| Plan Review Stops For Permit 06010861 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-01-24 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-01-24 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2007-01-24 13:35:58 | PERMIT APPLIED TO THE CORRECT ADDRESS 3230 COMMERCE | | | PL. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-10-02 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-10-02 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2006-10-02 00:00:00 | IF THE PERMIT IS NEEDED FOR THE PCN = | | | 74424301170000030 THEN THIS ADDRESS | | | :3230 COMMERCE PL WITH THE ABOVE PCN | | | MUST BE SPECIFIED ON THE APPLICATION. | | 2006-09-28 00:00:00 | NEEDS, AS OUR SYSTEM SHOWS 3222, YET | | | ARCHITECT'S RESPONSE MENTION ADDRESS | | | SHOULD BE 3230 AND THE ADDRESS ON PLANS | | | IS ALSO 3220. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-08-21 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-08-21 |
Time |
18:52 |
Sent To |
I |
|
| Notes |
| 2007-08-21 19:12:11 | REVISIONS FOR SHEETS T1.1 AND A1.1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-26 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-26 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-13 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-13 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2007-04-13 16:54:28 | | | | BUILDING COMMENTS | | | | | | | | | PLEASE SEE ELECTRICAL COMMENTS , ENERGY EFFICIENCY | | | REPORT SHALL BE CORRECTED BEFORE ISSUANCE OF BUILDING | | | PERMIT. | | | | | | | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-01-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-01-26 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-01-26 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-17 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-17 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-16 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-16 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-10-16 14:32:50 | DENIED | | | | | | THE SIGNATURE SEAL AND DATE OF THE ARCHITECT SHALL | | | APPEAR ON ALL PAGES OF ARCHITECTURAL DOCUMENTS FILED | | | FOR PUBLIC RECORD.FAC 61G1-16.003,FS 481.2055 | | | | | | ART LANGE | | | BUILING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-18 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2005 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.SEE GENERAL | | | NOTES #3. | | | | | | 4.SHOW CONSTRUCTION TYPE ON PLANS. | | | FBC 106.3.5IT APPEARS THE WRONG TYPE | | | HAS BEEN SELECTED, TYPE IV IS HEAVY | | | TIMBER CONSTRUCTION UNDER THE 2004 FBC. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-19 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-04-19 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2005 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 3.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | 4.SHOW CONSTRUCTION TYPE ON PLANS. | | | FBC 106.3.5 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-20 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-20 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2007-04-20 11:46:29 | *NEW PLANS SUBMITTED VIA FED-EX, REMOVED OLD SHEETS, | | | INSERTED NEW SHEETS. STAMPED ELECTRICAL SHEETS OK. | | | THE THIRD SET OF ELECTRICAL SHEETS SUBMITTED ARE | | | STAMPED FOR CONTRACTOR TO HAVE AN EXTRA COPY OF | | | ELECTRICAL SHEETS TO USE AT DISCRETION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-18 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-18 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2007-04-18 10:41:53 | ** UNSAT ** | | | | | | ** TEMPORARY FAILED STATUS | | | | | | | | | 1) NOTE: PLEASE SEE THE TWO NEW SETS SUBMITTED ARE NOT | | | COMPLETE WITH NEW SHEETS. ONE SET WHICH IS OK CONTAINS | | | SHEETS E1.0 DATED 3/6/07, 2.0 DATED 12/11/06 AND 2.1 | | | DATED 3/30/07, WHERE THE SECOND SET CONTAINS ONLY THE | | | FOLLOWING ELECTRICAL SHEETS, E1.0 DATED 12/11/06, AND | | | 2.1 DATED 3/30/07. | | | THE SECOND SET IS NOT COMPLETE WITH ALL THREE | | | ELECTRICAL SHEETS AND IT DOES NOT CONTAIN THE MOST | | | CURRENT SHEETS. | | | | | | ** PLEASE OVER-NIGHT ALL THREE NEW SIGNED, DATED SEALED | | | SHEETS FOR EACH SET. THESE MAY BE SENT TO THIS OFFICE | | | DIRECTLY. THIS REVIEWER WILL INSERT NEW SHEETS INTO | | | BOTH SETS FOR STAMPING. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | 200 2ND ST. #RD FLOOR. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-15 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-14 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2007-03-15 08:52:02 | ** UNSAT 7TH REVIEW ** | | | | | | 1) NOTE: PLEASE SEE AS NOTED IN THE PREVIOUS REVIEW, | | | THE ENERGY CALCULATIONS DO NOT CORRELATE WITH PLANS. | | | PLEASE SEE THE SQ FT ON THE CALCULATIONS DO NOT | | | CORRELATE WITH THE SQ FT AS SHOWN ON PLANS. | | | PLEASE SEE THAT THE SHEET CONTAINING THE LIGHTING HAS | | | NOW BEEN REVISED HOWEVER NO REVISION TO THE ENERGY | | | CALCULATIONS WAS DONE TO COORDINATE WITH PLANS AND | | | FIXTURE LEGEND FOR THE NUMBER OF FIXTURES AND THE | | | TOTALS ON THE POWER. | | | PLEASE SEE THE ENERGY CALCULATIONS ON ONE SHEET ARE | | | DIFFERENT THAN THAT OF THE SAME TOTAL ON ANOTHER | | | SHEET. | | | PLEASE SEE THE LIGHTING PLANS MENTIONS NOW THE 4-LAMP | | | FIXTURES ARE OMITTED, HOWEVER NOTE #3 ON PLANS STILL | | | INDICATES 4-LAMP FIXTURES ARE TO BE INSTALLED. | | | PLEASE SEE THE FIXTURE LEGEND WHICH STATES FOR FIXTURE | | | *L3*,3- 32WATT LAMPS= 85WATTS AS A TOTAL FOR EACH | | | FIXTURE. THE SAME FOR IS SAID FOR FIXTURE *L2* AND | | | FIXTURE *L1* WHICH DOES NOT STATE ANY WATTAGE OR | | | TYPE?? | | | PLEASE CLARIFY HOW THE FIXTURES CAN CONTAIN 3-32W LAMPS | | | AND IT ONLY ADDS UP TO 85WATTS OR THE 2-32W AMPS, WHICH | | | ARE SHOWN @60WATTS? (EFFICIENCY?) | | | | | | 2) NOTE: PLEASE KNOW AS PLANS WERE ORIGINALLY SUBMITTED | | | FOR PLAN REVIEW ONLY, THE FS 553.80(2)(B) DID NOT | | | APPLY. PLEASE KNOW IF PLANS ARE REJECT FOR THE SAME | | | COMMENT ON THE FOLLOWING REVIEW, A FEE FOR THE PLAN | | | REVIEW PORTION OF THE PERMIT FEE WILL BE ASSESSED. | | | PLEASE ALSO KNOW AT THIS TIME ONE SET OF PLANS AND | | | ENERGY CALCULATIONS ARE BEING RETAINED BY THIS OFFICE | | | FOR POSSIBLE REVIEW BY THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS. | | | | | | 3) NOTE: PLEASE SEE NEW SHEET A1.2 WAS NOT DATED BY THE | | | ARCHITECT ALONG WITH SHEET T1.1. THIS IS REQUIRED | | | WHETHER OR NOT COMMENT IS MADE BY OTHER TRADES. SHEET | | | A1.2 IS NEW IN SET. | | | FS 481.221 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-01 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-01 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2007-03-02 15:33:49 | ** NOTE ADDED. | | | | | | | | | REPLACED SHEET A1.2 THAT WAS REVISED FOR THE REFLECTED | | | CEILING PLAN NOW CONTAINS A "RUBBER STAMP" FOR THE | | | REQUIRED ORIGINAL SIGNTURE BY THE ARCHITECT PER FS | | | 481.221. INFORMED MR. IAN GUNTHER OF ARCHITECT'S OFFICE | | | THAT WE NEED NEW SIGNED, DATED AND SEALED SHEETS FOR | | | THIS. | | 2007-03-01 11:50:00 | *** UNSAT *** | | | | | | 1) NOTE:PLEASE SEE ENERGY CALCULATIONS HAVE NOW | | | CHANGED WITH THE LIGHTING LOADS. PLEASE SEE THE | | | PREVIOUS DESIGN WAS HIGHER, YET NO CHANGES TO LIGHTING | | | ON PLANS COULD BE FOUND TO DECREASE THIS NUMBER. | | | PLEASE SEE THE NUMBER FOR THE LIGHTING DESIGN NOW | | | EXCEEDS THAT OF THE ALLOWANCE PER 13-415.2.C AND THE | | | TABLES. | | | PLEASE SEE THE ALLOWANCE FOR LIGHTING DENSITIES IS | | | STATED IN THE FBC AS 1.0 PER SQ FT AND YET DESIGN IS | | | NOW SHOWN ABOVE. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-10 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-09 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2007-01-10 07:37:15 | | | | ** UNSAT *** | | | | | | | | | ** PLEASE SEE PROJECT HAS NOW BEEN CONVERTED TO A | | | PERMIT. | | | APIIED DATE FOR PERMIT IS NOW DECEMBER 19TH, 2006. | | | PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW STILL NEEDS | | | TO BE ADDRESSED. | | | | | | | | | 1) NOTE: PLEASE SEE NOTE #3 FROM PREVIOUS REVIEW. | | | PLEASE SEE THAT THE TIMES FOR MAXIMUM OVER RIDES TIMES | | | WERE GIVEN WHICH COME DIRECTLY FROM THE CODE SECTIONS | | | GIVEN; HOWEVER PLEASE SEE A TIME OF 1HR IS BEING STATED | | | FOR OCCUPANCY SENSOR TYPES OF DEVICES. | | | PLEASE SEE 13-415.1.ABC.1.1,.1.2 AND .1.3. (30MINS MAX | | | FOR OC SENSOR TYPES AND 4HRS MAXIMUM FOR TIMER TYPE | | | OVER RIDES. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED STILL DO | | | NOT INDICATE THE INFORMATION AS NEEDED TO COMPLY WITH | | | 13-415.1.AB.1, 13-415.2. | | | | | | ** PLEASE SEE THESE NOW INDICATE LIGHTING FOR OPERATING | | | ROOMS WHICH IF THIS FACILITY HAS "OPERATING ROOM", THEN | | | THIS ENTIRE PROJECT WOULD FALL UNDER DIFFERENT | | | REQUIREMENTS IN THE CODE AND WOULD NEED TO RE-DESIGN | | | ALL ELECTRICAL AS SHOWN FOR SUCH. | | | | | | ** PLEASE SEE ENERGY CALCULATIONS NOW DO NOT CONTAIN | | | ANY WATER HEATING SYSTEMS, WHICH ARE SHOWN ON PLANS, | | | DOES NOT INCLUDE ANY MECHANICAL A/C SYSTEMS WHICH ARE | | | SHOWN ON PLANS. | | | PLEASE SEE OTHER INFORMATION FOR ELECTRICAL SYSTEMS | | | WHICH ARE ON PLANS NOW ARE REMOVED FROM THE ENERGY | | | CALCULATIONS. | | | | | | | | | ** PLEASE SEE THE LIGHTING TIMES FOR MAXIMUM PERMITTED | | | OVER RIDES COULD HAVE BEEN REDLINED ON PLANS, HOWEVER | | | STATING THIS FACILITY CONTAINS "OPERATING ROOM" ON THE | | | ENERGY CALCULATIONS WHEN THIS DOES NOT HAVE THIS | | | OCCUPANCY AS A HOSPITAL. | | | | | | | | | ** PLEASE KNOW ONE COPY OF ENERGY CALCULATIONS | | | SUBMITTED AND PLANS ARE NOW BEING RETAINED BY THIS | | | OFFICE. | | | | | | | | | | | | 2) NOTE: PLEASE SEE PERMIT APPLICATION NOW CONTAINS A | | | PARCEL CONTROL NUMBER WHICH IS FOR THE ADDRESS OF 3230, | | | THIS WILL BE CHANGED BY THE ADDRESSING REVIEWER OR THIS | | | OFFICE BEFORE PERMIT ISSUANCE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-01-09 18:27:13 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-04 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-04 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2006-11-04 18:36:28 | *** UNSAT 4TH REVIEW*** | | | | | | | | | ** PLEASE KNOW THIS IS STILL UNDER "PLAN REVIEW" ONLY. | | | NO APPLICATION FOR PERMIT HAS YET BEEN MADE TO DATE. | | | PLEASE KNOW A CODE CHANGE FOR NFPA-70 IS COMING AND IF | | | PERMIT IS NOT APPLIED FOR BEFORE STATE ADOPTS NEW CODE, | | | THEN THE PLANS WILL BE REQUIRED TO CHANGE AS NEEDED. | | | THE TENTATIVE DATE IS DEC 1ST, 2006 | | | | | | 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS AND | | | ENERGY CALCULATIONS IN AND NEAT AND ORDERLY FASHION. | | | PLEASE SEE ONLY PARTS OF WHAT SEEMS TO BE A PARTIAL SET | | | OF REVISED ENERGY CALCULATIONS WERE SUBMITTED. PLEASE | | | SEE IN EITHER CASE THE PARTIAL ENERGY CALCULATIONS ARE | | | NOT SIGNED, DATED OR SEALED BY THE DESIGNER OF | | | RECORD??? THEY ARESIGNED AND DATED10/23/06, BUT NOT | | | SEALED AND NOT IN ANY ORDER OF ANY KIND?? | | | PLEASE SUBMIT AS REQUIRED AND REQUESTED. | | | FBC ADMINISTRATIVE SECTION AS ADOPTED BY THE CITY OF | | | WEST PALM BEACH 106.1.2, 106.1.3. , 106.3.5.1 ETC. | | | | | | | | | 2) NOTE: PLEASE SEE OUR SYSTEM STILL INDICATES PLANS | | | BEING REVIEWED UNDER THE ADDRESS OF 3222 COMMERCE PL, | | | THE "PLAN REVIEW" SUBMITTAL SHEET WHEN PLANS WERE | | | SUBMITTED ALSO INDICATE "3222" | | | PLEASE CORRELATE, AND ONCE AN ADDRESS IS FINALIZED, | | | PLEASE ADJUST PLANS AS NEEDED OR IF NEEDED. | | | | | | 3) NOTE: PLEASE SEE COMPLIANCE WITH FBC CHAPTER 13, | | | 13-415.1.ABC.1.1, .1.2 HAS NOT YET BEEN MET. PLEASE SEE | | | NEW OC SENSOR TYPE SWITCHES WERE ADDED TO SOME ROOMS | | | AND SOME AREAS INDICATE A NOTE #7 IN AN OCTAGONAL SHAPE | | | WHICH MENTIONS TO ADD AN OVER RIDE SWITCH, WITH A MAX | | | OF 1HR, HOWEVER PLEASE SEE THIS NOTE IS ADDED AT FRONT | | | DOOR, YET NO "S" IS SHOWN? PLEASE SEE OTHER AREAS WHICH | | | DO INDICATE AN OC, YET NO TIME LIMITS ARE INDICATED ON | | | SYMBOL LEGEND? | | | PLEASE SEE OTHER AREAS WHICH CONTAIN SWITCHES, BUT THEY | | | WERE NOT CHANGED??? | | | PLEASE SEE MAX TIMES PERMITTED ON OC SENSOR DEVICES AS | | | PERVIOUSLY NOTED PER SECTIONS GIVEN. (30MINS MAX ON OC | | | TYPE AND 4HR MAX ON TIMER TYPE) | | | PLEASE SEE NOTES #1 , AS ENERGU | | | CALCULATIONS/PERFORMANCE CALCUALTIONS SUBMITTED DO NOT | | | PROVIDE THE INFORMATION AS REQUIRED. PLEASE SEE | | | 13-415.2.ABC.1, TABLE(S) 415.2.C.1 | | | | | | 4) NOTE: PLEASE SEE A SIGN CIRCUIT HAS NOW BEEN ADDED, | | | YET PLEASE SEE 600.5, WHICH REFERENCES THE | | | 220.3(B)(6). PLEASE SEE THE MINIMUM VA SHALL BE | | | INDICATED. (SHOWN AS 600VA) | | | | | | | | | ** PLEASE KNOW, AS PLANS HAVE ONLY BEEN SUBMITTED FOR A | | | "PLAN REVIEW "SERVICE AND NOT FOR PERMIT, THIS DOES NOT | | | FALL UNDER THE SAME ENFORCEMENT AS REQUIRED FOR REPEAT | | | CODE COMPLAINT COMMENTS 3 OR MORE TIMES AS REQUIRED IN | | | FS 553.80(2)(B). | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-28 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-28 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | ***** UNSAT3RD REVIEW ****** | | | | | | ** PLANS STILL ONLY SUBMITTED FOR "PLAN | | | REVIEW> | | | | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES . | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW AND NEW | | | NOTES ARE ADDED AT THE BOTTOM. | | | | | | | | | | | | *** NEW NOTE *** | | | ** IMPORTANT*** | | | | | | 1)A)NOTE; PLEASE KNOW, TO WHOM IT MAY | | | CONCERN:. WHEN PLANS ARE SUBMITTED TO | | | THE CONSTRUCTION SERVICES DEPARTMENT, | | | THE "DATE STAMP" MAY NOT BE BORROWED | | | FROM ANY FRONT COUNTER PERSONEL AND USED | | | TO STAMP EACH PAGE OF SAID PLANS BEING | | | SUBMITTED. THIS DATE STAMP ON EACH SHEET | | | IS ONLY DONE WHEN PLANS ARE READY FOR | | | ISSUANCE AND THIS IS DONE BY THEPLAN | | | REVIEW STAFF ONLY. | | | | | | 1)B) NOTE: PLEASE SEE NONE OF THE | | | ARCHITECTURAL SHEETS ARE SIGNED, DATED | | | OR SEALED BY THE ARCHITECT OF RECORD. | | | PLEASE SEE FS 481.221 | | | THIS COMMENT IS REQUIRED WHETHER OR NOT | | | MADE BY OTHER REVIEWERS. | | | | | | 1)C) NOTE: PLEASE SEE ADDDRESS APPLIED | | | FOR"PLAN REVIEW" WAS UNDER "3222" AND | | | NOW ARE BEING SHOWN IN TITLE BLOCKS | | | UNDER THE ADDRESS OF "3230". PLEASE | | | KNOW, THE PAPERWORK HAS BEEN ROUTED TO | | | "ADRESSING" AND THE APPLIED FOR "PERMIT" | | | OR "PLAN REVIEW" WILL NEED TO CORRELATE | | | AND BE CORRECTED. | | | | | | ** PREVIUOUS REVIEW NOTES BELOW WHICH | | | ARE NOT ADDRESSED. | | | | | | | | | 1)NOTE: OK. | | | | | | 2)NOTE: OK. | | | | | | | | | 3)NOTE: OK. | | | | | | 4)NOTE: OK. | | | | | | 5)NOTE: NO, SAME NOTE, IF ONE IS NOT | | | EXISTING , ONE WILL BE REQUIRED. THE | | | CODE DOES NOT SAY AN ELECTRICAL SIGN | | | MUST BE INSTALLED, HOWEVER ELECTRIC AT A | | | J-BOX LOCATED AT THE FRONT ENTRANCE IS | | | REQUIRED. | | | 600.5. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #2** | | | NO, PLEASE SEE RESPONSE MENTIONS | | | TO VERIFY, HOWEVER THIS IS REQUIRED AT | | | THIS TIME TO EITHER SHOW NEW OR EXISTING | | | PER 600.5, 1500VA MIN. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #1** | | | PLEASE INDICATE EITHER NEW OR | | | EXISTING SIGN CIRCUIT PER 600.5 | | | | | | 6)NOTE:NO, WHERE IS LARGEST MOTOR | | | LOAD BEING SHOWN AT 125%. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #2** | | | NO, PLEASE SEE LOADS FOR ALL | | | EXISTING AND NEW LOADS SHALL BE SHOWN | | | FOR EXISTING AND NEW. | | | PLEASE SEE IT WAS NOT STATED WHETHER OR | | | LOADS ARE DONE AT 125% FOR CONTINUOUS | | | AND LOAD FOR LARGEST MOTOR LOADS. | | | PLEASE SEE PREVIOUS NOTE ABOVE WITH | | | RESPECT TO THE 4TH TENANT SERVICE WHICH | | | DOES NOT SEEM TO BE INCLUDED IN RISER | | | AND CALCULATIONS. | | | 215.3,230.42,220.3,220.10,220.11,220.13 | | | ,ETC | | | | | | ** PREVIOUS NOTE REVIEW #1 ** | | | PLEASE VERIFY ALL LOADS FOR | | | EXISTING WIREWAY. PLEASE INDICATE THESE | | | LOADS AND THE ADDED NEW LOADS. | | | 215.5,220 | | | PLEASE SEE IT APPEARS A CONTINUOUS LOAD | | | FACTOR OF 125% IS BEING DONE FOR | | | LIGHTING, HOWEVER UNABLE TO VERIFY AS | | | THIS IS NOT SHOWN? | | | 215.3,230.42 ETC. | | | | | | 7)NOTE: OK. | | | | | | 8)NOTE: NO, PLEASE SEE SAME NOTE, NO | | | CONTROLS SHOWN OR SUBMITTED. PLEASE SEE | | | RESPONSE ONLY MENTIONS, ENERGY | | | CALCULATIONS? | | | PLEASE ASLSO SEE ONLY ONE COPY OF THE | | | ENERGY CALCUALTIONS ARE SIGNED , DATED | | | AND SEALED WITH TEH RAISED SEAL AS | | | REQUIRED UNDER FS 471.025. ETC | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #2** | | | NO, PLEASE SEE COMPLIANCE FOR | | | THIS COULD NOT BE LOCATED. PLEASE SEE NO | | | LIGHTING CONTROLS, AUTOMATIC SHUTT OFF, | | | SCHEDULING ETC WAS SHOWN. PLEASE SEE | | | SEPARATE SPACES AND DEVICES REQUIRED FOR | | | OVER RIDES. PLEASE LSIT THE DEVICES | | | BEING CHOSEN AND THE TIME LIMITS AS SET | | | FORTH IN CHAPTER 13. | | | PLEASE SEE ENERGY CALCULATIONS SHALL BE | | | SIGNED, DATED AND SEALED. PLEASE SEE EN | | | CALCS CONTAIN A "RUBBER STAMP" WHICH IS | | | NOT PERMITTED UNDER FS 471.025 | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #1 ** | | | PLEASE SEE FBC 2004, CHAPTER 13 | | | FOR COMMERCIAL BLGS. | | | PLEASE SEE 13-413.1.ABC.1.1&.2 | | | PLEASE SEE 13-415.1.ABC.1.1 &.2&.3 | | | 13-415.1.ABC.3, 13-415.1.AB.1 | | | SCHEDULING, SPACE LAYOUT, DEVICE | | | LOCATIONS ETC WILL BE REQUIRED AT A MIN. | | | | | | **** NEW NOTES 2ND REVIEW ***** | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: OK. | | | | | | | | | | | | | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-07 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-06 |
Time |
20:45 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | ***** UNSAT ****** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES . | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW AND NEW | | | NOTES ARE ADDED AT THE BOTTOM. | | | | | | ** PLEASE STILL KNOW, PLANS ARE ONLY | | | BEING SUBMITTED FOR "PLAN REVIEW" AND | | | ARE BEING SUBMITTED FOR PERMIT. | | | | | | | | | | | | 1)NOTE: NO, PLEASE SEE AREAS OF PLANS | | | WHICH STILL INDICATE THE 2001 FBC. | | | PLEASE SEE ARCH WHICH NOW INDICATES THE | | | 2004 FBC, WHICH SHOULD BE THE 2002 | | | NFPA-70 | | | PLEASE SEE THE FOLLOWING CODES ARE | | | REQUIRED FOR THIS REVIEWER. OTHERS MAY | | | BE REQUIRED FOR OTHER TRADES. | | | 2004 FBC, 2002 NFPA-70 (NEC), 2002 | | | NFPA-72, 2003 LS, NFPA-101. AT A MIN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE KNOW, AS OF OCT 1ST,2005 THE | | | STATE OF FLORIDA ADOPTED THE 2004 FBC. | | | PLEASE SEE MANY LOCATIONS ON PLANS WHICH | | | INDICATE 2001 ETC. | | | PLEASE ADJUST. | | | | | | 2)NOTE: NO, PLEASE STILL SEE MISSING | | | CERTIFICATE OF AUTHORIZATION NUMBER | | | REQUIRED FOR ENGINEERING COMPANY. | | | OTHER ITEMS WERE OK. SEE NE NOTE FOR EN | | | CALCS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING INFORMATION | | | ON BOTH TITLE BLOCKS FOR ARCHITECT AND | | | ENGINEERING FIRM. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G1-16.004 FOR ARCHITECT'S, MISSING THE | | | PRINTED LICENSE # ON ALL TITLE BLOCKS | | | AND SHEETS. | | | PLEASE SEE FAC 61G15-23.002 FOR MISSING | | | INFORMATION ON ENGINEER'S TITLE BLOCK, | | | PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | FLORIDA STATUES 471.023 | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT(S) ARE MAADE BY OTHER | | | REVIEWER(S). | | | | | | 3)NOTE:OK/NO, PLEASE SEE LETTER WAS | | | SUBMITTED HOWEVER IT WAS SHOULD BE | | | SEALED WHEN DATED AND NOTORIZED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FS 471.025 WHICH | | | REQUIRES A LEGAL SIGNATURE FROM THE | | | ENGINEER. PLANS SEEM TO CONTAIN | | | "INITIALS"?, IF INDEED THIS IS THE | | | "LEGAL SIGNATURE" OF SAID ENGINEER , | | | PLEASE PROVIDE A SIGNED, DATED AND | | | SEALED LETTER FOR VERIFICATION OF LEGAL | | | SIGNATURE. PLEASE KNOW, LETTER SHOULD BE | | | PROPERLY NOTORIZED UNDER THE STATE | | | STATUES IN WHICH THE NOTORIZATION IS | | | TAKING PLACE. FS 117.05 | | | | | | 4)NOTE: NO, PLEASE SEE THE FOLLOWING AS | | | THERE ARE STILL DIFFERENCES IN PLANS, | | | RISER ETC. | | | A) PLEASE SEE RISER SHOWS 250MCM TO | | | PANEL "D" AND PANEL "D" SHOWS FEEDERS AS | | | 3/0'S? | | | PLEASE SEE FEEEDERS FOR PANEL "C" ARE | | | BEING SHOWN AS THE SAME ON 100A BRKR | | | FEED. PLEASE KNOW, THE 100A BRKR WILL NO | | | ACCEPT THE 3/0 CONDUCTORS. | | | PLEASE SEE RISER IS NOW SHOWING A THIRD | | | TENANT BUT STILL DOES NOT SEEM TO BE | | | COMPLETE. PLEASE SEE THAT THIS BUILDING | | | CONTAIN FOUR TENANTS. SEE COMMENT WITH | | | RESPECT TO LOADS. | | | PLEASE SEE CIRCUITING FOR AN EM LT IS | | | SHOWN TO A CIRCUIT 13, YET THIS SPACE IN | | | THE ELECTRICAL PANEL IS A "SPARE"?? | | | PLEASE SEE PLANS MENTIONS TO "RELOCATE" | | | THE EXISTING PANEL "C" , HOWEVER DOES | | | NOT SHOW THE NEW LOCATION. | | | PLEASE CORRELATE THESE AND PLEASE GO | | | OVER PLANS. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE CORRELATE ALL EQUIPMENT, | | | LOADS, SIZES ETC ON EQUIPMENT SCHEDULE | | | AND PANEL SCHEDULE/ LOAD CALCS. | | | PLEASE ADJUST PLANS AS NEEDED AS SOME DO | | | NOT MATCH. | | | 215.5 | | | | | | 5)NOTE: NO, PLEASE SEE RESPONSE MENTIONS | | | TO VERIFY, HOWEVER THIS IS REQUIRED AT | | | THIS TIME TO EITHER SHOW NEW OR EXISTING | | | PER 600.5, 1500VA MIN. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE INDICAET EITHER NEW OR | | | EXISTING SIGN CIRCUIT PER 600.5 | | | | | | 6)NOTE: NO, PLEASE SEE LOADS FOR ALL | | | EXISTING AND NEW LOADS SHALL BE SHOWN | | | FOR EXISTING AND NEW. | | | PLEASE SEE IT WAS NOT STATED WHETHER OR | | | LOADS ARE DONE AT 125% FOR CONTINUOUS | | | AND LOAD FOR LARGEST MOTOR LOADS. | | | PLEASE SEE PREVIOUS NOTE ABOVE WITH | | | RESPECT TO THE 4TH TENANT SERVICE WHICH | | | DOES NOT SEEM TO BE INCLUDED IN RISER | | | AND CALCULATIONS. | | | 215.3,230.42,220.3,220.10,220.11,220.13 | | | ,ETC | | | | | | ** PREVIOUS NOTE ** | | | PLEASE VERIFY ALL LOADS FOR | | | EXISTING WIREWAY. PLEASE INDICATE THESE | | | LOADS AND THE ADDED NEW LOADS. | | | 215.5,220 | | | PLEASE SEE IT APPEARS A CONTINUOUS LOAD | | | FACTOR OF 125% IS BEING DONE FOR | | | LIGHTING, HOWEVER UNABLE TO VERIFY AS | | | THIS IS NOT SHOWN? | | | 215.3,230.42 ETC. | | | | | | 7)NOTE: NO, PLEASE SEE SOME EM LTS NOT | | | TO LOCAL LTS. SEE PREVIOUS NOTE ABOVE | | | FOR CIRCUIT #13 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF EM/ | | | EXT LTS. | | | PLEASE SEE ONE NOTE ON PLANS MENTIONS TO | | | SEE PANEL SCHEDULE FOR CIRCUITING , ONE | | | NOTE MENTIONS TO CIRCUIT TO LOCAL | | | LIGHTING CIRCUIT. | | | PLEASE KNOW, 700.12E REQUIRES TE BRANCH | | | CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL | | | BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA | | | AND CONNECTED AHEAD OF ANY LOCAL | | | SWITCHES. | | | PLEASE ADJUST NOTES ON PLANS, PLEASE | | | SHOW AND ADJUST PLANS FOR CIRCUITING. | | | | | | 8)NOTE: NO, PLEASE SEE COMPLIANCE FOR | | | THIS COULD NOT BE LOCATED. PLEASE SEE NO | | | LIGHTING CONTROLS, AUTOMATIC SHUTT OFF, | | | SCHEDULING ETC WAS SHOWN. PLEASE SEE | | | SEPARATE SPACES AND DEVICES REQUIRED FOR | | | OVER RIDES. PLEASE LSIT THE DEVICES | | | BEING CHOSEN AND THE TIME LIMITS AS SET | | | FORTH IN CHAPTER 13. | | | PLEASE SEE ENERGY CALCULATIONS SHALL BE | | | SIGNED, DATED AND SEALED. PLEASE SEE EN | | | CALCS CONTAIN A "RUBBER STAMP" WHICH IS | | | NOT PERMITTED UNDER FS 471.025 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 2004, CHAPTER 13 | | | FOR COMMERCIAL BLGS. | | | PLEASE SEE 13-413.1.ABC.1.1&.2 | | | PLEASE SEE 13-415.1.ABC.1.1 &.2&.3 | | | 13-415.1.ABC.3, 13-415.1.AB.1 | | | SCHEDULING, SPACE LAYOUT, DEVICE | | | LOCATIONS ETC WILL BE REQUIRED AT A MIN. | | | | | | **** NEW NOTES ***** | | | | | | 9) NOTE: PLEASE CLARIFY IF THERE IS A | | | NER OR EXISTING ROOFTOP GFI RECEPT. | | | 210.63, 210.8 | | | | | | 10) NOTE: PLEASE SPECIFY ALL CIRCUITS ON | | | SCHEDULE TO THE AREA(S) AND RM IN WHICH | | | THEY ARE FEEDING. IE: BATH LTS, OFFICE | | | #3 RECEPTS , ETC. | | | PLEASE ALSO INCLUDE ALL CONDUCTOR SIZES | | | ON PANEL SCHEDULE AND CORRELATE WITH THE | | | OCP AS SHOWN. | | | 240.4,310.16,408.4. | | | | | | | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF OLD/VOIDED | | | SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-07-06 00:00:00 | NOTES TO FOLLOW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-28 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-28 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2006-02-28 00:00:00 | ************ UNSAT ********** | | | | | | ** PLEASE KNOW, PLANS HAVE ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW" AND HAVE NOT | | | BEEN SUBMITTED FOR PERMIT. | | | | | | | | | 1)NOTE: PLEASE KNOW, AS OF OCT 1ST,2005 | | | THE STATE OF FLORIDA ADOPTED THE 2004 | | | FBC. | | | PLEASE SEE MANY LOCATIONS ON PLANS WHICH | | | INDICATE 2001 ETC. | | | PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE SEE MISSING INFORMATION | | | ON BOTH TITLE BLOCKS FOR ARCHITECT AND | | | ENGINEERING FIRM. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G1-16.004 FOR ARCHITECT'S, MISSING THE | | | PRINTED LICENSE # ON ALL TITLE BLOCKS | | | AND SHEETS. | | | PLEASE SEE FAC 61G15-23.002 FOR MISSING | | | INFORMATION ON ENGINEER'S TITLE BLOCK, | | | PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | FLORIDA STATUES 471.023 | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT(S) ARE MAADE BY OTHER | | | REVIEWER(S). | | | | | | 3)NOTE: PLEASE SEE FS 471.025 WHICH | | | REQUIRES A LEGAL SIGNATURE FROM THE | | | ENGINEER. PLANS SEEM TO CONTAIN | | | "INITIALS"?, IF INDEED THIS IS THE | | | "LEGAL SIGNATURE" OF SAID ENGINEER , | | | PLEASE PROVIDE A SIGNED, DATED AND | | | SEALED LETTER FOR VERIFICATION OF LEGAL | | | SIGNATURE. PLEASE KNOW, LETTER SHOULD BE | | | PROPERLY NOTORIZED UNDER THE STATE | | | STATUES IN WHICH THE NOTORIZATION IS | | | TAKING PLACE. FS 117.05 | | | | | | 4)NOTE: PLEASE CORRELATE ALL EQUIPMENT, | | | LOADS, SIZES ETC ON EQUIPMENT SCHEDULE | | | AND PANEL SCHEDULE/ LOAD CALCS. | | | PLEASE ADJUST PLANS AS NEEDED AS SOME DO | | | NOT MATCH. | | | 215.5 | | | | | | 5)NOTE: PLEASE INDICAT EITHER NEW OR | | | EXISTING SIGN CIRCUIT PER 600.5 | | | | | | 6)NOTE: PLEASE VERIFY ALL LOADS FOR | | | EXISTING WIREWAY. PLEASE INDICATE THESE | | | LOADS AND THE ADDED NEW LOADS. | | | 215.5,220 | | | PLEASE SEE IT APPEARS A CONTINUOUS LOAD | | | FACTOR OF 125% IS BEING DONE FOR | | | LIGHTING, HOWEVER UNABLE TO VERIFY AS | | | THIS IS NOT SHOWN? | | | 215.3,230.42 ETC. | | | | | | 7)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | PLEASE SEE 700.12E FOR CIRCUITING OF EM/ | | | EXT LTS. | | | PLEASE SEE ONE NOTE ON PLANS MENTIONS TO | | | SEE PANEL SCHEDULE FOR CIRCUITING , ONE | | | NOTE MENTIONS TO CIRCUIT TO LOCAL | | | LIGHTING CIRCUIT. | | | PLEASE KNOW, 700.12E REQUIRES TE BRANCH | | | CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL | | | BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA | | | AND CONNECTED AHEAD OF ANY LOCAL | | | SWITCHES. | | | PLEASE ADJUST NOTES ON PLANS, PLEASE | | | SHOW AND ADJUST PLANS FOR CIRCUITING. | | | | | | 8)NOTE: PLEASE SEE FBC 2004, CHAPTER 13 | | | FOR COMMERCIAL BLGS. | | | PLEASE SEE 13-413.1.ABC.1.1&.2 | | | PLEASE SEE 13-415.1.ABC.1.1 &.2 | | | 13-415.1.ABC.3, 13-415.1.AB.1 | | | SCHEDULING, SPACE LAYOUT, DEVICE | | | LOCATIONS ETC WILL BE REQUIRED AT A MIN. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICLA | | | PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF OLD/VOIDED | | | SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-25 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-25 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2007-04-25 14:27:24 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A1.2 AND E2.1 (ROUTED BY LUIS MARTINEZ) | | | WERE STAMPED, INITIALED, AND DATED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2007-04-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-11 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-11 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2007-04-11 15:35:36 | *****APPROVED***** | | | | | | | | | | | | SHEETS A1.2 AND E2.1 WERE STAMPED, INITIALED, AND | | | DATED ON 02/14/07 BUT WERE "VOIDED" BY OTHER PLAN | | | REVIEWERS.THE NEW RESUBMITTED SHEETS WERE RESTAMPED | | | WITH THE CURRENT DATE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-14 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-14 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2007-02-14 17:08:46 | *****APPROVED***** | | | | | | | | | | | | ALL COMMENTS FROM PREVIOUS FIRE PLAN REVIEWS HAVE BEEN | | | ADDRESSED.SHEETS A1.2 AND E2.1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-11-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-11-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2006-11-22 14:06:11 | ***APPROVED*** | | | | | | 1) PLEASE NOTE THAT ADDRESS ON APPLICATION DOESN'T | | | CORRULATE WITH PLANS. PLEASE MAKE CORRECTION. | | | | | | 2) SHEET T1.1 INDICATES SPRINKLERED BUILDING. SEPARATE | | | SHOP DRAWINGS AND PERMIT REQUIRED FOR FIRE SPRINKLER | | | REMODEL. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-10-25 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-10-25 |
Time |
07:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-10 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-10 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-23 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-23 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | ******DENIED****** | | | **PLAN REVIEW ONLY** | | | | | | 1) PLEASE NOTE THAT FLORIDA FIRE | | | PREVENTION CODE, 2004 EDITION SHALL BE | | | REFERENCED. SHT T1.1. | | | | | | 2) DUCT SMOKE DETECTOR SHALL BE LOCATED | | | IN SUPPLY AIR SYSTEM, NOT RETURN DUCT. | | | SHT M1.0. | | | | | | 3) 2A-10B,C RATED FIRE EXTINGUISHERS TO | | | BE MOUNTED AND ACCESSIBLE NOT TO EXCEED | | | 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | 4) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-06 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-06 |
Time |
13:20 |
Sent To |
M |
|
| Notes |
| 2007-08-06 13:21:09 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
16:52 |
Sent To |
M |
|
| Notes |
| 2007-07-30 16:53:20 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-16 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-16 |
Time |
08:56 |
Sent To |
M |
|
| Notes |
| 2007-07-16 08:56:54 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-17 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-17 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2007-04-17 13:25:17 | TO "COMM" BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-13 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-13 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2007-03-13 09:57:06 | TO "COMM" BD#47 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
15:05 |
Sent To |
E |
|
| Notes |
| 2007-02-22 15:06:16 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2007-01-08 09:13:48 | TO "COMM" BD#3 | | 2006-12-17 13:20:16 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-03 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-03 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2006-11-03 11:15:42 | TO "COMM" BD#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-12 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2006-09-25 00:00:00 | TO "COMM' BD#44 | | 2006-09-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | TO "COMM" BD#17 | | 2006-06-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-19 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-01-23 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | TO "COMM" BD#23 | | 2006-02-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-14 |
Time |
13:53 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-14 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2007-08-14 13:54:09 | REVISION TO MECHANICAL PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-08 |
Time |
09:22 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-08-08 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2007-08-08 09:35:00 | ** MECHANICAL REVISION ** | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 7-31-07 MECHANICAL PLANS ON | | | FILE ARE SEALED BY AN ARCHITECT ("KERRY PICKETT") SO | | | ONLY THIS ARCHITECT CAN MAKE REVISIONS TO THEM. | | | REVISION SUBMITTED HAS BEEN SEALED BY GEORGE SARFATTY. | | | PLEASE CORRECT. | | | | | | 2)INFORMATION MISSING IN TITLE BLOCK FOR ARCHITECT | | | SEE FAC 61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. ("JOB ADDRESS" | | | SEE CITY WPB AMEND. 106.1.1). | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-31 |
Time |
08:25 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-31 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2007-07-31 09:00:13 | ** MECHANICAL REVISION DENIED ** | | | 1) MECHANICAL PLANS ON FILE ARE SEALED BY AN ARCHITECT | | | (KERRY PICKETT) SO ONLY THE ARCHITECT CAN MAKE | | | REVISIONS TO THEM. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-17 |
Time |
11:52 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-07-17 |
Time |
11:52 |
Sent To |
B |
|
| Notes |
| 2007-07-17 11:54:03 | REVISION TO PLANS PAGE A1.1, BUILDING REV. NOT MECH. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-02-09 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-02-09 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2007-02-09 09:41:31 | -------------PROVISO--------------- | | | | | | DUCT MOUNTED SMOKE DETECTORS ARE TO BE LOCATED IN | | | SUPPLY DUCT PER FBC,M 606.2.1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-08 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-08 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2007-02-08 08:54:30 | PLAN DENIED. | | | 1) PLEASE PROVIDE A DETAIL ON HOW TO ANCHOR AIR | | | CONDITIONING CURB TO ROOF, AND RTU' S TO CURB. | | | 2) PLEASE REFER TO SECTION 606.2.1 SUPPLY AIR SYSTEM. | | | 3) PLEASE REFER TO CECTION 601.4 BALANCED RETURN AIR. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-16 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-16 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-18 |
Time |
09:54 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-08-18 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2006-08-18 00:00:00 | *** DENIED *** | | | 1) SEE MECHANICAL PLAN PAGE M1.0 | | | BUILDING CODE NOTES #1 REFERS TO 2000 | | | INTERNATIONAL MECH. CODE. MECHANICAL | | | CODE IN USE IS 2004 FLORIDA BUILDING | | | CODE MECHANICAL, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-03-13 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-03-13 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | PLAN DENIED | | | 1) ROOM 110 MISSING SUPPLY DUCT SIZE | | | 2) ROOM 116 MISSING RETURN AIR DUCT SIZE | | | 3) ROOM 171 MISSING SUPPLY DUCT SIZE | | | 4) PLEASE PROVIDE BATHROOM EXHAUST ON | | | PLANS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-01 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-01 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-12-02 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-12-02 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2006-12-02 09:48:13 | RE-SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-11 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-11 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2006-10-11 17:12:02 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | 7. OK | | | | | | **************NEW COMMENT************** | | | | | | REFERENCE FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2004 CHAPTER 1 | | | | | | 1B. THE PERSONAL SEAL, SIGNATURE AND | | | DATE OF THE ARCHITECT SHALL APPEAR | | | ON ALL ARCHITECTURAL DOCUMENTS TO | | | BE FILED FOR PUBLIC RECORD. | | | FAC 61G1-16.003, FS 481.2055 AND | | | SECTION 106.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-05 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-05 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT T1.1 CODE INDICATED IS FBC-2001, | | | CODE ADOPTED IS FBC-2004. PLEASE CHANGE | | | REFERENCE TO PROPER CODE. | | | ****RESPONSE NOTED, BUT SOME REFERENCES | | | TO FBC-2001 STILL ON PLANS. | | | | | | 2. OK | | | | | | 3. SHT A1.2 DETAIL #4 BREAK ELEVATION: | | | SINK SHALL BE ACCESSIBLE. SUBMIT | | | INFORMATION SHOWING COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. | | | CLEAR FLOOR SPACE SHALL BE FORWARD | | | APPROACH AND NO CABINET DOORS ALLOWED IN | | | THE CLEAR FLOOR SPACE. | | | ****RESPONSE NOTED, BUT DETAIL SHOW | | | 120'-0" OPENING. PLEASE CLARIFY. - ALSO | | | SHOW THE FOLLING INFORMATION: | | | A. 11-4.24.3 KNEE CLEARANCE | | | B. 11-4.24.4 SINK DEPTH | | | C. 11-4.24.6 EXPOSED PIPES & SURFACES | | | D. 11-4.24.7 FAUCETS | | | | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | | | | 7. SUBMIT A WATER RISER DIAGRAM IN | | | ISOMETRIC FORM SHOWING ALL PIPE SIZES, | | | VALVES, WATER HAMMER ARRESTORS REQUIRED | | | BY SECTION 604.9. IF INSTALLED ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | | SECTION 106.3.5.1.3. | | | ****RESPONSE NOTED, BUT FULL OPEN VALVES | | | ARE REQUIRED AT THE TOP OF EVERY WATER | | | DOWN-FEED PIPE PER SECTION 606.1(4). | | | PLEASE SHOW ON RISER DIAGRAM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-17 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-03-16 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT T1.1 CODE INDICATED IS FBC-2001, | | | CODE ADOPTED IS FBC-2004. PLEASE CHANGE | | | REFERENCE TO PROPER CODE. | | | 2. SHT A DRINKING FOUNTAIN IS REQUIRED | | | PER TABLE 403.1. SHOW LOCATION ON THE | | | FLOOR PLAN. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH 11-4.15 AND ALL | | | SUBSECTIONS AS WELL AS 11-4.1.3(10)(A) | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY | | | BENDING OR STOOPING. | | | 3. SHT A1.2 DETAIL #4 BREAK ELEVATION: | | | SINK SHALL BE ACCESSIBLE. SUBMIT | | | INFORMATION SHOWING COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. | | | CLEAR FLOOR SPACE SHALL BE FORWARD | | | APPROACH AND NO CABINET DOORS ALLOWED IN | | | THE CLEAR FLOOR SPACE. | | | 4. SHT A1.3 DETAIL #3 SHOW THE | | | FOLLOWING: | | | A. FOR W/C'S | | | 11-4.16.3 HEIGHT | | | B. FOR LAVS | | | 11-4.19.2 HEIGHT & CLEARANCES | | | 11-4.19.4 EXPOSED PIPES AND SURFACES | | | 11-4.19.5 FAUCETS | | | 5. SHT A1.3 FIXTURE KEY D TO READ 19" | | | "MINIMUM" SECTION 11-4.19.6. | | | 6. P1.0 PLUMBING SPECIFICATION | | | (CONDENSATE DRAINAGE PIPING) 50/50 | | | SOLDER NOT APPROVED. SECTION 705.9.3. | | | SOLDER SHALL COMFORM TO ASTM B32. | | | 7. SHT P1.0 BUILDING CODE NOTES #15: AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | REFERENCE. SECTION 604.9. | | | 8. SHT P2.0 DWV DRAINAGE RISER DIAGRAM, | | | TRAPS SHOWN FOR WATER CLOSETS NOT | | | APPROVED. SECTION 1002.1(1). | | | 7. SUBMIT A WATER RISER DIAGRAM IN | | | ISOMETRIC FORM SHOWING ALL PIPE SIZES, | | | VALVES, WATER HAMMER ARRESTORS REQUIRED | | | BY SECTION 604.9. IF INSTALLED ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | | SECTION 106.3.5.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|