REVIEW REF: FIRE DAMPERS. | | | | | | 2) PLANS RED LINES REGARDING CORRECTED | | | CODE SECTION. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-02-14 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-13 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2006-02-14 00:00:00 | DENIED: | | | | | | 1) SHALL COMPLY WITH NFPA 101 LIFE | | | SAFETY CODE 2003 EDITION AND NFPA 1 | | | UNIFORM FIRE CODE 2003 EDITION. | | | | | | 2) CORRIDOR # 813 APPEARS TO EXCEED 50 | | | FEET TRAVEL DISTANCE FOR DEAD-END | | | CORRIDORS CHAPTER 38.2.5.2.1, NFPA 101. | | | | | | 3) FIRE ALARM NOTE # 17 HVAC DUCT SMOKE | | | DETECTORS SHALL BE CONNECTED TO THE FIRE | | | ALARM CONTROL PANEL AND SHALL INITIATE A | | | GENERAL FIRE ALARM SIGNAL, NOT A | | | SUPERVISORY SIGNAL. | | | | | | 4) DELAYED-EGRESS LOCKS SHALL COMPLY | | | WITH NFPA 101 CHAPTER 7.2.1.6.1, AND | | | ACCESS-CONTROLLED EGRESS DOORS SHALL | | | COMPLY WITH NFPA 101 CHAPTER 7.2.1.6.2. | | | | | | 5) SEPARATE SHOP DRAWING AND PERMIT | | | APPLICATION ARE REQUIRED FOR FIRE ALARM | | | SYSTEM REMODEL. | | | | | | 6) SEPARATE SHOP DRAWING AND PERMIT | | | APPLICATION ARE REQUIRED FOR FIRE | | | SPRINKLER SYSTEM REMODEL. | | | | | | 7) INTERIOR WALL AND CEILING FINISH | | | MATERIAL COMPLYING WITH NFPA 101 SECTION | | | 10.2 SHALL CLASS A OR CLASS B IN EXITS | | | AND IN EXIT ACCESS CORRIDORS. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-04 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-04 |
Time |
15:58 |
Sent To |
M |
|
| Notes |
| 2006-11-04 15:58:58 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-28 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-28 |
Time |
16:09 |
Sent To |
P |
|
| Notes |
| 2006-03-28 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
20:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-21 |
Time |
20:08 |
Sent To |
|
|
| Notes |
| 2006-03-21 00:00:00 | SENT TO BOB BOARD # 7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2006-03-09 00:00:00 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-02-27 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-02-02 |
Time |
18:05 |
Sent To |
|
|
| Notes |
| 2006-02-02 00:00:00 | *EXPIDITED PLAN* OK TO ROUTE TO "BOB" | | | PER RBROWN. | | | | | | TO "BOB"#18 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-15 |
Time |
10:31 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-11-15 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2006-11-15 10:38:22 | REVISION TO MECH. PLANS PAGE M0.2, M2.1, AND M2.2 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-22 |
Time |
12:32 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-03-22 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-14 |
Time |
12:25 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-03-14 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2006-03-14 00:00:00 | *** DENIED *** | | | 1) AS STATED IN LAST REVIEW 02-13-06 #3. | | | FIRE DAMPERS ARE REQUIRED WHERE DUCTS | | | ARE PENETRATEING THE FIRE RATED WALLS TO | | | COURT ROOMS (847 & 838) PER 2004 FBC | | | 716.5.1 . PLEASE SEE TRANSFER RETURN AIR | | | DUCT FROM COURTROOM 847 TO ROOM 873; | | | RETURN AIR DUCT FROM COURTROOM 847 TO | | | ROOM 845; TRANSFER RETURN AIR DUCT FROM | | | COURTROOM 838 TO ROOM 872; AND RETURN | | | AIR DUCT FROM COURTROOM 838 TO ROOM 836. | | | PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-13 |
Time |
10:43 |
Rev Time |
3.00 |
| Received By |
tgordon |
Date |
2006-02-13 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | *** DENIED *** | | | 1) PLEASE PROVIDE ENERGY CALCULATIONS, | | | PER 2004 FBC CHAPTER 13. | | | | | | 2) PLEASE SHOW ON MECH. PLANS HOW AIR | | | CONDITIONING IS PROVIDED FOR ROOM 860 | | | (THE COMPUTER ROOM). | | | | | | 3) FIRE DAMPERS ARE REQUIRED WHERE DUCTS | | | ARE PENETRATEING THE FIRE RATED WALLS TO | | | COURT ROOMS (847 & 838), PER 2004 FBC | | | 716.5.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-30 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-30 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-22 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-03-22 00:00:00 | DENIED; | | | 1. WATER LINES STILL NOT SHOWN TO MOP | | | SINK, PAGE P3.2. | | | 2.WATER HEATER PAN DRAIN CANNOT | | | DISCHARGE INTO STORM WATER RISER. SEE | | | FBC-2004 PLUMBING SEC.504.7.2 PAN DRAIN | | | TERMINATION, MUST DISCHARGE OVER AN | | | INDIRECT RECEPTOR OR EXTERIOR OF | | | BUILDING. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-13 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-13 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | DENIED; | | | 1.WATER HEATER PAN DRAIN IS NOT SHOWN ON | | | PAGE P-2.1 AS NOTED ON WATER HEATER | | | DETAIL. MECHANICAL ROOM IS SHOWN ON PAGE | | | P-2.2. AND NO SANITARYDRAINAGE IS | | | SHOWN. A FLOOR DRAIN SHOULD NOT BE USED | | | IN A MECHANICAL ROOM BECAUSE THE TRAP | | | WOULD BE SUBJECT TO A PNEUMATIC PRESSURE | | | DIFFERENTIAL OF MORE THAN ONE INCH OF | | | WATER COLUMN. FBC-2004 PLUMBING SEC. | | | 901.2. | | | 2.PAGE P-5.1 SANITARY AND WATER RISER | | | DIAGRAMS SHOW A MOP SINK. PAGE P-2.1, | | | SANITARY FLAT DRAWING, SANITARY PIPING | | | NOT SHOWN. PAGE P-3.2 WATER PIPING NOT | | | SHOWN TO MOP SINK. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-11 |
Time |
06:17 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-11 |
Time |
06:17 |
Sent To |
|
|
| Notes |
| 2006-02-11 00:00:00 | | | | PLUMBING PLAN REVIEW EXAMINER | | | PAUL SCHMITZ 561-805-6692 | | | [email protected] | | | FBC PLUMBING 2004 | | | FBC FUEL GAS 2004 | | | FBC 2004 BUILDING CH 11 | | | DENIED | | | 1)SHT 8.10 DETAIL (E) | | | BREAK ROOMS #863,815,827. | | | BASE CABINET DOORS UNDER SINKS. | | | SINKS | | | 11-4.24.1 GENERAL. | | | SINKS REQUIRED TO BE ACCESSIBLE BY | | | SECTION 11-4.1 SHALL COMPLY WITH SECTION | | | 11-4.24. | | | | | | 11-4.24.3 KNEE CLEARANCE. | | | KNEE CLEARANCE THAT IS AT LEAST 27 | | | INCHES (685 MM) HIGH, 30 INCHES (760 MM) | | | WIDE, AND 19 INCHES (485 MM) DEEP SHALL | | | BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.4 DEPTH. | | | EACH SINK SHALL BE A MAXIMUM OF 6? | | | INCHES (165 MM) DEEP. | | | 11-4.24.5 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES | | | BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE | | | PROVIDED IN FRONT OF A SINK TO ALLOW | | | FORWARD APPROACH. THE CLEAR FLOOR SPACE | | | SHALL BE ON AN ACCESSIBLE ROUTE AND | | | SHALL EXTEND A MAXIMUM OF 19 INCHES (485 | | | MM) UNDERNEATH THE SINK (SEE FIGURE | | | 11-32). | | | 11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED UNDER | | | SINKS SHALL BE INSULATED OR OTHERWISE | | | CONFIGURED SO AS TO PROTECT AGAINST | | | CONTACT. THERE SHALL BE NO SHARP OR | | | ABRASIVE SURFACES UNDER SINKS. | | | 11-4.24.7 FAUCETS. | | | FAUCETS SHALL COMPLY WITH SECTION | | | 11-4.27.4. LEVER-OPERATED, PUSH-TYPE, | | | TOUCH-TYPE, OR ELECTRONICALLY CONTROLLED | | | MECHANISMS ARE ACCEPTABLE DESIGNS. | | | | | | 2)PRIVATE TOILET ROOM #818 | | | SECTION 11-4.1.3 | | | 11) TOILET FACILITIES. IF TOILET ROOMS | | | ARE PROVIDED, THEN EACH PUBLIC AND | | | COMMON USE TOILET ROOM SHALL COMPLY WITH | | | SECTION 11-4.22. OTHER TOILET ROOMS | | | PROVIDED FOR THE USE OF OCCUPANTS OF | | | SPECIFIC SPACES (I.E., A PRIVATE TOILET | | | ROOM FOR THE OCCUPANT OF A PRIVATE | | | OFFICE) SHALL BE ADAPTABLE. IF BATHING | | | ROOMS ARE PROVIDED, THEN EACH PUBLIC AND | | | COMMON USE BATHROOM SHALL COMPLY WITH | | | SECTION 11-4.23. ACCESSIBLE TOILET ROOMS | | | AND BATHING FACILITIES SHALL BE ON AN | | | ACCESSIBLE ROUTE. | | | 11-4.22.2 DOORS. | | | (1) ALL DOORS TO ACCESSIBLE TOILET ROOMS | | | SHALL COMPLY WITH SECTION 11-4.13. DOORS | | | SHALL NOT SWING INTO THE CLEAR FLOOR | | | SPACE REQUIRED FOR ANY FIXTURE. | | | | | | 3) SHT P-01 WATER HEATER DETAIL | | | 607.3 THERMAL EXPANSION CONTROL. | | | A MEANS OF CONTROLLING INCREASED | | | PRESSURE CAUSED BY THERMAL EXPANSION | | | SHALL BE PROVIDED WHERE REQUIRED IN | | | ACCORDANCE WITH SECTIONS 607.3.1 AND | | | 607.3.2. | | | 607.3.1 PRESSURE-REDUCING VALVE. | | | FOR WATER SERVICE SYSTEM SIZES UP TO AND | | | INCLUDING 2 INCHES (51 MM), A DEVICE FOR | | | CONTROLLING PRESSURE SHALL BE INSTALLED | | | WHERE, BECAUSE OF THERMAL EXPANSION, THE | | | PRESSURE ON THE DOWNSTREAM SIDE OF A | | | PRESSURE-REDUCING VALVE EXCEEDS THE | | | PRESSURE-REDUCING VALVE SETTING. | | | | | | 4)SHT-5.1 DOMESTIC WATER ISOMETRIC | | | AIR CHAMBERS NOT APPROVED | | | 604.9 WATER HAMMER. | | | THE FLOW VELOCITY OF THE WATER | | | DISTRIBUTION SYSTEM SHALL BE CONTROLLED | | | TO REDUCE THE POSSIBILITY OF WATER | | | HAMMER. A WATER-HAMMER ARRESTOR SHALL BE | | | INSTALLED WHERE QUICK-CLOSING VALVES ARE | | | UTILIZED. WATER-HAMMER ARRESTORS SHALL | | | BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER?S SPECIFICATIONS. | | | WATER-HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010. | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | | | |
|
|