Plan Review Details - Permit 05121223
Plan Review Stops For Permit 05121223
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-24 Cont ID  
Sent By jgomez Date 2006-03-24 Time 10:41 Rev Time 0.33
Received By jgomez Date 2006-03-24 Time 07:47 Sent To  
Notes
2006-03-24 00:00:00BUILDING REVIEW SECOND CHECKLIST:
  
 1- COMMENTS FROM PREVIOUS CHECKLIST WERE
 NOT ADDRESSED. SCOPE OF WORK PROPOSED IN
 THE PERMIT APPLICATION INCLUDES WINDOWS
 REPLACEMENT. INFORMATION REQUESTED ON
 PREVIOUS CHECKLIST WAS NOT SUBMITTED.
 SEE ATTACHED COPY OF FIRST CHECKLIST AND
 ADDRESS COMMENTS REGARDING THE WINDOWS
 REPLACEMENT AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-23 Cont ID  
Sent By jgomez Date 2006-01-23 Time 15:53 Rev Time 0.50
Received By jgomez Date 2006-01-23 Time 15:53 Sent To P
Notes
2006-01-23 00:00:00BUILDING REVIEW CHECKLIST:
 1- GENERAL CONTRACTOR LICENSE CGC008463
 IS SUSPENDED. CONTRACTOR NEEDS TO
 CONTACT DBPR TO RESOLVE LICENSE ISSUES.
 PERMIT CAN'T BE USED IF CONTRACTOR'S
 LICENSE IS SUSPENDED.
  
 2- A) SCOPE OF WORK STATES REPLACING
 BROKEN WINDOWS. PROVIDE FLORIDA OR LOCAL
 PRODUCT APPROVAL FOR WINDOWS TO BE
 INSTALLED.
  
 B) SPECIFY SIZES OF WINDOWS TO BE
 REPLACED TO VERIFY COMPLIANCE WITH
 EGRESS REQUIREMENTS FROM BEDROOMS. SEC.
 505.1 OF FBC 2004 EXISTING BUILDINGS.
  
 C) IF TOTAL NUMBER OF WINDOWS TO BE
 REPLACED AMOUNT TO MORE THAN 25% OF
 GLAZED AREA IN THE HOUSE, THEN STORM
 SHUTTERS ARE REQUIRED. SEC. 507.3 FBC
 2004 EXISTING BUILDINGS.
  
 D) PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR STORM SHUTTERS IF THEY ARE
 REQUIRED. SEE ITEM C) ABOVE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-03-10 Cont ID  
Sent By dpalmer Date 2006-03-10 Time 09:19 Rev Time 0.00
Received By dpalmer Date 2006-03-10 Time 08:58 Sent To M
Notes
2006-03-10 00:00:00********** UNSAT *************
  
 ** PLEASE KNOW, THIS IS THE FIRST TIME
 ELECTRICAL PLANS ARE BEING SUBMITTED FOR
 REVIEW.
  
 1)NOTE: PLEASE CORRELATE ELECTRICAL
 PLANS WITHY MECHANICAL PLANS. NEED TO
 VERFIY EQUIPMENT SIZES FOR AHU, AND CU,
 HOWEVER MECHANICAL PLANS ARE BLANK?
  
 2)NOTE: PLEASE SEE MIN OCP FOR AHU HEAT
 PER 424.3B, 125%.
 PLEASE ALSO SEE OCP LISTED FOR CU SEEMS
 HIGH, PLEASE VERIFY.
 215.5
  
 3)NOTE: PLEASE CORRELATE RISER DIAGRAM
 AND PLANS, AS PLANS INDICATE A MAIN
 DISCONNECT OUTSIDE AND RISER DOES NOT??
 215.5
  
 4)NOTE: PLEASE SEE A DISCONNECT SHALL BE
 REQUIRED FOR WATER HEATER. "PLUG-IN" MAY
 NOT BE USED.
 422.30,31
  
 5)NOTE: PLEASE SEE NO DISCONNECT IS
 BEING SHOWN FOR AHU?
 440.11
  
 6)NOTE: PLEASE SEE NO DISCONNECT IS
 BEING SHOWN FOR CU?
 PLEASE SEE PLANS INDICATEA 220V GFI??
 FOR DISCONNECT?? 440.11
  
 7)NOTE: PLEASE SEE BATH RM RECEPT SHALL
 BE EITHER MOVED IN BETWEEN BOTH LAV'S OR
 ADD AN ADDITIONAL GFI. PLEASE KNOW, YOU
 CAN NOT CROSS OVER A LAV TO PLUG IN AN
 APPLIANCE.
 210.52D.
  
 8)NOTE: PLEASE LIST THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S) PER
 210.52D,210.11C3, THESE SHALL BE 20A,
 #12,
  
 9)NOTE: PLEASE SEE SOME WALL AREAS WHICH
 SEEM TO INDICATE MISSING RECEPTS PER
 210.52
 PLEASE SEE REDLINED LOCATIONS ON PLANS.
  
 10)NOTE: PLEASE SEE 2002 NEC FOR ARC
 FAULT PROTECTION REQUIREMENTS. PLEASE
 SEE NOTES ARE BEING REFERENCED FROM THE
 1999 NEC. PROTECTION IS REQUIRED FOR ALL
 "OUTLETS", FANS, LTS SD'S, ETC.
  
 11)NOTE: PLEASE SEE NOTE ON PLANS
 MENTIOSN TO HAVE SD'S WIRED TO KIT/BATH
 LTS, THIS IS OK, HOWEVER THEN THOSE
 CIRCUITS WOULD ALSO REQUIRE ARC FAULT
 PROTECTION.
 THIS IS OK, HOWEVER, THIS NOT REQUIRED.
 SD'S MAY BE ON ONE OF THE BEDRM
 CIRCUITS.
 THIS IS ONLY A NOTE, HOWEVER IF NOTE
 MENTIONS THIS, THEN THIS IS WHAT WILL BE
 REQUIRED.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 PLEASE REMOVE ANY OLD/VOIDED SHEETS FROM
 SETS AND ONLY INSET NEW REVISED SHEETS
 INTO COMPLETE SETS FOR REVIEW AND
 STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-30 Cont ID  
Sent By dpalmer Date 2005-12-30 Time 14:41 Rev Time 0.00
Received By dpalmer Date 2005-12-30 Time 14:41 Sent To P
Notes
2005-12-30 00:00:00************ UNSAT ************
  
 1)NOTE: PLEASE SEE THAT NO ELECTRICAL
 PLANS WERE SUBMITTED FOR REVIEW.
 PERMIT APPLICATION MENTIONS, TO BRING
 ALL ELECTRICAL UP TO CODE, YET NOTHING
 SUBMITTED FOR THIS?????
 PLEASE SEE FBC 106 WHICH REQUIRES PLANS
 FOR ALL SCOPES MENTIONED ON SAID
 APPLICATION.
  
 ** PLEASE SEE WE ARE CURRENTLY UNDER THE
 2002 NEC(NFPA-70 AND NFPA-72 (2002).
  
 ** PLEASE SEE COMMENTS FROM OTHER
 REVIEWER(S) WHICH WILL REFLECT THE
 PERMIT APPLICATION.
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW. IF
 THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-07 Cont ID  
Sent By adarroug Date 2006-03-07 Time 16:19 Rev Time 0.00
Received By adarroug Date 2006-03-07 Time 16:19 Sent To E
Notes
2006-03-07 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-01-24 Cont ID  
Sent By tgordon Date 2006-01-24 Time 10:44 Rev Time 0.00
Received By tgordon Date 2005-12-29 Time 09:36 Sent To  
Notes
2005-12-29 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-03-15 Cont ID  
Sent By tgordon Date 2006-03-15 Time 10:20 Rev Time 0.20
Received By tgordon Date 2006-03-15 Time 10:20 Sent To P
Notes
2006-03-15 00:00:00*** DENIED ***
 1) NO MECHANICAL PLANS WERE SUBMITTED
 FOR REVIEW. PLEASE SUBMIT MECHANICAL
 PLANS, OR YOU MAY WISH TO VOID YOUR
 MECHANICAL PERMIT #05121225 SO YOUR
 BUILDING PLANS MAY BY-PASS A MECHANICAL
 REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-01-24 Cont ID  
Sent By tgordon Date 2006-01-24 Time 10:30 Rev Time 0.25
Received By tgordon Date 2006-01-24 Time 10:29 Sent To  
Notes
2006-01-24 00:00:00*** DENIED ***
 1) MECHANICAL CONTRACTOR SIGNED ON BUT
 NO MECHANICAL PLANS SUBMITTED, BRINGING
 UP TO CODE IS NOT ACCEPTABLE, NEED MORE
 DETAILED INFOMATION.
  
 2) REFERENCE TO FLOOR PLANS, ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN. PER FBC
 104.2.1 .
  
 3) GENERAL CONTRACTOR'S LICENSE IS
 SUSPENDED PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-03-20 Cont ID  
Sent By jleech Date 2006-03-20 Time 14:44 Rev Time 0.00
Received By jleech Date 2006-03-20 Time 14:44 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-01-24 Cont ID  
Sent By jleech Date 2006-01-24 Time 09:41 Rev Time 0.33
Received By jleech Date 2006-01-24 Time 09:41 Sent To M
Notes
2006-01-24 00:00:00GENERAL CONTRACTOR MUST CORRECT LICENSE
 PROBLEMS BEFORE PLUMBING PLAN REVIEW CAN
 BE DONE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695


Account Summary | Usage Policy | Privacy Policy