| Plan Review Stops For Permit 06010091 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
N |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-12 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-12 |
Time |
09:09 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-11 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-11 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-04-03 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-04-03 |
Time |
19:55 |
Sent To |
|
|
| Notes |
| 2007-04-03 19:56:45 | STRUCTURAL SUBMITTAL ON 3/14/07 FOR STRUCTURAL | | | ENGINEER'S CALCULATIONS AND REINFORCING DETAILS AND | | | SPEC FOR 7TH FLOOR BEAMS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-01-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-01-27 |
Time |
06:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-01-27 |
Time |
05:34 |
Sent To |
PC |
|
| Notes |
| 2007-01-27 09:52:52 | PROVISOR: | | | | | | THESHIELDING SPECIFICATIONS REPORTS SHALL BE | | | ORIGINALY SIGNED BY THE PERSON WHO IS RESPONSIBLE. | | | THESE REPORTS SHALL THEN BE APPROVED BY THE ARCHITECT | | | OR ENGINEER OF RECORD WITH THEIR SEAL AND SIGNATURE. | | | EACH SHEET SHALL BE SIGNED OR A COVER SHEET REFERENCING | | | EACH SHEET SHALL BE PROVIDED WITH THE RREPORT. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-03 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | DENIED | | | | | | 1.BUILDING REVIEW OK. | | | | | | 2.SEE ELECTRICAL REVIEW NOTE #2. | | | THESE ITEMS ARE REQUIRED ON THE PLANS | | | PRIOR TO PERMITTING. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-07 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-07 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | DENIED | | | | | | 1.BUILDING REVIEW OK.SEE THE | | | FOLLOWING INFORMATION REQUIRED ON PLANS | | | FOR REVIEW. | | | | | | 2.2004 FBC 106.1 | | | IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT OR ENGINEER LEGALLY REGISTERED | | | UNDER THE LAWS OF THIS STATE REGULATING | | | THE PRACTICE OF ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, | | | PART I, OR ENGINEERING AS PROVIDED FOR | | | IN CHAPTER 471, FLORIDA STATUTES, THEN | | | HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA, AS | | | REQUIRED BY FLORIDA STATUTE. IF THE | | | DESIGN PROFESSIONAL IS A LANDSCAPE | | | ARCHITECT REGISTERED UNDER THE LAWS OF | | | THIS STATE REGULATING THE PRACTICE OF | | | LANDSCAPE ARCHITECTURE AS PROVIDED FOR | | | IN CHAPTER 481, FLORIDA STATUTES, PART | | | II, THEN HE OR SHE SHALL AFFIX HIS OR | | | HER SEAL TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA AS | | | DEFINED IN SECTION | | | 481.303(6)(A)(B)(C)(D), FS. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-06 |
Time |
15:40 |
Rev Time |
6.00 |
| Received By |
alange |
Date |
2006-04-06 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.ROOM 123 LEAD LINED WALLL NOT SHOWN | | | CONTINUOS BEHIND BATHRROM 126. | | | FBC 435.5.1.1 | | | STRUCTURAL SHIELDING IN WALLS AND OTHER | | | VERTICAL BARRIERS REQUIRED FOR PERSONNEL | | | PROTECTION SHALL EXTEND WITHOUT BREACH | | | FROM THE FLOOR TO A HEIGHT OF AT LEAST 7 | | | FEET. | | | | | | 3.DOOR FOR ROOM 118 NOT THE SMAE | | | RATING AS THE WALL. | | | FBC 435.5.1.2 | | | DOORS, DOOR FRAMES, WINDOWS AND WINDOW | | | FRAMES SHALL HAVE THE SAME LEAD | | | EQUIVALENT SHIELDING AS THAT REQUIRED IN | | | THE WALL OR OTHER BARRIER IN WHICH THEY | | | ARE INSTALLED. | | | | | | 4.FBC 435.5.1.3 | | | PRIOR TO CONSTRUCTION, THE FLOOR PLANS | | | AND EQUIPMENT ARRANGEMENT OF ALL NEW | | | INSTALLATIONS, OR MODIFICATIONS OF | | | EXISTING INSTALLATIONS, UTILIZING X-RAY | | | ENERGIES OF 200 KEV AND ABOVE FOR | | | DIAGNOSTIC OR THERAPEUTIC PURPOSES SHALL | | | BE SUBMITTED TO THE DEPARTMENT OF HEALTH | | | FOR REVIEW AND APPROVAL. IN COMPUTATION | | | OF PROTECTIVE BARRIER REQUIREMENTS, THE | | | MAXIMUM ANTICIPATED WORKLOAD, USE | | | FACTORS, OCCUPANCY FACTORS AND THE | | | POTENTIAL FOR RADIATION EXPOSURE FROM | | | OTHER SOURCES SHALL BE TAKEN INTO | | | CONSIDERATION. | | | | | | 5.5 OF A-6 RECEPTION COUNTER, IS | | | SUPPORT BRACKET BLOCKING ACCESSABLITY TO | | | COUNTER? | | | | | | 6.SEE ELECTRICAL REVIEW NOTES | | | REGARDING SIGNING AND SEALING OF PLANS. | | | | | | 7.SUBMIT LOAD CALCULATIONS SHOWING | | | THAT EXISTING FLOOR WILL ACCEPT THIS | | | ADDITIONAL LOAD.ALSO SPECIFY IF | | | EXISTING FLOORING IS POST TENTIONING. | | | SHOW SLAB DETAILS INREGARDS TO CUTTING | | | AND TRENCHING AND THAT THE NECCESSARY | | | CALCULATIONS HAVE BEEN MADE. | | | | | | 8.FBC 435.5.1.3.1.4 SHOW THE TYPE OF | | | OCCUPANCY OF ALL ADJACENT AREAS | | | INCLUSIVE OF SPACE ABOVE AND BELOW THE | | | ROOM CONCERNED. IF THERE IS AN EXTERIOR | | | WALL, THE DISTANCE TO THE CLOSEST AREA | | | WHERE IT IS LIKELY THAT INDIVIDUALS MAY | | | BE PRESENT. | | | | | | 9.IS THE EXTERIOR R.T SHEILDED WINDOW | | | NEW?IF SO SUBMIT PRODUCT APPROVALS PER | | | THE FOLLOWING... | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 10.DOORS SHALL SWING IN THE DIRECTION | | | OF EGRESS TRAVEL WHERE SERVING AN | | | OCCUPANT LOAD OF 50 OR MORE PERSONS. | | | FBC 1008.1.2SEE DOOR 182 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-29 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-29 |
Time |
10:42 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-04 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2007-06-04 12:13:06 | REV'S FOR E2,3,AND E5. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-02 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-01 |
Time |
19:15 |
Sent To |
PC |
|
| Notes |
| 2007-02-01 19:16:27 | IN ELECTRICAL FOR REVIEW. NEW SUBMITTALS BROUGHT IN BY | | | CONTRACTOR ON 1/30 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-20 |
Time |
18:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-19 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2006-12-20 18:46:26 | *** UNSAT 5TH REVIEW *** | | | | | | ** PLEASE SEE NOTES FROM THE FOUR PREVIOUS REVIEWS AS | | | FOLLOWS. | | | PLEASE CALL IS THERE ARE ANY QUESTIONS OR COMMENTS. | | | | | | | | | 1) NOTE:PLEASE SEE NOTE #1 FROM THE PREVIOUS REVIEW | | | DATED 11/16/06. PLEASE SEE THAT THE MANUFACTURES SPECS | | | DO NOT CORRELATE WITH THE SAME INFORMATION AS PROVIDED | | | ON PLANS. PLEASE SEE THE SPECIFIC UNIT IS NOT CHECKED, | | | MARKED, HIGHLIGHTED OR NOTED FOR THE PARTICULAR UNIT. | | | PLEASE SEE THE COMMENTS BELOW. | | | PLEASE SEE SPECS FOR THE ATS WHICH ARE ONLY NOW BEING | | | SUBMITTED FOR REVIEW WOULD STILL NEED TO INDICATE BEING | | | 3R LISTED AS WELL AS RISER INDICATING THE SAME. 90.7, | | | 110.3, | | | FBC 106.1.2 | | | | | | ** PREVIOUS REVIEW NOTES BELOW FROM REVIEW#4 DATED | | | 11/16/06 ** | | | NO, COMMENT NOT FULLY ADDRESSED. PLEASE SEE SPECS WERE | | | SUBMITTED, HOWEVER AS REQUESTED IN THE PREVIOUS REVIEWS | | | PLEASE BE SURE ALL EQUIPMENT CORRELATES FOR USE AND | | | INSTALLATION ETC. | | | PLEASE SEE THE ATS SPECS ARE LISTED AND FOR USE FOR A | | | FIRE PUMP AND SPECIFIES MANY ITEMS FOR NFPA-20?? PLEASE | | | SEE THIS SYSTEM IS PER NFPA-110, 70 AND EQUIPMENT SHALL | | | BE LISTED FOR THE INTENDED USE. PLEASE SEE THE GEN | | | SPECS NOW SUBMITTED STATE CLEARLY A MINIMUM OF | | | 3FT/1METER ON ALL SIDES,, HOWEVER AS STATED REQUIRES | | | MORE CLEARANCE WHEN INSTALLED IN A WP HOUSING FOR DOORS | | | ETC. PLEASE SEE SPACE AS SHOWN DOES NOT SEEM TO MEET | | | THE MINIMUM CLEARANCES FOR UNIT WITH THE WP ENCLOSURE. | | | PLEASE SEE AS NOTE ON SPECS MENTIONS TO PROVIDE | | | ADDITIONAL SPACE FOR DOORS, THIS INFORMATION IS NOT | | | SHOWN ON THE ENCLOSURE SPECS AS SUBMITTED. | | | PLEASE SEE OTHER COMMENTS FOR VENTILATION IN SPECS. | | | PLEASE SEE SPECS DO NOT INDICATE THE SPECIFIC UNIT AND | | | KW RATING, NOTE MENTIONS TO SEE NAMEPLATE, HOWEVER AS | | | THIS IS NOT POSSIBLE, THE KW RATING AS SHOWN ON PLANS | | | INDICATES 42KW, AND THE NEED TO CORRELATE THE | | | MANUFACTURES SPECS AND SIZE OF THE UNIT AND WP IS OF | | | THE UTMOST IMPORTANCE. | | | PLEASE SEE THE CLOSEST UNIT SIZE AND MODEL IS THE 83" | | | LONG, 40" WIDE AND 72" IN HEIGHT. | | | PLEASE KNOW AS THE UNIT AND ENCLOSURE IS NOT SPECIFIED | | | WE ARE UNABLE TO VERIFY. | | | PLEASE ALSO SEE AS SHOWN THE EXHAUST IS STRAIGHT OUT OF | | | THE TOP AS SHOWN ON HOUSING AND THE SPACE BELOW THE | | | UPPER LEVEL FROM THE PARKING DECK DOES NOT PROVIDE | | | CLEARANCE IF THE UNIT IS 72" HIGH. | | | PLEASE SEE COMMENTS FROM MECHANICAL, PLUMBING AND FIRE | | | AND POSSIBLE BLDG COMMENTS NOW THAT THE SPECS ON | | | EQUIPMENT HAVE BEEN SUBMITTED. | | | PLEASE SEE OTHER COMMENTS WHICH REQUIRE READY ACCESS. | | | | | | ** PLEASE KNOW BASED ON THESE COMMENT FOR THE | | | GENERATOR, AND THE POSSIBILITY THAT THE GENERATOR MAY | | | NOT BE PERMITTED TO BE INSTALLED AT THIS LOCATION DUE | | | TO MINIMUM CLEARANCES, ACCESS, VENTILATION, EXHAUST | | | ETC, PERHAPS THE PERMIT AND PLANS SHOULD ALL BE REVISED | | | TO ONLY INCLUDE BUILD OUT OF THE TENANT SPACE AND ALL | | | WILL NOT INCLUDE THE GENERATOR OR ASSOCIATED EQUIPMENT | | | AT THIS TIME. | | | | | | | | | ** PREVIOUS REVIEW COMMENT REVIEW #3** | | | PLEASE KNOW THE FIRST TIME THE MANUFACTURE SPECS/CUT | | | SHEETS FOR THE GEN, ETC WERE SUBMITTED ON THE 3RD | | | REVIEW AND NOTHING MATCHED. PLEASE SEE PREVIOUS NOTES | | | WHICH MENTIONS SPEC SUBMITTED FOR A GASOLINE GENERATOR | | | AND ETC. | | | PLEASE SEE GEN SUBMITTED IS NOW A LP/NAT GAS UNIT, | | | HOWEVER PLEASE SEE PLEASE SUBMIT THE | | | MANUFACTURES SPEC/CUT SHEETS FOR THE GENERATOR, ATS, | | | AND WP HOUSING. | | | PLEASE SEE THAT THIS 3RD REVIEW AND THIS IS FIRST TIME | | | ANY PAPER WORK WAS SUBMITTED HOWEVER THERE IS PAPERWORK | | | SUBMITTED WHICH DO NOT APPLY AT ALL TO GEN ETC. PLEASE | | | SEE "PARTS LIST" BOOK FOR GASOLINE ENGINES FORM FORD | | | MOTOR CORP? | | | PLEASE SEE WARRANTY BOOKS; PLEASE SEE MULTIPLE ATS | | | BOOKS AND SHEETS AND SOME ARE NOT THE SAME | | | EQUIPMENT??? | | | | | | ** PLEASE SUBMIT TWO COMPLETE SETS, WITH ONLY PERTINENT | | | SHEETS RELEVANT TO THIS INSTALLATION. PLEASE PLACE | | | THESE SHEETS INTO SETS BOUND TOGETHER IN A NEAT AND | | | ORDERLY FASHION WITH LABELS OR TABS FOR REVIEW AND | | | STAMPING. | | | | | | FBC 106.1, 106.1.2, 110.3, 90.7 ETC. | | | | | | 2) NOTE: PLEASE SEE REVIEW NOTE #3 FROM THE PREVIOUS | | | REVIEW. | | | PLEASE SEE NOT ENERGY CALCULATIONS/LIGHTING POWER | | | DENSITIES FOR CODE COMPLIANCE WERE SUBMITTED. PLEASE | | | SEE NOTE BELOW WHICH SPEAKS OF THE "BLOCK" LOCATED ON | | | PLANS WHICH DID NOT PROVIDE THE INFORMATION AS NEEDED | | | AND REQUIRED PER 13-415.1.AB.1, 13-415.2. | | | | | | *** PREVIOUS REVIEW NOTE REVIEW, REVIEW #4DATED | | | 11/16/06** | | | NO, PLEASE SEE SAME NOTE AS PREVIOUSLY STATED. THIS | | | WAS REQUIRED AND STATED ON THE FIRST AND ORIGINAL | | | REVIEW ON 02/15/06. PLEASE SEE NOTE #10. PLEASE SEE | | | REVIEW #2, IT WAS THOUGHT THE CALCULATIONS REQUIRED | | | WERE SUBMITTED AND IN PACKAGE, HOWEVER COULD NOT BE | | | LOCATED IN 3RD SUBMITTED SETS OR PACKAGE? PLEASE SEE | | | THAT THIS WAS PREVIOUSLY STATED ON PREVIOUS REVIEW. | | | PLEASE SEE NOW THE RESPONSE IS SHOWING A SMALL BOX WITH | | | A FIGURE SHOWN FOR THIS HOWEVER THIS AS SHOWN IS NOT | | | ENOUGH AND PLEASE SEE SECTIONS AS PREVIOUSLY | | | REFERENCED. | | | PLEASE SEE NOTE BELOW WHICH WAS FROM PREVIOUS REVIEW(S) | | | AND SECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING CALCULATIONS FOR LIGHTING POWER | | | DENSITIES, PER FBC | | | 2004, 13-.AB.1, 13-415.2, 13-415.2.ABC.1, TABLES | | | 415.2.C.1/415.2.B.1. IT WAS THOUGHT THESE WERE | | | SUBMITTED FOR COMPLIANCE WITH THE PREVIOUS REVIEW | | | COMMENTS FOR CHAPTER 13, HOWEVER THESE COULD NOT BE | | | LOCATED IN PACKAGE. IN EITHER CASE, PLEASE SUBMIT. | | | | | | | | | | | | ** NEW NOTE FOR REVIEW NUMBER 5*** | | | | | | 1) NOTE: PLEASE CORRELATE PLANS AND LAYOUT OF | | | MAINS/PANELS AND DISCONNECTS ON RISER WITH THAT OF THE | | | LAYOUT SHOWN ON E-5. | | | PLEASE SEE THE MAIN DISCONNECT FOR THE SECONDARY SIDE | | | OF THE TRANSFORMER COULD NOT BE CLEARLY LOCATED. | | | | | | 2) NOTE: PLEASE SEE AS PLANS ARE NOW INDICATING THE | | | LOCATION OF ALL EQUIPMENT BEING MOVED TO THE NEW | | | LOCATION PLEASE CLARIFY THIS AS THE SUBMITTAL BOOKS FOR | | | THE NEW STRUCTURAL MEZZANINE LEVEL FROM PREVIOUS | | | SUBMITTED PLANS ARE STILL BEING SUBMITTED. PLEASE SEE | | | ANY BUILDING REVIEW COMMENTS. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-12-20 06:52:55 | REVIEW IN PROGRESS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-06 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-06 |
Time |
07:10 |
Sent To |
I |
|
| Notes |
| 2006-11-06 10:40:53 | *** UNSAT 4TH REVIEW *** | | | | | | ** PLEASE SEE NOTES FROM THE THREE PREVIOUS REVIEWS AS | | | FOLLOWS. | | | | | | | | | 1) NOTE:NO, COMMENT NOT FULLY ADDRESSED. PLEASE SEE | | | SPECS WERE SUBMITTED, HOWEVER AS REQUESTED IN THE | | | PREVIOUS REVIEWS PLEASE BE SURE ALL EQUIPMENT | | | CORRELATES FOR USE AND INSTALLATION ETC. | | | PLEASE SEE THE ATS SPECS ARE LISTED AND FOR USE FOR A | | | FIRE PUMP AND SPECIFIES MANY ITEMS FOR NFPA-20?? PLEASE | | | SEE THIS SYSTEM IS PER NFPA-110, 70 AND EQUIPMENT SHALL | | | BE LISTED FOR THE INTENDED USE. PLEASE SEE THE GEN | | | SPECS NOW SUBMITTED STATE CLEARLY A MINIMUM OF | | | 3FT/1METER ON ALL SIDES,, HOWEVER AS STATED REQUIRES | | | MORE CLEARANCE WHEN INSTALLED IN A WP HOUSING FOR DOORS | | | ETC. PLEASE SEE SPACE AS SHOWN DOES NOT SEEM TO MEET | | | THE MINIMUM CLEARANCES FOR UNIT WITH THE WP ENCLOSURE. | | | PLEASE SEE AS NOTE ON SPECS MENTIONS TO PROVIDE | | | ADDITIONAL SPACE FOR DOORS, THIS INFORMATION IS NOT | | | SHOWN ON THE ENCLOSURE SPECS AS SUBMITTED. | | | PLEASE SEE OTHER COMMENTS FOR VENTILATION IN SPECS. | | | PLEASE SEE SPECS DO NOT INDICATE THE SPECIFIC UNIT AND | | | KW RATING, NOTE MENTIONS TO SEE NAMEPLATE, HOWEVER AS | | | THIS IS NOT POSSIBLE, THE KW RATING AS SHOWN ON PLANS | | | INDICATES 42KW, AND THE NEED TO CORRELATE THE | | | MANUFACTURES SPECS AND SIZE OF THE UNIT AND WP IS OF | | | THE UTMOST IMPORTANCE. | | | PLEASE SEE THE CLOSEST UNIT SIZE AND MODEL IS THE 83" | | | LONG, 40" WIDE AND 72" IN HEIGHT. | | | PLEASE KNOW AS THE UNIT AND ENCLOSURE IS NOT SPECIFIED | | | WE ARE UNABLE TO VERIFY. | | | PLEASE ALSO SEE AS SHOWN THE EXHAUST IS STRAIGHT OUT OF | | | THE TOP AS SHOWN ON HOUSING AND THE SPACE BELOW THE | | | UPPER LEVEL FROM THE PARKING DECK DOES NOT PROVIDE | | | CLEARANCE IF THE UNIT IS 72" HIGH. | | | PLEASE SEE COMMENTS FROM MECHANICAL, PLUMBING AND FIRE | | | AND POSSIBLE BLDG COMMENTS NOW THAT THE SPECS ON | | | EQUIPMENT HAVE BEEN SUBMITTED. | | | PLEASE SEE OTHER COMMENTS WHICH REQUIRE READY ACCESS. | | | | | | ** PLEASE KNOW BASED ON THESE COMMENT FOR THE | | | GENERATOR, AND THE POSSIBILITY THAT THE GENERATOR MAY | | | NOT BE PERMITTED TO BE INSTALLED AT THIS LOCATION DUE | | | TO MINIMUM CLEARANCES, ACCESS, VENTILATION, EXHAUST | | | ETC, PERHAPS THE PERMIT AND PLANS SHOULD ALL BE REVISED | | | TO ONLY INCLUDE BUILD OUT OF THE TENANT SPACE AND ALL | | | WILL NOT INCLUDE THE GENERATOR OR ASSOCIATED EQUIPMENT | | | AT THIS TIME. | | | | | | | | | ** PREVIOUS REVIEW COMMENT REVIEW #3** | | | PLEASE KNOW THE FIRST TIME THE MANUFACTURE SPECS/CUT | | | SHEETS FOR THE GEN, ETC WERE SUBMITTED ON THE 3RD | | | REVIEW AND NOTHING MATCHED. PLEASE SEE PREVIOUS NOTES | | | WHICH MENTIONS SPEC SUBMITTED FOR A GASOLINE GENERATOR | | | AND ETC. | | | PLEASE SEE GEN SUBMITTED IS NOW A LP/NAT GAS UNIT, | | | HOWEVER PLEASE SEE PLEASE SUBMIT THE | | | MANUFACTURES SPEC/CUT SHEETS FOR THE GENERATOR, ATS, | | | AND WP HOUSING. | | | PLEASE SEE THAT THIS 3RD REVIEW AND THIS IS FIRST TIME | | | ANY PAPER WORK WAS SUBMITTED HOWEVER THERE IS PAPERWORK | | | SUBMITTED WHICH DO NOT APPLY AT ALL TO THIS GEN ETC. | | | PLEASE SEE "PARTS LIST" BOOK FOR GASOLINE ENGINES FORM | | | FORD MOTOR CORP? | | | PLEASE SEE WARRANTY BOOKS; PLEASE SEE MULTIPLE ATS | | | BOOKS AND SHEETS AND SOME ARE NOT THE SAME | | | EQUIPMENT??? | | | | | | ** PLEASE SUBMIT TWO COMPLETE SETS, WITH ONLY PERTINENT | | | SHEETS RELEVANT TO THIS INSTALLATION. PLEASE PLACE | | | THESE SHEETS INTO SETS BOUND TOGETHER IN A NEAT AND | | | ORDERLY FASHION WITH LABELS OR TABS FOR REVIEW AND | | | STAMPING. | | | | | | FBC 106.1, 106.1.2, 110.3, 90.7 ETC. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE: NO, PLEASE SEE SAME NOTE AS PREVIOUSLY STATED. | | | THIS WAS REQUIRED AND STATED ON THE FIRST AND ORIGINAL | | | REVIEW ON 02/15/06. PLEASE SEE NOTE #10. PLEASE SEE | | | REVIEW #2, IT WAS THOUGHT THE CALCULATIONS REQUIRED | | | WERE SUBMITTED AND IN PACKAGE, HOWEVER COULD NOT BE | | | LOCATED IN 3RD SUBMITTED SETS OR PACKAGE? PLEASE SEE | | | THAT THIS WAS PREVIOUSLY STATED ON PREVIOUS REVIEW. | | | PLEASE SEE NOW THE RESPONSE IS SHOWING A SMALL BOX WITH | | | A FIGURE SHOWN FOR THIS HOWEVER THIS AS SHOWN IS NOT | | | ENOUGH AND PLEASE SEE SECTIONS AS PREVIOUSLY | | | REFERENCED. | | | PLEASE SEE NOTE BELOW WHICH WAS FROM PREVIOUS REVIEW(S) | | | AND SECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING CALCULATIONS FOR LIGHTING POWER | | | DENSITIES, PER FBC | | | 2004, 13-.AB.1, 13-415.2, 13-415.2.ABC.1, TABLES | | | 415.2.C.1/415.2.B.1. IT WAS THOUGHT THESE WERE | | | SUBMITTED FOR COMPLIANCE WITH THE PREVIOUS REVIEW | | | COMMENTS FOR CHAPTER 13, HOWEVER THESE COULD NOT BE | | | LOCATED IN PACKAGE. IN EITHER CASE , PLEASE SUBMIT. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-11-06 07:10:31 | REMOVED FROM INCOMING. IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-24 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-24 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-09-24 00:00:00 | *** UNSAT 3RD REVIEW *** | | | | | | ** PLEASE SEE NOTES FROM THE TWO | | | PREVIOUS REVIEW AS FOLLOWS. | | | | | | | | | 1) NOTE: PLEASE SUBMIT THE | | | MANUFACTURES/SPEC CUT SHEETS FOR THE | | | GENERATOR, ATS, AND WP HOUSING. | | | PLEASE SEE THAT THIS 3RD REVIEW IS FIRST | | | TIME ANY PAPER WORK WAS SUBMITTED, | | | HOWEVER THERE IS PAPERWORK SUBMITTED | | | WHICH DO NOT APPLY AT ALL TO THIS GEN | | | ETC. | | | PLEASE SEE "PARTS LIST" BOOK FOR | | | GASOLINE ENGINES FORM FORD MOTOR CORP? | | | PLEASE SEE WARRANTY BOOKS, PLEASE SEE | | | MULTIPLE ATS BOOKS AND SHEETS AND SOME | | | ARE NOT THE SAME EQUIPMENT??? | | | | | | ** PLEASE SUBMIT TWO COMPLETE SETS, WITH | | | ONLY PERTINENT SHEETS RELEVANT TO THIS INSTALLATION. | | | PLEASE PLACE THIS SHEETS | | | INTO SETS BOUND TOGETHER IN A NEAT AND | | | ODERLY FASHION WITH LABELS OR TABS FOR | | | REVIEW AND STAMPING. | | | | | | FBC 106.1, 106.1.2, 110.3, 90.7 ETC. | | | | | | 2) NOTE: PLEASE SEE THE "S" SHEETS STILL | | | DO NOT CONTAIN THE CORRECT INFORMATION | | | AS REQUIRED UNDER THE FLORIDA | | | ADMINSTRATIVE CODE 61G15-23.002, FLORIDA | | | STATUES 471.023. | | | THIS IS THE 3RD REVIEW FOR THIS NOTE. | | | PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER. PLEASE KNOW, "S" | | | SHEETS MAY BE RETAINED BY THIS OFFICE | | | AND FORWARDED TO THE FBPE'S. | | | | | | 3) NOTE: PLEASE SEE MISSING CALCULATIONS | | | FOR LIGHTING POWER DENSITIES, PER FBC | | | 2004, 13-.AB.1, 13-415.2,13-415.2.ABC.1, | | | TABLES 415.2.C.1/415.2.B.1. IT WAS | | | THOUGHT THESE WERE SUBMITTED FOR | | | COMPLIACNE WITH THE PREVIOUS REVIEW | | | COMMENTS FOR CHAPTER 13, HOWEVER THESE | | | COULD NOT BE LOCATED IN PACKAGE. IN | | | EIHTER CASE , PLEASE SUBMIT. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-02 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-02 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2006-07-02 00:00:00 | *********** UNSAT 2ND REVIEW *********** | | | | | | ** PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEW AND SOME NEW COMMENTS | | | DUE TO SOME MINOR CHANGED ITEMS. | | | | | | ** PLEASE KNOW, PLANS/SUBMITTED | | | MATERIALS ARE NOT COMPLETE AT THIS TIME | | | FOR A COMPLETE REVIEW. | | | | | | ** PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM THE PREVIOUS REVIEW. | | | | | | **************************************** | | | | | | 1A)NOTE: NO , PLEASE SEE SOME SHEETS IN | | | SETS ARE STILL SHOWN WITH SEAL WHICH IS | | | NO LONGER VALID. (S-SHEETS). | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE 61G15-23.001 | | | WHICH REQUIRED THE RAISED | | | SEAL TO CHANGE FROM THE WORDING OF | | | "CERTIFICATE" TO "LICENSE" BY 2/5/04, | | | HOWEVER AN EXTENSION WAS GRANTED BY THE | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS | | | TO DECEMBER 31,2005. | | | PLEASE KNOW SEAL SHALL CONTAIN THE ABOVE | | | WORDING ON RAISED SEAL AS REQUIRED. | | | FS 471.025 | | | ANY SEALED PLANS SHALL BECOME "VOID". | | | PLEASE BE SURE THE NEW RAISED SEAL | | | CONTAINS THE "LICENSE" WORDING. | | | PLEASE CONTACT THIS OFFICE OR THE FBPE'S | | | IF THERE ARE ANY QUESTIONS. | | | | | | *************************************** | | | | | | | | | 1) NOTE; OK, HOWEVER SEE NEXT NOTE. | | | | | | 2) NOTE:OK, HOWEVER PLEASE SEE THAT | | | THE 3POLE 125A BRKR ON GEN SHALL BE | | | "SHUNT TRIP" TYPE AND THE SHUNT TRIP | | | BUTTON SHALL BE GROUPED WITH THE OTHER | | | PUSHBUTTONSBEING PROVIDED AT THE FIRST | | | FLR GENERATOR ANNUCIATOR PANEL/FIRE | | | ALARM PANEL LOCATION. | | | | | | ** PREVIOUE NOTE ** | | | PLEASE SEE ALL DISCONNECTING | | | MEANS FOR POWER FEEDERS ETC SHALL BE | | | GROUPED. | | | 230.72,225.31. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE:NO, PLEASE SEE THIS WAS NOT | | | DONE AND REVIEW OF THESE ITEMS CAN NOT | | | BE DONE AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT ALL SPECS/MANFACTURES CUT | | | SHEETS FOR GENERATOR, ATS ETC. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: OK. | | | | | | 9) NOTE:OK, HOWEVER PLEASE SEE NEW | | | GROUNDING DETAIL FOR TRANSFORMER | | | INDICATES THE NEUTRAL BEING BONDED AT | | | THE TRANSFORMER? PLEASE SEE 250.24B, | | | WHICH REQUIRES THE NEUTRAL TO BE BONDED | | | AT THE FIRST MEANS OF DISCONNECT HOWEVER | | | IN THE SITUATION IT IS PERMITTED. PLEASE | | | SEE THAT BONDING OF THE NEUTRAL IN THE | | | TRANSFORMER WILL THEN REQUIRE ALL | | | GROUNDS AND NEUTRALS TO BE SPLIT AT THE | | | PANEL "P" AND WILL REQUIRE SPECIAL | | | SIGNAGE FOR THE NOTIFICATION FOR NOT TO | | | BOND THE GRND AND THE NEUTRAL BUS AT THE | | | PANEL "P" MCB PANEL. WILL ALSO REQUIRE | | | THE SAME SIGNAGE TO NOTIFY PERSON OF THE | | | BONDING IN THE TRANSFORMER. | | | ** PLEASE KNOW, SIGNAGE AND THE ABOVE | | | SHALL BE PROVIDED, OR THE DETAIL SHOULD | | | NOT HAVE THE NEUTRAL BONDED AT THE | | | TRANSFOMER AND THENEUTRAL AND GRNDS | | | ARE BONDED AT THE PANEL "P" WHICH WOULD | | | BE THE FIRST MEANS OF DISCONNECT. ** *8 | | | THIS OFFICE HAS SEEN THE SCENERIO ON | | | MORE THAN ONE OCCASION WHERE WORK IS | | | BEING PERFORMED IN A PANEL AFTER THE | | | TRANSFORMER AND THE BONDING SCREW OR | | | BONDIGN JUMPER IS ADDED CREATING AN | | | OBJECTIONABLE CURRENT PATH AND | | | PARALLELING THE NEUTRAL. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE PROVIDE GROUNDING | | | ELECTRODE CONNECTION DETAIL(S) FOR THE TRANSFORMER(S). | | | 250.30, 250.58. | | | PLEASE SEE THE CODE SHALL NOT BE | | | REFERENCED IN WHOLE OR IN PART IN LEIU | | | OF THE TECHNICAL INFORMATION REQUIRED ON | | | SAID PLANS. | | | | | | 10)NOTE: OK. | | | | | | 11)NOTE: OK. | | | | | | 12)NOTE: OK. | | | | | | 13)NOTE: NO, THIS IS THE SAME NOTE AND | | | NOTE 1A STILL APPLIES. | | | THESE COMMENTS ARE FOR ALL TRADES AND | | | FOR ALL SHEETS WHETHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THAT ALL TITLE | | | BLOCKS FOR DESIGNERS OF RECORD CONTAIN | | | ALL LICENSING INFORMATION AS REQUIRED | | | UNDER FAC 61G15-23.002, FS 471.023, THIS | | | COMMENT IS NOT FOR STANDROD ENG.\ | | | PLEASE SEE "S" SHEETS. | | | | | | 14)NOTE: OK. | | | | | | ** PLEASE SEE OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH WILL AFFECT ELECTRICAL | | | PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. THIS WILL HELP TO ALLEAVIATE | | | ANY DELAY'S IN PROJECT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-15 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-15 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2006-02-15 00:00:00 | *********** UNSAT *************** | | | | | | ** PLEASE KNOW, PLANS/SUBMITTED | | | MATERIALS ARE NOT COMPLETE AT THIS TIME | | | FOR A COMPLETE REVIEW. | | | | | | **************************************** | | | | | | 1A)NOTE: PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.001 WHICH | | | REQUIRED THE RAISED SEAL TO CHANGE FROM | | | THE WORDING OF "CERTIFICATE" TO | | | "LICENSE" BY 2/5/04, HOWEVER AN | | | EXTENSION WAS GRANTED BY THE FLORIDA | | | BOARD OF PROFESSIONAL ENGINEERS TO | | | DECEMBER 31,2005. | | | PLEASE KNOW SEAL SHALL CONTAIN THE ABOVE | | | WORDING ON RAISED SEAL AS REQUIRED. | | | FS 471.025 | | | ANY SEALED PLANS SHALL BECOME "VOID". | | | PLEASE BE SURE THE NEW RAISED SEAL | | | CONTAINS THE "LICENSE" WORDING. | | | PLEASE CONTACT THIS OFFICE OR THE FBPE'S | | | IF THERE ARE ANY QUESTIONS. | | | | | | *************************************** | | | | | | | | | 1)NOTE; PLEASE SEE LOCATION OF GENERATOR | | | LOCATED ON THE 6TH LEVEL IS NOT | | | PERMITTED BY THIS OFFICE AND FIRE | | | MARSHAL'S OFFICE. | | | PLEASE ALSO SEE ELECTRICAL COMMENTS | | | PERTAINING LOCATION OF DISCONNECTING | | | ETC. | | | | | | 2)NOTE: PLEASE SEE ALL DISCONNECTING | | | MEANS FOR POWER FEEDERS ETC SHALL BE | | | GROUPED. | | | 230.72,225.31. | | | | | | 3)NOTE: PLEASE BE SURE PLANS REFERENCE | | | THE FOLLOWING APPLICABLE CODES, 2002 | | | NFPA-70, 2003 NFPA-101, 2002 NFPA-72, | | | 2002 NFPA-110, 1999 NFPA-75 | | | | | | 4)NOTE: PLEASE SUBMIT ALL | | | SPECS/MANFACTURES CUT SHEETS FOR | | | GENERATOR, ATS ETC. | | | IF THE EPSS IS GOING TO BE INSTALLED | | | UNDER THIS PERMIT, PLEASE INCLUDE. | | | | | | 5)NOTE: PLEASE SEE 645.10,,300.21 FOR | | | LOCATION AND SHUT DOWN OF ELECTRICAL | | | REQUIRED FOR A/C'S AND ALL ALL EQUIPMENT | | | FEEDING IT ROOM. | | | PLEASE SEE A/C SYSTEMS. | | | | | | 6)NOTE: PLEASE SEE 645.5D FOR SD'S AND | | | DETAILS REQUIRED FOR REVIEW AND | | | CONNECTION INTO THE FA SYSTEM. | | | | | | 7) NOTE: PLEASE SHOW AND IDENTIFY AL | | | REQUIREMENTS FOR THE IT ROOM AND | | | REFERENCE NFPA-75 ON ALL P,M, E, | | | ARCHITECTUAL AND STRUCTUAL PLANS. | | | ALL CONTRUCTION, FIRE SPRINKLER | | | PROTECTION AND OR OTHER EXTINGUISHING | | | SYSTEMS SHALL BE PROVIDED. | | | PLEASE MAKE REFERENCE TO THE ROOM | | | PENETRATIONS AS REQUIRED PER CHAPTER 3. | | | ETC | | | | | | 8)NOTE: PLEASE SEE THAT AN EM BATTERY | | | BACK LT OF SOME SORT BE PROVIDED IN THE | | | ELECTRICAL ROOM. | | | 700.16, 101,7.8,7.9 ETC. | | | | | | 9)NOTE: PLEASE PROVIDE GROUNDING | | | ELECTRODE CONNECTION DETAIL(S) FOR THE | | | TRANSFORMER(S). 250.30, 250.58. | | | PLEASE SEE THE CODE SHALL NOT BE | | | REFERENCED IN WHOLE OR IN PART IN LEIU | | | OF THE TECHNICAL INFORMATION REQUIRED ON | | | SAID PLANS. | | | | | | 10)NOTE: PLEASE SEE THE FBC 2004 CHAPTER | | | 13. PLEASE SEE 13-413.1ABC.1 FOR VOLTAGE | | | DROP OF FEEDERS AND BRANCH CIRCUITS. | | | PLEASE SEE 13-415.1.ABC.1.1 FOR LIGHTING | | | CONTROL OF SPCES. | | | TANDEM WIRING PER 13-415.1.ABC.3, .4 | | | PLEASE SEE ALL OF CHAPTER 13 FOR | | | COMMERCIAL SPACES. | | | | | | 11)NOTE: PLEASE CORRELATE ALL CIRCUITING | | | ON PLANS WITH TEH SUBMITTED PANEL | | | SCHEDULES. | | | PLEASE SEE MANY WSH UNITS, A/C 1&2 UNITS | | | ETC. | | | 215.5 | | | | | | 12)NOTE: PLEASE PROVIDE IDENTIFICATION | | | ON PLANS FOR ALL FIXTURES AND CORRELATE | | | WITH THE FIXTURE LEGEND SUBMITTED. | | | | | | 13)NOTE: PLEASE SEE THAT ALL TITLE | | | BLOCKS FOR DESIGNERS OF RECORD CONTAIN | | | ALL LICENSING INFORMATION AS REQUIRED | | | UNDER FAC 61G15-23.002, FS 471.023, THIS | | | COMMENT IS NOT FOR STANDROD ENG.\ | | | PLEASE SEE "S" SHEETS. | | | | | | 14)NOTE: PLEASE SEE THE COMPLETE | | | VALUATION FOR SCOPE OF WORK SHALL | | | INCLUDE ALL LABOR AND MATERIALS, EVEN IF | | | EQUIPMENT IS OWNER SUPPLIED. PLEASE SEE | | | ANY SYSTEM PERMANANTLY INSTALLED, | | | HARDWIRED , FASTENED IN PLACE SHALL BE | | | INCLUDED. | | | FBC ADMINISTRATIVE SECTION 108.3. AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | ** PLEASE SEE OTHER COMMENTS FROM OTHER | | | REVIEWERS WHICH WILL AFFECT ELECTRICAL | | | PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. THIS WILL HELP TO ALLEAVIATE | | | ANY DELAY'S IN PROJECT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE NAY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-11 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-11 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2007-06-11 15:39:46 | *****APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A3 AND E2 WERE DATED, INITIALED, | | | AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-25 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-25 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2007-01-25 15:33:45 | *****APPROVED***** | | | | | | | | | | | | NO ADDITIONAL FIRE PLAN REVIEW NEEDED UNLESS THERE HAS | | | BEEN AN ALTERATION OR REVISION TO THE APPLICABLE PLAN | | | SHEET. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-10-17 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-10-17 |
Time |
09:52 |
Sent To |
I |
|
| Notes |
| 2006-10-17 09:56:14 | ***PROVISO*** | | | | | | 1) SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED FOR | | | GENERATOR INSTALLATION. PLEASE SUBMIT MANUFACTURER SPEC | | | SHEETS AND ALL OTHER APPLICABLE INFORMATION AT THAT | | | TIME. | | | | | | 2) SOFFITTS SHALL NOT INTERFERE WITH FIRE PROTECTION | | | EQUIPMENT. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-13 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-13 |
Time |
11:36 |
Sent To |
|
|
| Notes |
| 2006-07-13 00:00:00 | ***DENIED*** | | | | | | 1) PLEASE NOTE THAT THE FIRE REVIEW IS | | | OK, HOWEVER PLEASE SEE OTHER REVIEW | | | COMMENTS REGARDING FS AND FAC | | | REQUIREMENTS. | | | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHERS TO | | | BE MOUNTED AT DISTANCES NOT TO EXCEED | | | 75' TRAVEL DISTANCE REQUIREMENT. PLEASE | | | ILLUSTRATE ON LS-1. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-03-01 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-27 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | DENIED: | | | | | | 1) THIS PROJECT SHALL COMPLY WITH NFPA | | | 101 LIFE SAFETY CODE, 2003 EDITION AND | | | NFPA 1 UNIFORM FIRE CODE, 2003 EDITION. | | | | | | 2) ON SHEET A1 DOOR #182 SHOULD SWING IN | | | THE DIRECTION OF TRAVEL. | | | | | | 3) PLEASE PROVIDE CUT SHEETS AND SPEC'S | | | ON EQUIPMENT BEING INSTALLED. | | | | | | 4) THE GENERATOR IS NOT PERMITTED ON 6TH | | | FLOOR, PLEASE REFERENCE AND COMPLY WITH | | | NFPA 110 STANDARD FOR EMERGENCY AND | | | STANDBY POWER SYSTEMS, 2002 EDITION, FOR | | | LOCATION, INSTALLATION, AND OTHER | | | REQUIREMENT. | | | | | | 5) PLEASE REFERENCE AND COMPLY WITH NFPA | | | 801 STANDARD FOR FIRE PROTECTION FOR | | | FACILITIES HANDLING RADIOACTIVE | | | MATERIALS, 1998 EDITION. ( X-RAY, | | | MAGNETIC, AND NUCLEAR EQUIPMENT ) | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-01-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-16 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-16 |
Time |
18:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-03 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-03 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. P3 NATURAL GAS RISER. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE GAS | | | PERMIT: | | | A. OK | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****RESPONSE NOTED, BUT GENERATOR SHALL | | | VENT OUT OF THE STRUCTURE AND ABOVE THE | | | ROOF LEVEL. | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****NO MANUF. SPECIFICATION SHEETS | | | SUBMITTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-13 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-03-13 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. P3 NATURAL GAS RISER. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE GAS | | | PERMIT: | | | A. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-28 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-28 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2007-06-28 15:55:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-30 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-30 |
Time |
13:16 |
Sent To |
M |
|
| Notes |
| 2007-05-30 13:16:31 | TO "HMOSER" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-10 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-10 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2007-05-22 09:44:49 | TO "COMM" BD#61 | | 2007-05-10 16:17:10 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
08:37 |
Sent To |
M |
|
| Notes |
| 2007-05-08 08:38:07 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
19:36 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
19:36 |
Sent To |
|
|
| Notes |
| 2006-12-12 10:00:38 | TO "COMM" BD#48 | | 2006-11-29 19:37:13 | WAITING FOR COMMERCIAL BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-06 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-06 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2006-11-07 14:13:49 | TO "COMM" BD#39 | | 2006-11-06 10:59:05 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-15 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-15 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-09-20 00:00:00 | TO "COMM" BD#38 | | 2006-09-15 00:00:00 | WAITING FOR "COMM" BD-NEW SHEETS FOR | | | ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-22 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-22 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | TO "COMM" BD#38 | | 2006-06-22 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2006-03-21 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-01-06 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2006-02-02 00:00:00 | TO "COMM" BD#29/PLANS ON RACK | | 2006-01-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-05-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-05-31 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-05-31 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-05-16 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-05-11 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-13 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-13 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-10 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-10 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2006-10-10 14:06:26 | PASS PROVISO. ADDITIONAL PERMIT REQUIRED FOR GENERATOR | | | .PLEASE PROVIDE EXHAUST ON PLANS,AND EXHAUST | | | TERMINATION ON PLANS.PLAN REVIEW BY HAROLD MOSER | | | 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-07-20 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-07-20 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2006-07-20 00:00:00 | PLAN DENIED | | | 1) PLEASE PROVIDE MANUFACTURERS | | | INSTALLATION INSTRUCTIONS ON THE | | | GENORATOR. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-02-09 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-02-09 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2006-02-09 00:00:00 | PLAN DENIED | | | 1- PLEASE PROVIDE A UL LISTED FLOOR | | | PENETRATION ASSEMBLY FOR THE REFRIGERANT | | | LINES ON A/C 1,2. | | | 2- PLEASE PROVIDE A COPY OF THE | | | MANUFACTURERS INSTALLATION INSTRUCTIONS | | | FOR THE GENERATOR. | | | 3- PLEASE PROVIDE ON THE PLANS THE TYPE | | | OF FUEL USED FOR THE GENERATOR.LOCATION | | | OF FILL PIPE AND VENT LINE. AND LOCATION | | | OF FUEL TANK IF THERE IS ONE. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-09 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-09 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2007-06-09 13:22:18 | REVISION OKSHTS P2 & P4 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-16 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-16 |
Time |
18:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-11 |
Time |
18:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-11 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2006-10-11 18:50:47 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. OK | | | 2. OK - PLANS SHOW TILE TO 4' | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | 8. P3 NATURAL GAS RISER. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE GAS | | | PERMIT: | | | A. OK | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****RESPONSE NOTED, BUT GENERATOR SHALL | | | VENT OUT OF THE STRUCTURE AND ABOVE THE | | | ROOF LEVEL. | | | ****NO RESPONSE, NOT ADDRESSED - SEE | | | ATTACHED SHEET CONCERNING THE EXHAUST | | | FROM THE GENERATOR FROM THE MANUF. SPECIFICATIONS. | | | C.OK | | | 9.OK | | | 10. OK | | | 11. OK | | | 12. OK | | | | | | **************NEW COMMENT************** | | | | | | 1B. FROM LOOKING AT THE MSDS SHEETS, A | | | EYE WASH/EMERGENCY SHOWER WILL BE | | | REQUIRED. SECTION 411. | | | ****NO RESPONSE, NOT ADDRESSED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-02 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-02 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2006-08-02 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT A1 ROOM 108 STAFF TOILET SHALL BE ACCESSIBLE. | | | SUBMIT A DETAIL SHOWING THE FOLLOWING: | | | FOR THE W/C | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.3 HEIGHT | | | C. 11-4.16.4 GRAB BARS | | | D. 11-4.16.5 FLUSH CONTROLS | | | E. 11-4.16.6 DISPENSERS | | | FOR THE LAV | | | A. 11-4.19.2 HEIGHT & CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | C. 11-4.19.4 EXPOSED PIPES & SURFACES | | | D. 11-4.19.5 FAUCETS | | | FOR THE TOILET ROOM | | | A. 11-4.22.3 A 5' TURNING AREA IS | | | REQUIRED. | | | ****RESPONSE NOTED, BUT ELEVATIONS | | | INDICATED ON SHEET A1, (A7 44, 45), ARE | | | NOT ON SHEET A7. PLEASE CLARIFY. | | | | | | 2. SHT A4 SUBMIT INFORMATION ON THE | | | VINYL WALL PAPER SHOWING COMPLIANCE WITH | | | SECTION 1210.2. WALLS SHALL BE | | | NONABSORBENT. | | | ****RESPONSE NOTED, BUT CODE SECTION | | | 1210.2 STATES "WALLS WITHIN 2FT OF | | | URINALS AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NONABSORBENT SURFACE, TO A | | | HEIGHT OF 4 FEET ABOVE THE FLOOR. THE | | | INTENT OF THE CODE IS ALSO FOR CLEAN UP | | | OF THE WALLS. PLEASE SUBMIT A SAMPLE OF | | | THE WALL COVERING SO COMPLIANCE CAN BE DETERMINED. | | | | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | 8. P3 NATURAL GAS RISER. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE GAS | | | PERMIT: | | | A. OK | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | ****RESPONSE NOTED, BUT GENERATOR SHALL | | | VENT OUT OF THE STRUCTURE AND ABOVE THE | | | ROOF LEVEL. | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****NO MANUF. SPECIFICATION SHEETS | | | SUBMITTED. | | | | | | 9.OK | | | 10. OK | | | 11. OK | | | 12. OK | | | | | | **************NEW COMMENT************** | | | | | | 1B. FROM LOOKING AT THE MSDS SHEETS, A | | | EYE WASH/EMERGENCY SHOWER WILL BE | | | REQUIRED. SECTION 411. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-13 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-03-13 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2006-03-13 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT A1 ROOM 108 STAFF TOILET SHALL BE | | | ACCESSIBLE. SUBMIT A DETAIL SHOWING THE | | | FOLLOWING: | | | FOR THE W/C | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.3 HEIGHT | | | C. 11-4.16.4 GRAB BARS | | | D. 11-4.16.5 FLUSH CONTROLS | | | E. 11-4.16.6 DISPENSERS | | | FOR THE LAV | | | A. 11-4.19.2 HEIGHT & CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | C. 11-4.19.4 EXPOSED PIPES & SURFACES | | | D. 11-4.19.5 FAUCETS | | | FOR THE TOILET ROOM | | | A. 11-4.22.3 A 5' TURNING AREA IS | | | REQUIRED. | | | 2. SHT A4 SUBMIT INFORMATION ON THE | | | VINAL WALL PAPER SHOWING COMPLIANCE WITH | | | SECTION 1210.2. WALLS SHALL BE | | | NONABSORBENT. | | | 3. SHTS A6 & A7 TOILET ROOM DETAILS 7 | | | THRU 10, 22, 23, 26, 27, 34 THRU 37. | | | SHOW THE FOLLOWING: | | | FOR THE LAVS | | | A. 11-4.19.4 EXPOSED PIPES & SURFACES | | | B. 11-4.19.5 FAUCETS | | | 4. SHT A6 DETAIL #11 SHOW THE FOLLOWING: | | | FOR THE DRINKING FOUNTAIN: | | | A. 11-4.15.2 SPOUT | | | B. 11-4.15.3 SPOUT LOCATION | | | C. 11-4.15.4 CONTROLS | | | D. 11-4.19.5 CLEARANCES & CLEAR FLOOR | | | SPACE. | | | 5. SHT A7 DETAILS 30 & 32 SHOW THE | | | FOLLOWING FOR THE SINKS. | | | A. 11-4.24.4 SINK DEPTH | | | B. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD | | | APPROACH REQUIRED. CABINET DOORS TO BE | | | REMOVED AS THEY CAN NOT BE IN THE CLEAR | | | FLOOR SPACE) | | | C. 11-4.24.6 EXPOSED PIPES & SURFACES | | | D. 11-4.24.7 FAUCETS | | | 6. ALL PME SHEETS THAT WILL BE | | | RESUBMITTED SHALL HAVE THE NEW SEALS PER | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS | | | RULE. (SEE ATTACHED SHEET). | | | 7. SHT P1 CODE REFERENCED IS FBC-2001. | | | WE HAVE ADOPTED FBC-2004 SINCE 10-01-05 | | | AND ALL PLANS SHALL BE DESIGNED TO THE | | | FBC-2004 AND PLANS SHALL REFERENCE THE | | | 2004 CODE AS WELL. | | | 8. P3 NATURAL GAS RISER. THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE GAS | | | PERMIT: | | | A. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | 9. SHT P3 GAS RISER NOTE #1 REFERENCES | | | FBC-2001 FUEL GAS CODE. GAS CODE IN | | | EFFECT IS FBC-2004 FUEL GAS. PLEASE | | | CHANGE REFERENCE, AND DESIGN TO THE | | | PROPER CODE. | | | 10. SHT P4 FLOOR DRAINS ARE NOT APPROVED | | | INDIRECT WASTE RECEPTORS. A FLOOR SINK | | | OR A HUB DRAIN IS REQUIRED. SECTIONS | | | 803.2 AND 802.3.2. | | | 11. SHT P4 DOMESTIC WATER ISOMETRIC | | | RISER. WATER HAMMER ARRESTORS REQUIRED | | | BY SECTION 604.9 AT THE WASH MACHINE | | | SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS | | | SHOWN. PDI-WH 201 AND MANUFACTURE | | | INSTALLATION INSTRUCTIONS. | | | 12. SHT P4 WATER RISER DIAGRAM, FULL | | | OPEN VALVES ARE REQUIRED AT THE TOP OF | | | ALL WATER DOWN-FEED PIPES. SECTION | | | 606.1(4). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-01-12 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-01-12 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-11-07 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-11-07 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2006-11-07 09:36:16 | FAILED | | | | | | THE CONSTRUCTION OF A MEZZANINE LEVEL TO HOUSE THE | | | GENERATOR REQUIRES THE ADDITION OF PROPORTIONATE | | | PARKING FOR THE NEW SQUARE FOOTAGE.PLEASE PROVIDE A | | | REVISED PARKING TABLE WHICH INCLUDES THE MEZZANINE | | | SQUARE FOOTAGE. | | | | | | ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-10-17 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-10-17 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2006-10-17 13:29:45 | PER 10/16/06 E-MAIL FROM ERIC SCHNEIDER, NO ZONING | | | REVIEW IS REQUIRED BECASE "THE GENERATOR IS INSIDE AND | | | DID NOT REMOVE A PARKING SPACE". |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2006-03-21 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2006-03-21 |
Time |
09:23 |
Sent To |
I |
|
| Notes |
| 2006-03-21 00:00:00 | LOCATION OF GENERATOR OK |
|
|