Plan Review Details - Permit 06010172
| Plan Review Stops For Permit 06010172 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-01-27 |
Time |
10:57 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-01-27 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
| 2006-01-27 00:00:00 | NOTE: GAS TO GENERATOR DELETED ON | | | RESUBMITTAL |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-01-18 |
Time |
13:38 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2006-01-18 |
Time |
13:38 |
Sent To |
PC |
|
| Notes |
| 2006-01-18 00:00:00 | DENIED | | | | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS. THE DRAWING SUBMITTED IS NOT | | | AN ISOMETRIC AND HARD TO READ. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | NEED SUBMITTAL ON 2# GAS REGULATERS, | | | NOTE: POOL HEATER PASSED WITH POOL | | | PERMIT. | | | 4. GAS PERMIT CAN'T BE ISSUED UNTIL | | | GENERATOR PERMIT IS APPROVED BY ZONING. | | | GENERATOR PLACEMENT APPROVAL BY ZONING | | | MIGHT REQUIRE MORE GAS PIPE. CHECK WITH | | | ELECTRICAL CONTRACTOR, OR OWNER ON THIS. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
14:02 |
Sent To |
G |
|
| Notes |
| 2006-01-23 00:00:00 | TO "G" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-01-27 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-01-06 |
Time |
11:37 |
Sent To |
PC |
|
| Notes |
| 2006-01-06 00:00:00 | TO "G" BOX |
|
|
|