Plan Review Details - Permit 06010008
Plan Review Stops For Permit 06010008
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-02-07 Cont ID  
Sent By amorse Date 2006-02-07 Time 16:14 Rev Time 0.50
Received By amorse Date 2006-02-07 Time 16:14 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-03-27 Cont ID  
Sent By btrobaug Date 2007-03-27 Time 12:11 Rev Time 0.33
Received By btrobaug Date 2007-03-27 Time 12:06 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-01-31 Cont ID  
Sent By btrobaug Date 2006-01-31 Time 09:01 Rev Time 0.50
Received By btrobaug Date 2006-01-31 Time 07:18 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-02-03 Cont ID  
Sent By mperson Date 2006-02-03 Time 09:15 Rev Time 0.00
Received By mperson Date 2006-02-03 Time 09:15 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-03-20 Cont ID  
Sent By adarroug Date 2007-03-20 Time 09:08 Rev Time 0.00
Received By adarroug Date 2007-03-20 Time 09:08 Sent To E
Notes
2007-03-20 09:08:43TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-03-15 Cont ID  
Sent By adarroug Date 2007-03-15 Time 17:14 Rev Time 0.00
Received By adarroug Date 2007-03-15 Time 17:14 Sent To E
Notes
2007-03-15 17:14:31TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-24 Cont ID  
Sent By spalmer Date 2006-03-24 Time 17:58 Rev Time 0.00
Received By spalmer Date 2006-03-24 Time 17:58 Sent To P
Notes
2006-03-24 00:00:00TO MPERSON DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-27 Cont ID  
Sent By adarroug Date 2006-02-27 Time 08:31 Rev Time 0.00
Received By adarroug Date 2006-02-27 Time 08:31 Sent To P
Notes
2006-02-27 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 14:14 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 14:14 Sent To E
Notes
2006-01-30 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-07 Cont ID  
Sent By amorse Date 2006-02-07 Time 16:14 Rev Time 0.00
Received By amorse Date 2006-01-03 Time 10:45 Sent To  
Notes
2006-01-03 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-03-29 Cont ID  
Sent By mperson Date 2007-03-29 Time 09:00 Rev Time 0.33
Received By mperson Date 2007-03-29 Time 09:00 Sent To PC
Notes
2007-03-29 09:03:00REVISION: MOVE POOL EQUIPMENT AND ADD A LION HEAD, FOR
 A TOTAL OF TWO LION HEADS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-03-27 Cont ID  
Sent By mperson Date 2006-03-27 Time 10:33 Rev Time 0.33
Received By mperson Date 2006-03-27 Time 10:33 Sent To PC
Notes
2006-03-27 00:00:00 
  
  
 ****PROVISO****
 COMPLY WITH FBC-2004 SEC. 424.4 PRIVATE
 SWIMMING POOLS
  
 ****PROVISO****
 FBC-2004 SEC. 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP
 ANSI/NSPI-4 92. AND NSPI-5

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-03-01 Cont ID  
Sent By mperson Date 2006-03-01 Time 13:10 Rev Time 0.33
Received By mperson Date 2006-03-01 Time 13:10 Sent To B
Notes
2006-03-01 00:00:00DENIED 2ND TIME
 REFERENCE:FBC-2004 424.2 SWIMMING POOLS
  
 PLEASE ADJUST YOUR NOTES, AND DETAILS TO
 REFLECT THE FOLLOWING INFORMATION
 REQUIRED FOR PLAN REVIEW:
  
 1) FBC-2004424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (PLEASE ADD "OR AS AN
 ATTACHMENT TO THE SKIMMER" AND PROVIDE
 DETAILS)
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX(561)805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561)6721
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-03 Cont ID  
Sent By mperson Date 2006-02-03 Time 09:16 Rev Time 1.00
Received By mperson Date 2006-02-03 Time 09:16 Sent To B
Notes
2006-02-03 00:00:00DENIED
 REFERENCE: FBC-2004 424.2 SWIMMING POOLS
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW:
  
 1) FBC-2004 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 2) FBC-2004424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.(ADD TO NOTES, AND DETAILS
 REQUIRED)
 3) FBC-2004 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL REQUIRED,
 NOTE: PRINT DRAWING ONLYINDCATES
 REINFORCED CONC. SLAB IT MUST
 INDICATE THE 4" THICKNESS)
 4) FBC-2004 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95 BACKFLOW REQUIRED ON WATER
 SERVICE.(ADD TO NOTES)
 5) FBC-2004 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 6) FBC-2004 424.2.13.2 JOINTS AND
 CONNECTIONS, FBC PLBG. SEC. 605.21
 PURPLE PRIMER REQUIRED ON PVC PIPING
 (ADD TO NOTES)
  
 END OF COMMENTS
  
 REVIEW BY MIKE PERSON
 (561)805-6730
 FAX (561)805-6731
 E-MAIL [email protected]
 UNDRE SUPERVISION OF K.STEVENS
 (561)805-6721
  
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-03-19 Cont ID  
Sent By jroach Date 2007-03-19 Time 17:11 Rev Time 0.00
Received By jroach Date 2007-03-19 Time 17:11 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-01-28 Cont ID  
Sent By mmclean Date 2006-01-28 Time 09:47 Rev Time 0.00
Received By mmclean Date 2006-01-28 Time 09:47 Sent To I
Notes
2006-01-28 00:00:00MUST MEET THE 10FT SETBACK, FROM
 PROPERTY LINE TO WATER'S EDGE.VARIANCE
 3131 (RANDALL GRANBERRY, FORMER PLANNER)