Plan Review Details - Permit 06010522
Plan Review Stops For Permit 06010522
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-06-14 Cont ID  
Sent By jgomez Date 2006-06-14 Time 11:45 Rev Time 0.50
Received By jgomez Date 2006-06-14 Time 08:20 Sent To PC
Notes
2006-06-14 00:00:00REVISION. CHANGE FROM SHINGLES TO METAL
 ROOFING. NO NEED TO SENT TO HISTORIC
 BECAUSE ORIGINAL PERMIT APPLICATION
 STATED CHANGE OF SHINGLES TO METAL
 ROOFING AND IT WAS APPROVED BY HISTORIC.
 THEN, CONTRACTOR CHANGED BACK TO
 SHINGLES AND FINALLY CHANGED BACK AGAIN
 FOR METAL ROOFING.
 REVISED PERMIT UNDER "R". JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-01-19 Cont ID  
Sent By jgomez Date 2006-01-19 Time 11:29 Rev Time 0.50
Received By jgomez Date 2006-01-18 Time 18:10 Sent To PC
Notes
2006-01-19 00:00:001-19-06 WALKED APPLICATION TO HISTORIC
 TO REVIEW CHANGE BACK TO SHINGLES. THEY
 SIGNED OFF OK.
2006-01-18 00:00:00NEED TO PASS HISTORIC PRIOR TO PRINTING
 PERMIT. THERE WAS A CHANGE IN THE PERMIT
 APPLICATION. NOW INSTALLING 3 TAB
 SHINGLES INSTEAD OF METAL ROOFING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-17 Cont ID  
Sent By jgomez Date 2006-01-17 Time 16:44 Rev Time 0.50
Received By jgomez Date 2006-01-17 Time 16:44 Sent To PC
Notes
2006-01-17 00:00:00BUILDING REVIEW CHECKLIST:
 1- CERTIFIED BUILDING CONTRACTOR IS NOT
 ALLOWED TO DO METAL ROOFING. METAL
 ROOFINGTO BE DONE BY ROOFING
 CONTRACTOR ONLY. BUILDING AND GENERAL
 CONTRACTORS ARE LIMITED TO DO WOOD
 SHAKES, ASPHALT AND FIBERGLASS SHINGLES.
 SEE DBPR FOR CONTRACTOR'S LIMITATIONS.
  
 2- PROVIDE CALCULATIONS FOR INCREASED
 DESIGN PRESSURES AT PERIMETER AND CORNER
 AREAS AS REQUIRED BY 5-V CRIMP METAL
 ROOFING PANEL SYSTEM ON SYSTEM
 LIMITATION #1. SEE PAGE 5 OF 5 OF THE
 DADE COUNTY NOA SUBMITTED.
 ***CALCULATIONS TO BE SIGNED,SEALED AND
 DONE BY ENGINEER, ARCHITECT OR
 REGISTERED ROOF CONSULTANT.
  
 3- PROVIDE FLORIDA PRODUCT APPROVAL OR
 APPLY FOR LOCAL PRODUCT APPROVAL (AS
 REQUIRED BY RULE 9B-72 OF DCA) FOR METAL
 ROOF SYSTEM AND POLYSTICK UNDERLAYMENT
 TO BE USED. DADE COUNTY NOA ALONE IS NOT
 AUTOMATICALLY AND STATEWIDE FLORIDA
 PRODUCT APPROVAL.
  
 4- A) SPECIFY MEAN ROOF HEIGHT.
 B) SPECIFY ROOF PITCH.
 SEE CITY POLICY FOR RE-ROOF PERMITS. SEE
 ATTACHED COPY.
  
 5- CLEARLY IDENTIFY SPECIFIC POLYSTICK
 UNDERLAYMENT TO BE USED TO VERIFY
 COMPLIANCE WITH PRODUCT. SEE LIMITATIONS
 ON DADE COUNTY NOA SUBMITTED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-01-17 Cont ID  
Sent By jgomez Date 2006-01-17 Time 17:20 Rev Time 0.00
Received By jgomez Date 2006-01-17 Time 11:46 Sent To  
Notes
2006-01-17 00:00:00TO "JGOMEZ" DESK