Plan Review Details - Permit 06010560
Plan Review Stops For Permit 06010560
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-26 Cont ID  
Sent By alange Date 2006-05-26 Time 09:32 Rev Time 1.00
Received By alange Date 2006-05-26 Time 09:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-15 Cont ID  
Sent By alange Date 2006-05-15 Time 09:09 Rev Time 0.66
Received By alange Date 2006-05-15 Time 09:09 Sent To  
Notes
2006-05-15 00:00:00DENIED
  
 4.ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVALS ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-02 Cont ID  
Sent By alange Date 2006-03-02 Time 09:06 Rev Time 2.50
Received By alange Date 2006-03-02 Time 07:33 Sent To  
Notes
2006-03-02 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.ENERGY CALCS SUBMITTED SHALL BE TO
 THE 2004 FBC.SIGN OWNER/AGENT ON
 CALCS.
  
 3.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR TILE ROOF, FLAT ROOF, OVER
 HEAD DOOR, TRANSOM WINDOW AND STRAPS AND
 TIE-DOWNS.
  
 4.PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMMENDMENT TO FBC 106.3.3
  
 6.SHOW BUCK DETAILS OFFERING FULL
 SUPPORT OF THE FRAME, (NO BEVELED BUCKS)
 PER FBC R-613.6.2
  
 7.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-04-25 Cont ID  
Sent By btrobaug Date 2007-04-25 Time 09:57 Rev Time 0.00
Received By btrobaug Date 2007-04-25 Time 09:38 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-01 Cont ID  
Sent By btrobaug Date 2006-05-01 Time 11:16 Rev Time 0.50
Received By btrobaug Date 2006-05-01 Time 10:27 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-27 Cont ID  
Sent By btrobaug Date 2006-01-27 Time 15:52 Rev Time 0.75
Received By btrobaug Date 2006-01-27 Time 12:47 Sent To P
Notes
2006-01-27 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE FIRMS CERTIFICATE OF
 AUTHORIZATION NUMBER IS REQUIRED IN THE
 TITLE BLOCK PER 61G1-16.004(2) FAC.
  
 2} THE LOAD CALCULATION INDICATES 196
 AMPS, THE "EXISTING METER/MAIN"
 INDICATES IT IS 200 AMP, NOTE #5 REFERS
 TO UPGRADING TO 150 AMPS. PLEASE
 CORRELATE, ALSO INDICATE THE SIZE OF THE
 GROUNDING ELECTRODE CONDUCTOR.
  
 3} THE NOTE REFERING TO AN EXTENDED
 "FEEDER" ON THE RISER DIAGRAM
 INDICATES THE SERVICE MAY BE MOVED, IF
 SO SHOW THE NEW LOCATION ON THE PLAN.
  
 AN ELECTRICAL PERMIT IS REQUIRED FOR
 THIS WORK. NO CONTRACTOR IS SIGNED ON
 THE APPLICATION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-12-29 Cont ID  
Sent By adarroug Date 2006-12-29 Time 11:44 Rev Time 0.00
Received By adarroug Date 2006-12-29 Time 11:44 Sent To M
Notes
2006-12-29 11:44:58TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-23 Cont ID  
Sent By adarroug Date 2006-05-23 Time 16:26 Rev Time 0.00
Received By adarroug Date 2006-05-23 Time 16:26 Sent To B
Notes
2006-05-23 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 10:36 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 10:36 Sent To E
Notes
2006-04-27 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-24 Cont ID  
Sent By adarroug Date 2006-01-24 Time 08:39 Rev Time 0.00
Received By adarroug Date 2006-01-24 Time 08:39 Sent To E
Notes
2006-01-24 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-02 Cont ID  
Sent By alange Date 2006-03-02 Time 09:33 Rev Time 0.00
Received By alange Date 2006-01-17 Time 17:31 Sent To  
Notes
2006-01-17 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-01-02 Cont ID  
Sent By pkrauss Date 2007-01-02 Time 11:11 Rev Time 0.00
Received By pkrauss Date 2007-01-02 Time 08:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-05-01 Cont ID  
Sent By tgordon Date 2006-05-01 Time 14:26 Rev Time 0.30
Received By tgordon Date 2006-05-01 Time 14:26 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-01-30 Cont ID  
Sent By tgordon Date 2006-01-30 Time 10:22 Rev Time 0.45
Received By tgordon Date 2006-01-30 Time 10:22 Sent To B
Notes
2006-01-30 00:00:00 
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004) PER FBC 13-600.3.A .
  
 2) ENERGY CAL'S. NEED TO BE SIGNED BY
 OWNER/AGENT.
  
 3)MASTER BATH EXHAUST FAN #2 IS NOT
 SHOWING ON MECHANICAL PLANS PLEASE
 CORRECT.
  
 4) ALL MASTER SUITE RETURN AIR GRILL
 SURFACE AREA'S ARE TO SMALL PLEASE
 CORRECT.
  
 5) AHU #2 RETURN AIR GRILL IN HALL 8X8
 SURFACE AREA IS TO SMALL.
  
 6) RETURN AIR GRILL IN LAUNDRY IS NOT
 SIZED.
  
 7) 8" RETURN AIR DUCT IN VEST. IS TO
 SMALL SEE NOTE #8.
  
 8) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 9) ARCHITECT'S LICENSE NUMBER MUST BE
 PRINTED ON PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-05-15 Cont ID  
Sent By jleech Date 2006-05-15 Time 07:11 Rev Time 0.00
Received By jleech Date 2006-05-15 Time 07:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-01-30 Cont ID  
Sent By jleech Date 2006-01-30 Time 08:08 Rev Time 0.50
Received By jleech Date 2006-01-30 Time 08:08 Sent To M
Notes
2006-01-30 00:00:00DENIED;
 1.SEE ELECTRICAL PLAN REVIEW'S NOT ONE.
 2.THE DRAIN FOR THE W/M IS REQUIRED TO
 BE 3" FBC-2004 PLUMBING SECTION 406.3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2006-01-23 Cont ID  
Sent By mmclean Date 2006-01-20 Time 16:49 Rev Time 0.00
Received By mmclean Date 2006-01-20 Time 16:49 Sent To I
Notes
***NONE***