| Plan Review Stops For Permit 06010448 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-15 |
Time |
11:48 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-06-15 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | REVIEWED AND STAMPED AND ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-16 |
Time |
13:34 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-05-16 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | DENIED | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-30 |
Time |
13:53 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-03-30 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2006-03-30 00:00:00 | DENIED | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | 5.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | SHOW BUILDING CONSTRUCTION TYPE AND | | | CHANGE CODE SECTIONS TO REFLECT THE 2004 | | | FBC.SEE S-3 | | | | | | NEW COMMENT:BE SURE TO SEE NEW | | | ELECTRICAL NOTE #2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-13 |
Time |
09:55 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2006-02-13 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | DENIED | | | | | | 1.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUATION HAS BEEN REVISED TO | | | $142,651.00.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | 3.SUBMIT PRODUCT APPROVALS FOR LINTELS | | | AND STRAPS AND TIE-DOWNS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | ** PLEASE DO NOT ATTACH PRODUCT | | | APPROVALS TO PLANS** | | | | | | 4.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 5.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | SHOW BUILDING CONSTRUCTION TYPE AND | | | CHANGE CODE SECTIONS TO REFLECT THE 2004 | | | FBC. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-14 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-14 |
Time |
17:10 |
Sent To |
M |
|
| Notes |
| 2006-05-14 00:00:00 | PLANS REDLINED, | | | | | | SD'S ARE BEING SHOWN ON CIRCUIT A-2, IF | | | ON THIS CIRCUIT THEN AFCI PROTECTION | | | WILL BE REQUIRED.2002 210.12B | | | PANEL SCHEDULE DOES NOT INDICATE AFCI | | | PROTECTION FOR A-2 | | | ** THE SD'S SHOULD BE ON ONE OF THE | | | BEDRM CIRCUITS, MAY REVISE LATER. | | | PLANS STAMPED AND PASSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-17 |
Time |
19:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-17 |
Time |
19:38 |
Sent To |
M |
|
| Notes |
| 2006-03-17 00:00:00 | ******* UNSAT 2ND REVIEW ******** | | | | | | ** PLEASE SEE SOME NOTES FROM FIRST | | | REVIEW AND SOME NEW NOTES DUE TO PLANS | | | SUBMITTED. | | | NOTE BELOW ARE TAKEN DIRACTLY FROM FIRST | | | REVIEW NOTES. | | | | | | | | | 1)NOTE:NOTE #1 OK. | | | | | | | | | 2)NOTE: NOTE #2 OK. | | | | | | 3)NOTE:NOTE #3 OK, SEE NEW NOTES. | | | | | | 4)NOTE:NOTE #4 OK, HOWEVER SEE NEW | | | NOTE. | | | | | | | | | 5)NOTE: NOTE # 5 OK. HOWEVER SEE NEW | | | NOTE. | | | | | | 6)NOTE: NOTE #6 OK, HOWEVER SEE NEW | | | NOTE. | | | | | | NEW NOTES: | | | | | | 1)NOTE: PLEASE SEE SD'S ARE NOW BEING | | | SHOWN ON MORE THAN ONE CIRCUIT WHICH IS | | | NOT POSSIBLE SINCE ALL SD'S ARE REQUIRED | | | TO BE WIRED "INLINE" PER NFPA-72 | | | 11.5.1.1. PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE SEE ALL HAND DRAWN | | | CHANGES ON SIGNED, DATED AND SEALED | | | PLANS BY AN ENGINEER IS NOT PERMITTED | | | PER FS 471.025. PLEASE KNOW IT IS | | | PERMITTED FOR THE ENGINEER TO MAKE | | | CHNAGES, HOWEVER EACH INDIVIDUAL CHANGE | | | WOULD REQUIRE EACH AND EVERY ITEM TO BE | | | SIGNED, AND DATED. PLEASE KNOW, WITH AS | | | MANY CHANGES AS NOTED, THIS WOULD LEAVE | | | PLANS WITH THE GREAT POSSIBILITY OF WHAT | | | IS NEW OR OLD, CLEAR OR UNCLEAR ETC | | | PLEASE SEE FBC ADMINISTRATIVE SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH | | | 106.1.3 WHICH REQUIRES PLANS TO BE CLEAR | | | AND CONCISE, CLARITY ETC. PLEASE MAKE | | | ALL NEEDED PLANS IN COMPUTER, RE-PRINT | | | AND , SIGN, DATE AND SEAL PLANS. | | | | | | 3)NOTE: PLEASE COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONLY ONE COPY OF THE | | | REMOVED OLD/VOIDED SHEET S FOR | | | REFERENCE. | | | | | | | | | PLEASE SEE ANY OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE ON CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
22:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
22:51 |
Sent To |
M |
|
| Notes |
| 2006-01-20 00:00:00 | ******** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE MISSING FIRM LICENSE | | | NUMBER ON TITLE BLOCK FOR ARCHITECTUAL | | | FIRM. FAC 61G1-16.004, FS 481.219 | | | THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHETHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 2)NOTE: PLEASE SEEELECTRICAL PLANS ARE | | | SIGNED , DATED AND SEALED BY AN | | | ELECTRICAL ENGINEER, HOWEVER PLANS DO | | | NOT CONTAIN ANY TITLE BLOCK FOR SAID | | | ENGINEER OF RECORD AS REQUIRED PER FAC | | | 61G15-23.002, FS 471.023 | | | | | | 3)NOTE: PLEASE VERIFY THE 1/2" CONDUIT | | | SHOWN FOR FUTURE PHONE. IT IS KNOWN TO | | | THIS OFFICE THE TELEPHONE COMPANY AND | | | CABLE COMPANY REQUIRES A MIN OF 3/4" | | | CONDUIT FOR UNDERGROUND INSTALLATIONS. | | | THIS IS FOR INFORMATIONAL PURPOSE ONLY | | | AS THIS IS NOT AN NEC REQUIREMENT. | | | | | | 4)NOTE: PLEASE CORRELATE LOAD FOR RANGE | | | IN LOAD CALCS WITH LOAD ON PANEL | | | SCHEDULE. | | | PLEASE VERIFY IF INDEED A 40A BRKR WILL | | | BE USED AS MOST RANGES REQUIRE A MIN OF | | | 50A. (RANGE RECEPT IS 50A) | | | PLEASE ALSO VERIFY WIRING METHODS TO BE | | | USED. PLANS INDICATE CONDUIT AND WIRING, | | | HOWEVER IF ROMEX IS USED, THE #8 SHOWN | | | WOULD BE REQUIRED TO BE INCREASED TO #6. | | | SEE 310.16, 60 DEGREE COL. | | | 215.5 | | | | | | 5)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS IN THE PANEL | | | SCHEDULE PROVIDE. IT IS KNOWN THAT NOTE | | | #7 ON PLANS MENTIONS TO PROVIDE ARC | | | FAULT BRKRS FOR ALL BEDRMS, HOWEVER | | | PLEASE SEE 2002 NEC 210.12 WHICH | | | REQUIRES ALL "OUTLETS" IN BEDRMS TO BE | | | AFCI PROTECTED. THIS INCLUDES SD'S, | | | HOWEVER SD'S ARE SHOWN BEING WIRED TO | | | FAMILY RM RECEPTS. THIS IS OK, HOWEVER | | | THEN THIS CIRCUIT WOULD ALSO BE REQUIRED | | | TO BE ARC FAULT, THUS NOTE #7 WOULD NOT | | | REFERENCE. | | | | | | 6)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES LANSCAPE LTS, HOWEVER PLANS DO | | | NOT SHOW ANY. PLEASE KNOW, IF NONE SHOWN | | | ON PLANS, THEN LANDSCAPE LIGHTING WILL | | | BE REQUIRED TO BE UNDER A SEPARATE | | | PERMIT, WHICH WILL INCLUDE PERMIT, PLANS | | | AND FEE. | | | | | | ** PLEASE VERIFY WIRING METHOD, AS PLANS | | | INDICATE CONDUIT AND WIRING FOR ALL | | | CIRCUITS. IF SHOWN , ROMEX WOULD NOT BE | | | PERMITTED. | | | THIS IS ONLY A NOTE. | | | | | | PLEASE SEE ANY OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE ON CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-05 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-05 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2006-06-05 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-11 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-11 |
Time |
16:35 |
Sent To |
E |
|
| Notes |
| 2006-05-11 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
14:19 |
Sent To |
Z |
|
| Notes |
| 2006-05-04 00:00:00 | TO "Z" BOX/RESUB-NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-13 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-13 |
Time |
16:22 |
Sent To |
E |
|
| Notes |
| 2006-03-13 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-13 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-01-13 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-15 |
Time |
10:59 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-05-15 |
Time |
10:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-20 |
Time |
08:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-03-20 |
Time |
08:49 |
Sent To |
P |
|
| Notes |
| 2006-03-20 00:00:00 | *** DENIED ** | | | 1) ENERGY CALCULATIONS ARE CALLING FOR | | | 22,600 TOTAL BTU'S. MECHANICAL PLANS ARE | | | CALLING FOR 2 1/2 TON A/C SYSTEM | | | ESTIMATED 30,000 TOTAL BTU'S. THE PLANS | | | CAN NOT CALL FOR MORE BTU'S. THAN THAN | | | THE ENERGY CAL'S. | | | | | | 2) PLEASE SHOW THE TOTAL BTU'S. ON THE | | | MECHANICAL PLANS. | | | | | | 3) PLEASE SHOW THE COPPER LINE SIZES ON | | | THE MECHANICAL PLANS. | | | | | | 4) PLEAS SHOW THE LOCATION OF THE | | | CONDENSATE DRAIN LINE ON THE MECHANICAL | | | PLANS. | | | | | | 5) PLEASE SHOW THE LOCATION OF THE | | | CONDENSER UNIT ON THE MECH. PLANS. | | | | | | 6) PLEASE SHOW THE CLOTHES DRIER VENT | | | LOCATION ON THE MECH. PLANS. | | | | | | 7) PLEASE SHOW THE SIZE OF THE SUPPLY | | | AIR DUCT (FLEX) FROM THE AHU TO THE | | | MIXING BOX IN THE LIVING ROOM. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-25 |
Time |
11:43 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-01-25 |
Time |
11:43 |
Sent To |
B |
|
| Notes |
| 2006-01-25 00:00:00 | *** DENIED *** | | | 1)ENERGY CALCULATIONS NEED TO BE ON FORM | | | 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 2) NEED A/C CONTRACTOR'S LICENCE NUMBER, | | | NAME, AND SIGNATURE ON MECHANICAL PLANS. | | | ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 3)NEED JOB SITE ADDRESS ON MECHANICAL | | | PLANS. | | | | | | 4) SUPPLY AIR DUCTS FROM AHU TO MIXING | | | BOXES ARE NOT SIZED. | | | | | | 5) BEDROOM #1 RETURN AIR TRANSFER DUCT | | | IS TO SMALL,SEE NOTE #6. | | | | | | 6)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 7) MECHANICAL PLANS HAVE TO MUCH FLOOR | | | PLAN INFOMATION ON THEM AND ARE | | | DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY. PER 2004 FBC 106.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-16 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-16 |
Time |
07:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-29 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-29 |
Time |
14:18 |
Sent To |
B |
|
| Notes |
| 2006-03-29 00:00:00 | DENIED; | | | SEE ELECTRICAL PLAN REVIEW "NEW NOTES | | | #2". | | | I RED LINED THE PLUMBING DRAWINGS TO | | | HELP MAKE CORRECTIONS CLEAR. PLEASE MAKE | | | CHANGES AND PRINT OUT A NEW "P" PAGE | | | THANK YOU. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-23 |
Time |
12:51 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-23 |
Time |
12:51 |
Sent To |
M |
|
| Notes |
| 2006-01-23 00:00:00 | DENIED; | | | 1. SEE ELECTRICAL PLAN REVIEW COMMENT # | | | 1. | | | 2. WATER HAMMER ARRESTORS REQUIRED AT | | | KITCHEN SINK. | | | 3. HOUSE VALVE REQUIRED ON WATER SEVICE. | | | 4. W/M REQUIRES A 3" DRAIN PER 2004 | | | PLUMBING CODE | | | 5. CODE BOOKS USED FBC-2004. | | | 6. REMOVE NOTE 26 FROM PLUMBING | | | SPECIFICATIONS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-11 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-11 |
Time |
15:10 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-20 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-20 |
Time |
19:32 |
Sent To |
E |
|
| Notes |
| 2006-01-20 00:00:00 | NOTE: | | | 1.THE PORCH MUST SIT 25FT FROM THE FRONT | | | SETBACK. | | | 2.ROOF OVERHANG PROJECTIONS SHALL NOT | | | EXTEND FARTHER THAN THREE FEET INTO ANY | | | SETBACK. |
|
|