| Plan Review Stops For Permit 06011202 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-10-04 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-10-04 |
Time |
07:10 |
Sent To |
PC |
|
| Notes |
| 2006-10-04 00:00:00 | | | | | | | *****REVISION***** | | | | | | REVISED DRAWINGS TO SHOW NEW PATIO SLAB |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-08-02 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-08-02 |
Time |
11:03 |
Sent To |
PC |
|
| Notes |
| 2006-08-02 00:00:00 | | | | | | | **************REVISION************* | | | ADD A PATIO SLAB |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-04-21 |
Time |
12:33 |
Rev Time |
0.75 |
| Received By |
amorse |
Date |
2006-04-21 |
Time |
12:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-04-18 |
Time |
06:48 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2006-04-18 |
Time |
06:48 |
Sent To |
PC |
|
| Notes |
| 2006-04-18 00:00:00 | | | | | | | DENIED | | | | | | 1) THREE PRODUCT APPROVALS NEED TO BE | | | CORRECTED | | | A) TYPE OF ASPHALT SHINGLES TO BE USED | | | (EG. OAKRIDGE PRO 30 AR, SUPREME AR, | | | ETC.) AND THE INSTALLATION DOCUMENTS | | | THAT REFFER TO THAT SHINGLE | | | B) UPDATED SHUTTER COVER AND DRAWINGS | | | THAT ARE ATTACHED TO COVERS PDF FILE. | | | PLEASE SPECIFY THE GAUGE USED AND THE | | | METHOD OF ATTACHMENT | | | C) HORIZONTAL SLIDER COVER SHEET AND | | | PRODUCT NOA DONOT MATCH | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-03-21 |
Time |
09:26 |
Rev Time |
2.00 |
| Received By |
amorse |
Date |
2006-03-21 |
Time |
09:26 |
Sent To |
PC |
|
| Notes |
| 2006-03-21 00:00:00 | | | | | | | DENIED | | | | | | 1) GLASS BLOCK WILL REQUIRE IMPSCT | | | PROTECTION PER 1609.1.4 FBC SUBMIT | | | PRODUCT APPROVALS FOR SHUTTERS | | | | | | 2) NO PRODUCT APPROVALS WERE SUBMITTED | | | FOR FRENCH DOORS OR HORIZONTAL SLIDER | | | | | | 3) ALL PRODUCT APPROVALS WERE SUBMITTED | | | WITH ONLY THE STATE COVER SHEETS PLEASE | | | SUMIT THE NOA'S, EVALUATION REPORTS | | | AND/OR INSTALLATIONSHEETS THAT GO WITH | | | THE COVER SHEET | | | | | | 4) TWO STATE COVER SHEETS FOR SHINGLES | | | FROM TWO DIFFERENT MANUFACTURERS PLEASE | | | CLARIFY | | | | | | 5) PRODUCT APPROVALS SHALL BE APPROVED | | | BY DESIGNER OF RECORD PER 106.3.3 FBC* | | | | | | 6) PROVIDE ENGINEERED TRUSS DRAWINGS | | | WITH SUBMITAL PER R802.10 FBC | | | | | | 7) PROVIDE ATTIC ACCESS LOCATION AND | | | SIZE ON DRAWINGS THAT COMPLY WITH R807.1 | | | ALSO SEE M/E 100 AS FLOURESCENT FIXTURE | | | MAY CROSS ACCESS | | | | | | 8) PROVIDE 2 COPIES OF ENERGY CALCS AND | | | MANUEL J | | | | | | 9) SHOW DETAIL OF NEW BEAM-EXISTING | | | TRUSS CONNECTION WITH LUS26 | | | | | | 10) PROVIDE FIN. FL. ELEVATION, BEAM | | | ELEVATION, ROOF PITCH AND ELAVATION, AND | | | MEAN ROOF HEIGHT ON A/200 | | | | | | 11) RADON FEE SHALL BE COLLECTED FOR THE | | | STATE ON SQUARE FOOTAGE BEING ADDED PER | | | 10D-91 FAC | | | | | | 12) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO A | | | PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-17 |
Time |
07:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-04-17 |
Time |
07:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-21 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-08-02 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
| 2006-03-22 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE GROUNDING ELECTRODE CONDUCTOR | | | MUST BE BONDED TO FOOTER STEEL PER | | | 250.52(A)(3). | | | | | | 2} THE SERVICE ENTRANCE CONDUCTORS ARE | | | TOO SMALL FOR A 200 AMP SERVICE. SEE | | | 310.16(B)(6). | | | | | | 3} PLEASE SUBMIT A PANEL SCHEDULE SO | | | THAT BRANCH CIRCUIT COMPLIANCE CAN BE | | | REVIEWED. | | | | | | 4} THE PLAN SHOWS AN ADDED A/C SYSTEM. | | | THIS NEEDS TO BE ADDED TO THE | | | CALCULATION, AND AT 100%, SEE 220.31(B). | | | | | | 5} THE BATH RECEPTACLES MUST BE GFI PER | | | 210.8(A)(1). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-03 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-03 |
Time |
14:27 |
Sent To |
B |
|
| Notes |
| 2006-10-03 00:00:00 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-08-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | SENT TO "AMORSE DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-28 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-28 |
Time |
14:23 |
Sent To |
Z |
|
| Notes |
| 2006-07-28 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-12 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-12 |
Time |
15:01 |
Sent To |
E |
|
| Notes |
| 2006-04-12 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-08 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-08 |
Time |
09:31 |
Sent To |
E |
|
| Notes |
| 2006-02-08 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-03-21 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-02-01 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2006-02-01 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-17 |
Time |
08:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-04-17 |
Time |
08:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-17 |
Time |
07:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-03-22 |
Time |
16:31 |
Sent To |
P |
|
| Notes |
| 2006-03-22 00:00:00 | *** DENIED *** | | | 1) NEED TO SUBMIT ENERGY CALCULATIONS, | | | PER 2004 FBC 13-600.0.ABC . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-17 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-17 |
Time |
07:16 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-22 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-02 |
Time |
08:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-30 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-30 |
Time |
11:33 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-07 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-07 |
Time |
11:20 |
Sent To |
I |
|
| Notes |
| 2006-02-07 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/GATE WITH EASEMENT APPROVAL FROM | | | THE CITY OF WEST PALM BEACH UTILITY DEPT |
|
|