| Plan Review Stops For Permit 06010350 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-01-12 |
Time |
13:19 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-01-12 |
Time |
13:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-01-10 |
Time |
15:48 |
Rev Time |
0.75 |
| Received By |
jgomez |
Date |
2006-01-10 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2006-01-10 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- PROVIDE FLORIDA PRODUCT APPROVAL OR | | | APPLY FOR LOCAL PRODUCT APPROVAL FOR | | | FLAT ROOF SYSTEM AS REQUIRED BY RULE | | | 9B-72. DADE COUNTY NOA ALONE IS NOT | | | AUTOMATICALLY AN STATEWIDE FLORIDA | | | PRODUCT APPROVAL. | | | | | | 2- FLAT ROOF SYSTEM: FLAT ROOF SYSTEM ON | | | PAGE 20 OF DADE COUNTY NOA IS LIMITED BY | | | LIMITATION #7. NEED CALCULATIONS TO | | | ENHANCE UPLIFT LOAD AT PERIMETER AND | | | CORNERS. SEE LIMITATION #7 ON LAST PAGE | | | OF NOA. CALCULATIONS PER RAS 117. | | | | | | 3- PROVIDE 2 COPIES OF COMPLETE FLORIDA | | | PRODUCT APPROVAL. ONLY ONE NOA | | | SUBMITTED. | | | | | | 4- OWES $240.38 FOR LOW VALUATION | | | DECLARED ON THE PERMIT APPLICATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
|