Plan Review Details - Permit 06010759
Plan Review Stops For Permit 06010759
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-01-24 Cont ID  
Sent By kconrad Date 2006-01-24 Time 12:31 Rev Time 0.30
Received By kconrad Date 2006-01-24 Time 12:31 Sent To I
Notes
2006-01-24 00:00:001)THE GAF STRATOVENT BASE SHEET IS
 REQUIRED TO BE MECHANICALLY ATTACHED DUE
 TO THE EXISTING ROOF CONDITIONS.THIS WAS
 DETERMINED AFTER THE PREINSPECTION OF
 THE SAME.THIS ENSURES THAT THE EXISTING
 ISOBOARD WILL BE PROPERLY ATTACHED AS
 PER THE RAS 117.
  
 2)THE EXISTING ROOFING BALLAST MUST BE
 STRIPPED AND THE EXISTING MEMBRANE
 CLEANED PRIOR TO THE RECOVER
 APPLICATIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-01-24 Cont ID  
Sent By amorse Date 2006-01-23 Time 09:45 Rev Time 0.00
Received By kconrad Date 2006-01-24 Time 12:07 Sent To  
Notes
2006-01-23 00:00:00 
  
 DENIED
  
 SENT TO KEN CONRAD FOR SITE INSPECTION