| Plan Review Stops For Permit 06010427 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-12 |
Time |
10:59 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-07-12 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-27 |
Time |
08:07 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-06-27 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | DENIED | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | | | | 4.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | NEW COMMENT: | | | A.713.13(2) F.S.THE NOTICE OF | | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | | THE DESCRIBED IMPROVEMENT OR | | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | | DAYS OF RECORDING. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-17 |
Time |
11:22 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-05-17 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | DENIED | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | | | | 4.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-13 |
Time |
11:22 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2006-02-13 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | DENIED | | | | | | 1.BASED ON ICC BUILDING VALUATION DATA | | | THE PERMIT VALUATION HAS BEEN REVISED TO | | | $145,578.00.ADDITIONAL PERMIT FEES ARE | | | DUE. | | | | | | 2.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | 3.SUBMIT PRODUCT APPROVALS FOR LINTELS | | | AND STRAPS AND TIE-DOWNS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | ** PLEASE DO NOT ATTACH PRODUCT | | | APPROVALS TO PLANS** | | | | | | 4.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 5.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | SHOW BUILDING CONSTRUCTION TYPE AND | | | CHANGE CODE SECTIONS TO REFLECT THE 2004 | | | FBC. | | | | | | 6.APPLICATION FOR PERMIT HAS NOT BEEN | | | COMPLETED BY A NOTARY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-21 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-21 |
Time |
19:34 |
Sent To |
B |
|
| Notes |
| 2006-06-16 00:00:00 | 6/16/06 CALLED CONTRACTOR, SPOKE TO | | | HAROLD DAVIDSON, RESUB WAS NOT PAID AND | | | PLANS ARE ON "HOLD" AND NOT BEING | | | PROCESSED UNTIL FES ARE PAID. PLANS ARE | | | UNDER "H", LARGE BINS. ONCE FEE IS PAID | | | PLEASE GIVE PLANS DIRECTLY TO DVP. DV | | | PALMER |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-14 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-14 |
Time |
17:35 |
Sent To |
M |
|
| Notes |
| 2006-05-14 00:00:00 | *** UNSAT 2ND REVIEW **** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES DUE TO CHANGES | | | MADE ON PLANS. | | | | | | PLEASE SEE NOTE BELOW MARKED WITH **, | | | ARE NOTES TAKEN DIRECTLY FROM PREVIOUS | | | REVIEW. | | | | | | ******** UNSAT ************ | | | | | | 1)NOTE: OK | | | | | | 2)NOTE: OK | | | | | | 3)NOTE: OK | | | | | | 4)NOTE: OK | | | | | | 5)NOTE: OK, SEE NEW NOTES FOR ARC FAULT. | | | | | | | | | NEW NOTE: | | | | | | 1) NOTE: PLEASEHOWEVER SEE SD'S ARE | | | NOW SHOWN WIRED TO LIV RM CIRCUIT, THIS | | | IS OK, HOWEVER THIS CIRCUIT WOULD NOW | | | REQUIRED AFCI PROTECTION. SD'S SHOULD BE | | | ON BEDRM CIRCUIT, BUT NOT REQUIRED TO. | | | PLEASE EITHER REVISE CIRCUIT NUMBER OR | | | PROVIDE ARC FAULT ON PANEL SCHEDULE NOW | | | FOR LIV RM. | | | | | | 2)NOTE: OK, HOWEVER PLEASE NOW SEE BATH | | | CIRCUITS ARE BEING NOTED AS ARC FAULT?? | | | THIS IS NOT REQUIRED , HOWEVER CAN BE | | | DONE AS AN ARC FAULT/GFI BRKR IS NOW | | | MADE. PLEASE CALL TO GO OVER THIS. | | | | | | 3) NOTE: PLEASE SEE FRONT AND REAR GFI | | | RECEPTS WERE REMOVED PER 210.52E ? | | | | | | 4) NOTE: PLEASE SEE MISSING KITCHEN | | | COUNTER SPACE RECEPT GFI PER 210.52C1, | | | 210.8A6 | | | | | | 5) NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 | | | | | | | | | | | | PLEASE SEE REDLINED PLANS FOR MISSING | | | RECEPTS PER 210.52 | | | ** PLEASE KNOW, IF PLANS PASS ALL OTHER | | | REIVEWSA "PROVISO" MAY BE SET UP FOR | | | THIS PLAN. | | | IF PLANS ARE DENIED FOR ANY OTHER | | | COMMENTS, PLEASE REVISE AT THIS TIME. | | | | | | PLEASE SEE ANY OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE ON CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
22:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
21:58 |
Sent To |
M |
|
| Notes |
| 2006-01-20 00:00:00 | ******** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE MISSING FIRM LICENSE | | | NUMBER ON TITLE BLOCK FOR ARCHITECTUAL | | | FIRM. FAC 61G1-16.004, FS 481.219 | | | THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHETHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 2)NOTE: PLEASE SEEELECTRICAL PLANS ARE | | | SIGNED , DATED AND SEALED BY AN | | | ELECTRICAL ENGINEER, HOWEVER PLANS DO | | | NOT CONTAIN ANY TITLE BLOCK FOR SAID | | | ENGINEER OF RECORD AS REQUIRED PER FAC | | | 61G15-23.002, FS 471.023 | | | | | | 3)NOTE: PLEASE VERIFY THE 1/2" CONDUIT | | | SHOWN FOR FUTURE PHONE. IT IS KNOWN TO | | | THIS OFFICE THE TELEPHONE COMPANY AND | | | CABLE COMPANY REQUIRES A MIN OF 3/4" | | | CONDUIT FOR UNDERGROUND INSTALLATIONS. | | | THIS IS FOR INFORMATIONAL PURPOSE ONLY | | | AS THIS IS NOT AN NEC REQUIREMENT. | | | | | | 4)NOTE: PLEASE CORRELATE LOAD FOR RANGE | | | IN LOAD CALCS WITH LOAD ON PANEL | | | SCHEDULE. | | | PLEASE VERIFY IF INDEED A 40A BRKR WILL | | | BE USED AS MOST RANGES REQUIRE A MIN OF | | | 50A. (RANGE RECEPT IS 50A) | | | PLEASE ALSO VERIFY WIRING METHODS TO BE | | | USED. PLANS INDICATE CONDUIT AND WIRING, | | | HOWEVER IF ROMEX IS USED, THE #8 SHOWN | | | WOULD BE REQUIRED TO BE INCREASED TO #6. | | | SEE 310.16, 60 DEGREE COL. | | | 215.5 | | | | | | 5)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS IN THE PANEL | | | SCHEDULE PROVIDE. IT IS KNOWN THAT NOTE | | | #7 ON PLANS MENTIONS TO PROVIDE ARC | | | FAULT BRKRS FOR ALL BEDRMS, HOWEVER | | | PLEASE SEE 2002 NEC 210.12 WHICH | | | REQUIRES ALL "OUTLETS" IN BEDRMS TO BE | | | AFCI PROTECTED. THIS INCLUDES SD'S, | | | HOWEVER SD'S ARE SHOWN BEING WIRED TO | | | MORE THAN ONE CIRCUIT. PLEASE ALSO SEE | | | SOME SD'S NOT CIRCUITED AT ALL. | | | | | | 6)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES LANSCAPE LTS, HOWEVER PLANS DO | | | NOT SHOW ANY. PLEASE KNOW, IF NONE SHOWN | | | ON PLANS, THEN LANDSCAPE LIGHTING WILL | | | BE REQUIRED TO BE UNDER A SEPARATE | | | PERMIT, WHICH WILL INCLUDE PERMIT, PLANS | | | AND FEE. | | | | | | ** PLEASE VERIFY WIRING METHOD, AS PLANS | | | INDICATE CONDUIT AND WIRING FOR ALL | | | CIRCUITS. IF SHOWN , ROMEX WOULD NOT BE | | | PERMITTED. | | | THIS IS ONLY A NOTE. | | | | | | PLEASE SEE ANY OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE ON CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-29 |
Time |
14:39 |
Sent To |
B |
|
| Notes |
| 2006-06-29 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
| 2006-06-15 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-11 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-11 |
Time |
16:38 |
Sent To |
E |
|
| Notes |
| 2006-05-11 00:00:00 | TO "DPALMER' DESK/RESU |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
14:50 |
Sent To |
Z |
|
| Notes |
| 2006-05-04 00:00:00 | TO "Z" BOX/RESUB--NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-13 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-01-13 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-15 |
Time |
09:30 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-15 |
Time |
09:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-25 |
Time |
11:34 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-25 |
Time |
11:34 |
Sent To |
B |
|
| Notes |
| 2006-01-25 00:00:00 | *** DENIED *** | | | 1)ENERGY CALCULATIONS NEED TO BE ON FORM | | | 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 2) NEED A/C CONTRACTOR'S LICENCE NUMBER, | | | NAME, AND SIGNATURE ON MECHANICAL PLANS. | | | ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 3)NEED JOB SITE ADDRESS ON MECHANICAL | | | PLANS. | | | | | | 4) SUPPLY AIR DUCTS FROM AHU TO MIXING | | | BOXES ARE NOT SIZED. | | | | | | 5) RETURN AIR TRANSFER DUCT FROM BEDROOM | | | #1 TO BEDROOM #2 IS NOT SIZED. | | | | | | 7) MECHANICAL PLANS HAVE TO MUCH FLOOR | | | PLAN INFOMATION ON THEM AND ARE | | | DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY. PER 2004 FBC 106.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-16 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-16 |
Time |
13:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-23 |
Time |
12:36 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-23 |
Time |
12:36 |
Sent To |
M |
|
| Notes |
| 2006-01-23 00:00:00 | DENIED; | | | 1.SEE ELECTRICAL PLAN REVIEW NOTE #1 | | | LIC# MISSING FROM TITAL BLOCK. | | | 2.WATER HAMMER ARRESTORS REQUIRED AT | | | KITCHEN SINK. | | | 3.AUTOMATIC CLOTHES WASHER DRAIN | | | REQUIRED TO BE 3". | | | 4. CODE BOOK TO BE USED IS THE FBC-2004, | | | NOT 2001. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-11 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-11 |
Time |
15:16 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-20 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-20 |
Time |
19:33 |
Sent To |
E |
|
| Notes |
|
|