| Plan Review Stops For Permit 06010356 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-03-06 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-03-06 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | DENIED | | | | | | NEEDS TO SUBMIT A RECORDED COPY OF THE | | | NOTICE OF COMMENCEMENT BEFORE PERMIT IS | | | ISSUED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-02-06 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-02-06 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2006-02-06 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PLANS DO NOT HAVE THE EMBOSSED SEAL | | | OF THE ENGINEER AS REQUIRED BY FS 471. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-01-13 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-01-13 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | DENIED | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) TWO EXISTS ARE REQUIRED FROM | | | MERCANTILE SPACE 129 PER 2004 FBC TABLE | | | 1018.2. BASED ON SCALED DIMENSIONS, AS | | | NONE ARE SPECIFIED ON PLANS. | | | | | | 3) CLARIFY THE DRY STORAGE/ MERCANTILE | | | AREA BETWEEN UNITS 128 AND 129. IS THERE | | | AN OPENING IN THE EXISTING WALL TO THE | | | EXISTING KITCHEN? | | | | | | 4) SHOW THE OPENINGS AT RESTROOMS AND | | | COOLER. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-03-07 |
Time |
12:39 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-03-07 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2006-03-07 00:00:00 | SHOW HOW ELECTRIC IS SEPARATED 128,129? | | | | | | YOU ARE PUTTING UP A WALL IN THE MIDDLE | | | OF A TENANT SPACE PLEASE SHOW HOW | | | ELECTRIC WAS SEPARATED.WIRING FROM | | | TENANT SPACE TO TENANT SPACE CAN NOT BE | | | MIXED????? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-04 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-04 |
Time |
13:21 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-02-04 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2006-02-04 00:00:00 | SEE NOTES FROM FIRST REVIEW | | | | | | SPACE IS BEING DIVIDED SHOW HOW ELECTRIC | | | WILL BE DIVIDED | | | | | | SHOW PANEL LOCATION | | | | | | SHOW METER LOCATION | | | | | | SHOW PANEL SCHEDULE FOR EACH SPACE AND A | | | LOAD CALCULATION FOR EACH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-01-18 |
Time |
22:13 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2006-01-18 |
Time |
22:12 |
Sent To |
FIRE |
|
| Notes |
| 2006-01-18 00:00:00 | PLEASE SHOW HOW ELECTRIC IS SEPARATED | | | THIS WAS ONE SPACE SO THE ELECTRIC HAS | | | TO BE DIVIDED. | | | | | | SHOW ALL WORK. | | | | | | | | | JAKE LEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-03-06 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-03-06 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-02-07 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-02-07 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | ******PROVISO****** | | | | | | PLEASE SEE OTHER REVIEW COMMENTS. PLANS | | | WILL BE STAMPED WHEN RESUBMITTED PENDING | | | COMPLIANCE WITH OTHER COMMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-19 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-19 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2006-01-19 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SHOW THE LOCATIONS OF EXIT | | | LIGHTS AND EMERGENCY LIGHTING. (NEW OR | | | EISTING) | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHERS | | | REQUIRED AND SHALL MMET THE REQUIREMENT | | | FOR 75' TRAVEL DISTANCE. | | | | | | 3) PLEASE INDICATE IF THESE SPACES ARE | | | PROTECTED BY FIRE SPRINKLER AND OR FIRE | | | ALARM SYSTEMS. IF SO, WILL THIS WORK | | | IMPACT ANY REQUIRED EQUIPMENT? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-03 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-03 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-03 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-03 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2006-02-03 00:00:00 | TO "BOB"#11 |
|
|