Plan Review Details - Permit 06010021
Plan Review Stops For Permit 06010021
Review Stop G GAS REVIEW
Rev No 3 Status P Date 2006-08-08 Cont ID  
Sent By mperson Date 2006-08-08 Time 12:01 Rev Time 0.33
Received By mperson Date 2006-08-08 Time 12:01 Sent To  
Notes
2006-08-08 00:00:00RESTAMP: CONTRACTOR LOST PERMIT SET.
  
  
 IF DRYER ROOM IS A CONFINED SPACE, OPEN-
 INGS REQUIRED PER SECTION 304.5 OR
 SECTION 304.6 SHALL BE INSTALLED.
 MINIMUM 1,000 CUBIC FEET REQUIRED.
  
 IF WATER HEATER ROOM IS A CONFINED
 SPACE, OPENINGS REQUIRED PER SECTION
 304.5 OR SECTION 304.6 SHALL BE
 INSTALLED.
 MINIMUM 3,750 CUBIC FEET REQUIRED.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2006-01-26 Cont ID  
Sent By mperson Date 2006-01-26 Time 13:47 Rev Time 1.25
Received By mperson Date 2006-01-26 Time 13:47 Sent To PC
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-01-17 Cont ID  
Sent By mperson Date 2006-01-17 Time 15:44 Rev Time 1.25
Received By mperson Date 2006-01-17 Time 15:44 Sent To PC
Notes
2006-01-17 00:00:00DENIED
  
 REFERENCE: FBC-2004 FUEL GAS
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR GAS PERMIT:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS. THE DRAWING SUBMITTED IS NOT
 AN ISOMETRIC, AND HARD TO UNDERSTAND.
 2. THE GAS SYSTEM SUBMITTED IS SIZED
 INCORRECTLY, PLEASE SIZE CORRECTLY AND
 RESUBMIT. PLEASE SEE ATTACHED LETTERS,
 CORRECTED DRAWINGS, AND CODE TABLES.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561)805-6721

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-02 Cont ID  
Sent By adarroug Date 2006-08-02 Time 14:46 Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 14:46 Sent To G
Notes
2006-08-02 00:00:00TO "G" BOX/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-22 Cont ID  
Sent By adarroug Date 2006-01-22 Time 13:37 Rev Time 0.00
Received By adarroug Date 2006-01-22 Time 13:37 Sent To P
Notes
2006-01-22 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-01-17 Cont ID  
Sent By mperson Date 2006-01-17 Time 15:45 Rev Time 0.00
Received By mperson Date 2006-01-03 Time 11:40 Sent To PC
Notes
2006-01-17 00:00:00DENIED
  
 REFERENCE: FBC-2004 FUEL GAS
  
 THE FOLLOWING INFORMATION IS REQUIRD FOR
 GAS PERMIT:
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. THE DRAWING SUBMITTED IS
 NOT AN ISOMETRIC, AND HARD TO UNDERSTAND
 2. THE GAS SYSTEM SUBMITTED IS SIZED
 INCORRECTLY, PLEASE SIZE CORRECTLY AND
 RESUBMIT. PLEASE READ ATTACHED LETTERS,
 CORRECTED DRAWINGS, AND CODE TABLES.
  
 END OF COMMENTS
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561)805-6721