| Plan Review Stops For Permit 06010329 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-30 |
Time |
15:44 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-03-30 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-07 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-13 |
Time |
10:25 |
Sent To |
PC |
|
| Notes |
| 2006-06-13 00:00:00 | REVIEW ON HOLD, PLANS OUTFRONT UNDER"L" | | | WAITING FOR INFORMATION TO BE SUBMITTED. | | | CONTRACTOR KNOWS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-09 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-09 |
Time |
19:31 |
Sent To |
P |
|
| Notes |
| 2006-05-09 00:00:00 | *** UNSAT ** 2ND REVIEW ** | | | | | | ** PLEASE SEE NOTE FROM PREVIOUS REVIEW. | | | | | | | | | 1)NOTE: OK, RE-SEALED SHEETS. | | | | | | 2)NOTE:NOTE #2 NO, NOTHING SUBMITTED. | | | PLEASE SEE THE "JOBSITE" ELECTRICAL PLAN | | | WAS VERIFIED, BUT NEED ELECTRICAL FOR | | | VAK PAK PANEL. CIRCUITS, LOADS, AWG, OCP | | | ETC. | | | ** PREVIOUS NOTE ** | | | PLEASE SUBMIT ELECTRICAL WIRING | | | DIAGRAM FOR ALL POOL EQUIPMENT AND | | | WIRING. | | | PLEASE PROVIDE GROUNDING DETAIL PER 680. | | | PLEASE SHOW HOW EQUIPMENT IS BEING FED, | | | FROM WHERE, SIZE, OCP, FEEDERS, BRANCH | | | CIRCUITS ETC ETC. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | PLANS ROUTED TO PLUMB FOR OTHER PERMIT # | | | 06010328. PLANS KEPT TOGETHER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-16 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-16 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | ********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.001 WHICH | | | REQUIRED THE RAISED SEAL TO CHANGE FROM | | | THE WORDING OF "CERTIFICATE" TO | | | "LICENSE" BY 2/5/04, HOWEVER AN | | | EXTENSION WAS GRANTED BY THE FLORIDA | | | BOARD OF PROFESSIONAL ENGINEERS TO | | | DECEMBER 31,2005. | | | PLEASE KNOW SEAL SHALL CONTAIN THE ABOVE | | | WORDING ON RAISED SEAL AS REQUIRED. | | | FS 471.025 | | | ANY STAMPED PLANS SHALL BECOME "VOID". | | | | | | 2)NOTE: PLEASE SUBMIT ELECTRICAL WIRING | | | DIAGRAM FOR ALL POOL EQUIPMENT AND | | | WIRING. | | | PLEASE PROVIDE GROUNDING DETAIL PER 680. | | | PLEASE SHOW HOW EQUIPMENT IS BEING FED, | | | FROM WHERE, SIZE, OCP, FEEDERS, BRANCH | | | CIRCUITS ETC ETC. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-17 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-03-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-07 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-07 |
Time |
18:05 |
Sent To |
E |
|
| Notes |
| 2006-06-07 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-03 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-03 |
Time |
10:16 |
Sent To |
E |
|
| Notes |
| 2006-05-03 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-30 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-01-11 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2006-01-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-03-17 |
Time |
13:05 |
Rev Time |
2.00 |
| Received By |
mperson |
Date |
2006-03-17 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2006-03-17 00:00:00 | | | | ******PROVISO****** | | | YARD DRAIN NOT AN APPROVED TYPE RECEPTOR | | | AND FILTER WASTE SHALL DISCHARGE INTO | | | THE SANITARY SYSTEM. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2006-02-13 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-02-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|