Plan Review Details - Permit 06010488
Plan Review Stops For Permit 06010488
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-01-02 Cont ID  
Sent By shill Date 2007-01-02 Time 16:03 Rev Time 0.00
Received By shill Date 2007-01-02 Time 16:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-18 Cont ID  
Sent By shill Date 2006-10-18 Time 15:03 Rev Time 0.00
Received By shill Date 2006-10-18 Time 14:53 Sent To  
Notes
2006-10-18 15:45:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)SEE PREVIOUS LIST, INCORRECT ASCE REFERENCE FBC35.
 I FOUND IT IN TWO PLACES ON SHEET C BUT PLEASE CHECK
 ALL SHEETS.
  
 2.)IT APPEARS THAT WITH THE CHANGE OF SCOPE OF WORK,
 NO EXTERIOR COMPONENTS ARE BEING INSTALLED, SO WIND
 DESIGN CRITERIA PREVIOUSLY REQUESTED (INCLUDING ITEM 1)
 APPEARS UNNECESSARY.IF MY UNDERSTANDING IS CORRECT,
 YOU MAY REMOVE THE REFERENCE FROM THE PLAN IN LIEU OF
 CORRECTING IT.IF I AM NOT CORRECT, NOTE THAT PRODUCT
 APPROVALS REQUESTED PREVIOUSL.Y WERE NOT SUBMITTED AND
 INDICATE ON THE PLAN WHICH OPENINGS ARE BEING
 REPLACED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-05-25 Cont ID  
Sent By shill Date 2006-05-25 Time 12:22 Rev Time 0.00
Received By shill Date 2006-05-25 Time 12:21 Sent To  
Notes
2006-05-25 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 FROM PREVIOUS LIST:
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 7.)A SEPARATE PERMIT WILL BE REQUIRED
 FOR THE DUMPSTER ENCLOSURE FOR TRACKING
 PURPOSES.WHEN SUBMITTING A PERMIT
 APPLICATION, ALSO COMPLETE AN
 APPLICATION FOR THE DUMPSTER ENCLOSURE.
 SEPARATE PLANS ARE NOT REQUIRED.
  
 10.)PROVIDE WIND DESIGN INFORMATION
 FBC1603.1.4.
  
 SECOND REVIEW - THIS WAS PROVIDED BUT
 STATES THAT IT WAS DESIGNED TO ASCE7-98.
 THE CORRECT REFERENCE IS ASCE7-02,
 FBC35.
  
 11.)PRODUCT APPROVALS REQUIRED FOR
 COMPONENTS AND CLADDING.FLORIDA STATE
 OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9B72.
  
 SECOND REVIEW - THIS WAS NOT PROVIDED.
 PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD, FBC*106.3.3.
  
 12.)USE OF REMOVABLE SHUTTERS ON
 COMMERCIAL BUILDINGS MUST BE APPROVED BY
 THE BUILDING OFFICIAL.IF THIS IS YOUR
 INTENT, PLEASE CONTACT ME FOR THE
 PROCEDURE TO SUBMIT A MISSILE IMPACT
 PROTECTION INSTALLATION PLAN.
 RESUBMITTAL OF THE PLAN SHOWING
 REMOVABLE SHUTTERS WITHOUT ADDRESSING
 THIS ITEM WILL RESULT IN DELAYS IN
 PERMIT ISSUANCE.
  
 SECOND REVIEW - THE RESPONSE LETTER
 STATED THAT ALL GLAZING WILL BE IMPACT.
 NO PRODUCT APPROVALS WERE SUBMITTED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-18 Cont ID  
Sent By shill Date 2006-04-18 Time 17:58 Rev Time 0.00
Received By shill Date 2006-04-18 Time 17:58 Sent To  
Notes
2006-04-18 00:00:00****CORRECTIONS****
 ****PLAN CHECK ONLY****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)DOCUMENTS PREPARED BY AN ARCHITECT
 AND SUBMITTED FOR PUBLIC RECORD ARE TO
 BE SIGNED, SEALED, AND DATED ORIGINALS
 FAC61G1-16.003 (REDUCED SITE PLAN).
  
 3.)GOVERNING CODE IS FBC2004, FBC 2004
 EXISTING BUILDING CODE (NOT FBC2001)
 EFFECTIVE OCTOBER, 2005.
  
 4.)DECLARE CONSTRUCTION TYPE IN
 ACCORDANCE WITH FBC CHAPTER 3.
  
 5.)IT IS NOT CLEAR HOW YOU HAVE
 DETERMINED THE OCCUPANT LOAD.ASSEMBLY
 WITHOUT FIXED SEATS, UNCONCENTRATED, IS
 15 NET FBC TABLE 1004.1.2.WITHOUT
 ALLOWANCES FOR KITCHEN SPACE, WALLS,
 ETC. THE TOTAL BASED ON GROSS SQUARE
 FOOT AREA SHOULD BE 519.CLARIFY HOW
 YOU HAVE DETERMINED OCCUPANT LOAD.SEE
 FBC 1004.1.
  
 6.)PARKING IS TO COMPLY WITH CITY OF
 WEST PALM BEACH STANDARD.SEE ATTACHED
 AND SEE ZONING PROVISO ON THE PLAN.
  
 7.)A SEPARATE PERMIT WILL BE REQUIRED
 FOR THE DUMPSTER ENCLOSURE FOR TRACKING
 PURPOSES.WHEN SUBMITTING A PERMIT
 APPLICATION, ALSO COMPLETE AN
 APPLICATION FOR THE DUMPSTER ENCLOSURE.
 SEPARATE PLANS ARE NOT REQUIRED.
  
 8.)THIS COMMENT IS NOT REQUIRED TO BE
 ADDRESSED AS THE DOOR IS EXISTING.
 DOORS 3 LACK THE MANEUVERING CLEARANCE,
 PULL SIDE, FBC11-4.13.6, FBC11 FIGURE
 25.DINING 8 AND DINING 4.
  
 9.)DECLARE LEVEL OF ALTERATION, FBC EB
 3.
  
 10.)PROVIDE WIND DESIGN INFORMATION
 FBC1603.1.4.
  
 11.)PRODUCT APPROVALS REQUIRED FOR
 COMPONENTS AND CLADDING.FLORIDA STATE
 OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9B72.
  
 12.)USE OF REMOVABLE SHUTTERS ON
 COMMERCIAL BUILDINGS MUST BE APPROVED BY
 THE BUILDING OFFICIAL.IF THIS IS YOUR
 INTENT, PLEASE CONTACT ME FOR THE
 PROCEDURE TO SUBMIT A MISSILE IMPACT
 PROTECTION INSTALLATION PLAN.
 RESUBMITTAL OF THE PLAN SHOWING
 REMOVABLE SHUTTERS WITHOUT ADDRESSING
 THIS ITEM WILL RESULT IN DELAYS IN
 PERMIT ISSUANCE.
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-12-05 Cont ID  
Sent By dpalmer Date 2006-12-05 Time 19:06 Rev Time 0.00
Received By dpalmer Date 2006-12-05 Time 19:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-10-15 Cont ID  
Sent By dpalmer Date 2006-10-15 Time 16:23 Rev Time 0.00
Received By dpalmer Date 2006-10-15 Time 15:53 Sent To  
Notes
2006-10-15 16:23:28*** UNSAT ***
  
 2ND REVIEW UNDER PERMIT.
 3RD REVIEW DONE. FIRST REVIEW WAS UNDER "PLAN REVIEW
 ONLY".
  
 1) NOTE: PLEASE SEE NOTE FROM PREVIOUS REVIEW WITH
 RESPECT TO CIRCUITING OF EM /EXT LTS,
 700.12
  
 2) NOTE: PLEASE SEE NEW OCCUPANCY SENSORS NOW BEING
 SHOWN ARE NOT ON SYMBOL LEGEND AND NO MAX TIMES ARE
 SHOWN. PLEASE SEE MAX TIMES IF USING AN OCCUPANT SENSOR
 TYPE DEVICE.
 13-415.1.ABC.1.1, .1.2, .1.3
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-08 Cont ID  
Sent By dpalmer Date 2006-06-08 Time 17:55 Rev Time 0.00
Received By dpalmer Date 2006-06-08 Time 17:31 Sent To  
Notes
2006-06-08 00:00:00IN REVIEW
 ******** UNSAT ********
  
 ** PLANS SUBMITTED FOR PERMIT.
  
 1) NOTE: PLEASE SEE CIRCUITING FOR
 EM/EXT LTS SHALL BE CIRCUITED TO THE
 LOCAL BRANCH CIRCUIT LIGHTING IN ANY ONE
 AREA. PLEASE SEE A NOTE ON PLANS
 MENTIONS TO CIRCUIT TO LOCAL CIRCUIT
 AHEAD OF SWITCHING , HOWEVER PLEASE SEE
 THESE SEEM TO BE CIRCUITED TO DEDICATED
 CIRCUIT(S)?
 PLEASE KNOW, IF LIGHTING IN ANY ONE ARE
 GOES OUT BY SWITCHING OR TRIPPING A
 SINGLE MEANS OF OCP, THE EM LTS SHALL BE
 ACTIVATED. THIS WILL ALLEAVIATE ANY ONE
 AREA IN DARKNESS.
 700.12E,NFPA-101 7.9.2.2
  
 2) NOTE: PLEASE REFERENCE NFPA-101 2003,
 NFPA-72 2002 ON PLANS AS REQUESTED ON
 PREVIOUS REVIEW.
  
 3) NOTE: PLEASE PROVIDE LIGHTING
 CONTROLS PER FBC 13-415.1.ABC.1.1 AND
 13-415-.1.ABC.1.2 ETC.
 PLEASE PROVIDE SCHEDULING, DEVICES FOR
 OVERRIDES IN AREAS SO THAT THE LIGHTING
 CAN BE SEEN. PLEASE KNOW, NO MORE THAN
 4HRS IS PERMITTED FOR OVER RIDE DEVICES.
 A SPECIFIC SYSTEM SHALL BE SPECIFIED AND
 INDICATED ON PLANS.
 PLEASE SEE AREAS WITH SEPARATE SPACES.
  
 4) NOTE: PLEASE CLARIFY IF THE LOADS
 INDICATED ON PLANS ARE INDEED SHOWN AT
 125% ALREADY FOR CONTINUOUS LOADS, OR
 PLEASE SHOW THE CONTINUOUS LOADS.
 215.3,230.42
  
 5) NOTE: PLEASE BE SURE TO REMOVE OLD/
 VOIDED SHEETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 ** PLEASE SEE PLANS SUBMITTED ARE PLACED
 TOGETHER WITH ONLY ONE STAPLE AND SHOULD
 BE ATTACHED IN A MANNER SO THAT SHEETS
 DO NOT COME APART.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-02-13 Cont ID  
Sent By dpalmer Date 2006-02-13 Time 11:04 Rev Time 0.00
Received By dpalmer Date 2006-02-13 Time 07:09 Sent To  
Notes
2006-02-13 00:00:00IN ELEC FOR REVIEW.
 ********** UNSAT ********
  
  
 ** PLEASE KNOW: PLANS HAVE ONLY BEEN
 SUBMITTED FOR "PLAN REVIEW" ONLY AND NOT
 SUBMITTED FOR PERMIT.
  
  
 1)NOTE: PLEASE INCLUDE THE
 ARCHITECTUAL'S FIRM LICENSE NUMBER ON
 ALL TITLE BLOCKS FOR ALL SHEETS.
 FAC 61G1-16.004
 THIS IS REQUIRED FOR ALL TRADES AND
 REVIEWS WHETHER OR NOT COMMENT IS MADE
 BY OTHER REVIEWER(S)>
  
 2)NOTE: PLEASE SEE "C" SHEET CONTAINS
 REFERENCE TO THE 2001 FBC. PLEASE KNOW,
 AS OF OCT 1ST, 2005 THE STATE OF FLORIDA
 ADOPTED THE 2004 FBC.
  
 3)NOTE: PLEASE ALSO SEE THAT PLANS SHALL
 REFERENC CURRENT CODES IN EFFECT FOR THE
 NFPA-101 2003, NFPA-72 2002 AND NFPA-70
 2002 EDITIONS.
  
 4)NOTE: PLEASE INDICATE AND SHOW ALL
 CONTINUOUS LOADS AT 125%.
 215.3,230.42
  
 5)NOTE: PLEASE SEE FBC 2004, CHAPTER 13
 FOR ENERGY CODE CORRECTIONS.
 PLEASE SEE 13-101.13, 13-415.1.ABC.1.1,
 ETC
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2007-01-03 Cont ID  
Sent By mawillia Date 2007-01-03 Time 14:26 Rev Time 0.00
Received By mawillia Date 2007-01-03 Time 14:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2006-11-01 Cont ID  
Sent By mwennerg Date 2006-11-01 Time 15:47 Rev Time 0.00
Received By mwennerg Date 2006-11-01 Time 15:47 Sent To  
Notes
2006-11-01 15:50:29***DENIED***
  
 PLEASE SEE LAST FIRE REVIEW REGARDING OCCUPANT LOAD
 THAT HAS NOT BEEN ADDRESSES. PLANS STILL SHOW OCCUPANT
 LOAD OF GREATER THAN 300. A COPY OF THE LAST FIRE
 REVIEW IS ATTACHED FOR YOUR RESPONSE.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW (561) 805-6722 OR 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-06-16 Cont ID  
Sent By mwennerg Date 2006-06-16 Time 10:02 Rev Time 0.00
Received By mwennerg Date 2006-06-16 Time 10:02 Sent To  
Notes
2006-06-16 00:00:00***DENIED***
  
 THE RESUBMITTED PLANS NOW SHOW AN
 OCCUPANT LOAD OF 339. SHT C
 PLEASE SEE FIRST FIRE REVIEW COMMENT
 REGARDING OCCUPANT LOADS. IT WAS
 ORIGINALLY UNDERSTOOD THAT THE OCCUPANT
 LOAD WAS BELOW 300. PLEASE NOTE THAT
 FIRE ALARM SYSTEMS ARE REQUIRED IN
 ACCORDANCE WITH NFPA 101, 2003 EDITION
 WHERE OCCUPANT LOAD EXCEEDS 300.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-02-15 Cont ID  
Sent By mwennerg Date 2006-02-15 Time 10:38 Rev Time 0.00
Received By mwennerg Date 2006-02-15 Time 10:38 Sent To  
Notes
2006-02-15 00:00:00******DENIED******
  
 PLAN REVIEW ONLY
  
 1) IT WOULD APPEAR THAT BASED ON YOUR
 OCCUPANT LOAD CALCULATION, THIS BUILDING
 WILL NOT MEET THE REQUIREMENT FOR FIRE
 SPRINKLER AND FIRE ALARM SYSTEMS. AN
 OCCUPANT LOAD SIGN WILL BE REQUIRED AND
 MAY BE OBTAINED FROM THE BUREAU OF FIRE
 PREVENTION PRIOR TO AN OCCUPATIONAL
 LICENSE BEING ISSUED.
  
 2) PLEASE PROVIDE PRESCRIPTIVE STRENGTH
 REQUIREMENT FOR HANDRAILS AND GUARDS.
  
 3) PLEASE PROVIDE LIFE SAFETY SHEET TO
 ILLUSTRATE REQUIRED MEANS OF EGRESS AND
 MAX. TRAVEL DISTANCES.
  
 4) PLEASE PROVIDE MORE INFORMATION
 REGARDING FLAME RETARDANT/RESISTANCE OF
 AWNINGS.
  
 5) AN ADDRESS IS REQUIRED ON BUILDING,
 AND SHALL BE A MINIMUM OF 6" IN HEIGHT
 AND CONTRASTING TO BACKGROUND.
  
 6) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND CEILING,
 CLASS A,B OR C.
  
 7) 2A-10B,C RATED FIRE EXTINGUISHERS ARE
 REQUIRED AND SHALL BE MOUNTED NOT TO
 EXCEED 75' TRAVEL DISTANCE REQUIREMENT.
  
 8) LIFE SAFETY TO COMPLY WITH NFPA 101,
 2003 EDITION.
  
 9) WILL THE SCOPE OF WORK INCLUDE
 HOOD/SUPPRESSION SYSTEMS? SEPARATE SHOP
 DRAWINGS/PERMITS REQUIRED.
  
 10) CONSTRUCTION, ALTERATION AND
 DEMOLITION TO COMPLY WITH NFPA 241.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLANS REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-27 Cont ID  
Sent By adarroug Date 2006-11-27 Time 13:51 Rev Time 0.00
Received By adarroug Date 2006-11-27 Time 13:51 Sent To  
Notes
2006-12-05 14:48:38TO "COMM" BD#30
2006-11-27 13:52:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-27 Cont ID  
Sent By adarroug Date 2006-09-27 Time 14:28 Rev Time 0.00
Received By adarroug Date 2006-09-27 Time 14:28 Sent To  
Notes
2006-10-13 14:52:14TO "COMM BD#56
2006-09-27 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-31 Cont ID  
Sent By adarroug Date 2006-05-31 Time 09:58 Rev Time 0.00
Received By adarroug Date 2006-05-31 Time 09:58 Sent To Z
Notes
2006-05-31 00:00:00TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-02 Cont ID  
Sent By adarroug Date 2006-05-02 Time 16:26 Rev Time 0.00
Received By adarroug Date 2006-05-02 Time 16:26 Sent To  
Notes
2006-05-23 00:00:00TO "COMM" BD#55
2006-05-02 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-18 Cont ID  
Sent By shill Date 2006-04-18 Time 17:59 Rev Time 0.00
Received By shill Date 2006-01-17 Time 09:15 Sent To  
Notes
2006-02-01 00:00:00TO "COMM" BD#50
2006-01-17 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-01-11 Cont ID  
Sent By pkrauss Date 2007-01-11 Time 13:07 Rev Time 0.00
Received By pkrauss Date 2006-12-07 Time 07:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-02-24 Cont ID  
Sent By pkrauss Date 2006-02-24 Time 10:34 Rev Time 0.00
Received By pkrauss Date 2006-02-24 Time 10:25 Sent To  
Notes
2006-02-24 00:00:00*************PLAN CHECK ONLY************
 2004 FLORIDA BUILDING CODE
  
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.
  
 PLAN SHEET T.3 INDICATES NEW GRILLES TO
 BE INSTALLED TO EXISTING DUCTWORK.
  
 PLAN SHEET C, SCOPE OF WORK STATES HVAC,
 EXISTING KITCHEN TO REMAIN AS IS.
  
 PLAN REVIEW:PATTY KRAUSS
 MECHANICAL PLANS EXAMINER
 (561)805-6719
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-12-09 Cont ID  
Sent By pschmitz Date 2006-12-09 Time 12:08 Rev Time 0.00
Received By pschmitz Date 2006-12-09 Time 12:07 Sent To  
Notes
2006-12-09 12:10:28RE SUB
 NOTICE SENT TO LYNN MASSON, RE: GREASE TRAPS.

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-10-28 Cont ID  
Sent By pschmitz Date 2006-10-28 Time 10:51 Rev Time 0.00
Received By pschmitz Date 2006-10-28 Time 10:51 Sent To  
Notes
2006-10-28 10:59:47PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC 2004 FUEL GAS CODE PLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 UNSAT
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 NEW COMMENT SHT"C"SHEET INDEX LIST, P-1,P-2 ,SHT
 P-1 NOT INCLUDED FOR GREASE TRAP.
  
  
  
 PREVIOUS NOTE (2) DATED 3-11-06
 GREASE TRAP REMOVAL AND REPLACE.
 NOT ADDRESSED.
  
 CONTACT W P BEACHWATERPLANT LAB
 SUPERVISORINDUSTRIAL COORDINATOR,
 LYNN MASSON
 OFFICE 561-822-2271
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-06-24 Cont ID  
Sent By pschmitz Date 2006-06-24 Time 06:12 Rev Time 0.00
Received By pschmitz Date 2006-06-24 Time 06:12 Sent To  
Notes
2006-06-24 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC 2004 FUEL GAS CODE PLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 UNSAT
 PREVIOUS NOTE (2) DATED 3-11-06
 GREASE TRAP REMOVAL AND REPLACE.
 NOT ADDRESSED.
  
 CONTACT W P BEACHWATERPLANT LAB
 SUPERVISORINDUSTRIAL COORDINATOR,
 LYNN MASSON
 OFFICE 561-822-2271
 E-MAIL [email protected]
  
 END OF COMMENTS, QUESTIONS
 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-03-11 Cont ID  
Sent By pschmitz Date 2006-03-11 Time 12:07 Rev Time 0.00
Received By pschmitz Date 2006-03-11 Time 12:07 Sent To  
Notes
2006-03-11 00:00:00 
 PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 DENIED
 1) SHT CPROJECT DATA, CODE REFERENCE.
 PLANS REVIEWED AFTER NOV IST 2005
 FBC 2004
 2) SHT D-1 PARTIAL FLOOR PLAN NOTE 19
 RFERENCE TO FLR DRAIN, TO CATCH BASIN.
 NOT APPROVED.
 CONNECT DUMPESTER PAD DRAIN TO EXISTING
 GREASE TRAP.
 CONTACT W P BEACHWATERPLANT LAB
 SUPERVISORINDUSTRIAL COORDINATOR,
 LYNN MASSON
  
 OFFICE 561-822-2271
 E-MAIL [email protected]
 FOR CONDITION OF EXISTING GREASE TRAP.
 3) SHT T.1 DEMOLITION PLAN.
 DEMOLITION PERMIT REQUIRED BY LICENSED
 PLUMBING CONTRACTOR, FOR REMOVAL AND
 CAPPING OF ALL PLUMBING FIXTURES.
  
 END OF COMMENTS, QUESTIONS 561-805-6692
  
  

Review Stop Z ZONING
Rev No 4 Status P Date 2007-01-10 Cont ID  
Sent By mmclean Date 2007-01-10 Time 16:01 Rev Time 0.00
Received By mmclean Date 2007-01-10 Time 16:01 Sent To  
Notes
2007-01-10 17:20:15NOTE: PARKING MUST BE DOUBLE STRIPPED PER CITY CODE.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-10-24 Cont ID  
Sent By mmclean Date 2006-10-24 Time 18:10 Rev Time 0.00
Received By mmclean Date 2006-10-24 Time 18:10 Sent To  
Notes
2006-10-24 18:11:03NOTE: REVISION - PARKING MUST BE STRIPPED TO CITY CODE.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-05 Cont ID  
Sent By mmclean Date 2006-06-05 Time 14:23 Rev Time 0.00
Received By mmclean Date 2006-06-05 Time 14:23 Sent To  
Notes
2006-06-05 00:00:00RE-STAMP (NEW PLANS)

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-10 Cont ID  
Sent By mmclean Date 2006-04-10 Time 15:39 Rev Time 0.00
Received By mmclean Date 2006-04-10 Time 15:39 Sent To  
Notes
2006-04-10 00:00:00PROVISO: MUST PROVIDE TWO SETS OF
 LANDSCAPE PLANS SHOWING WHAT IS BEING
 REMOVED (DAMANGED BY HURRICANE) AND
 REPLACED - NEXT REVIEW.
  
 PROVISO: MUST HAVE 12" FOR HANDICAPP
 STRIPPED STALLS SEE BUBBLE. ALL PARKING
 MUST BE DOUBLE STRIPPED.