| Plan Review Stops For Permit 05121121 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-27 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-27 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)THE PREVIOUS LISTS REQUESTED THAT | | | THE ANCHORING ON THE ANCHORING SCHEDULE | | | AND DETAILS SPECIFIC TO THIS JOB BE | | | CIRCLED.THIS HAS NOT BEEN DONE.THE | | | SHUTTER INSTALLATION SCHEDULE DOES NOT | | | PROVIDE ENOUGH INFORMATION.ON THE | | | SCHEDULE, THE ANCHORING SPECIFIED IS NOT | | | COMPLIANT FOR ALL INSTALLATION DETAILS. | | | | | | 2.)THE PRODUCT APPROVAL FOR THE WINDOW | | | IS INCOMPLETE; THE TOP SECTION OF THE | | | PAGE WITH DESIGN PRESSURES IS CUT OFF. | | | THIS IS REQUIRED TO DETERMINE CODE | | | COMPLIANCE.SUBMIT COMPLETE PRODUCT | | | APPROVALS.THEY MAY BE AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG OR MIAMIDADE.GOV | | | (FIND A DEPARTMENT, BUILDING CODE | | | COMPLIANCE, PRODUCT CONTROL). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-03 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-03 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2006-05-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)THERE IS A LOT OF UNNECESSARY | | | PAPERWORK IN THE PACKAGE, INCLUDING | | | EXTRA ILLEGIBLE PRODUCT APPROVALS, | | | PHOTOCOPIES OF ENGINEERING. PROVIDE ONLY | | | THE FOLLOWING, COLLATED, TWO COPIES: | | | | | | FLOOR PLAN SHOWING LOCATIONS AND SIZES | | | ORIGINAL ENGINEERING | | | FLORIDA STATE PRODUCT APPROVAL(SHUTTERS) | | | SHUTTER EVALUATION REPORT | | | FLORIDA STATE PRODUCT APPROVAL(SGD) | | | SGD EVALUATION REPORT | | | | | | ALL DOCUMENTS ARE TO BE LEGIBLE. | | | | | | 2.)THE PREVIOUS LISTS REQUESTED THAT | | | THE ANCHORING ON THE ANCHORING SCHEDULE | | | AND DETAILS SPECIFIC TO THIS JOB BE | | | CIRCLED.THIS HAS NOT BEEN DONE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-04-19 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-04-19 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)CIRCLE THE APPLICABLE DETAILS | | | SPECIFIC TO THIS JOB ON THE PRODUCT | | | APPROVAL.CIRCLE THE ANCHOR YOU ARE | | | USING ON SHEET 5.CODE COMPLIANCE | | | (ANCHOR SPACING) CANNOT BE DETERMINED AS | | | NOT ENOUGH INFORMATION WAS PROVIDED. | | | | | | NOT ADDRESSED. THE PRODUCT APPROVAL HAS | | | CHANGED; ANCHORING NOW FOUND ON 7&8. | | | NOT ALL CONNECTIONS ARE COMPLIANT FOR | | | THIS DESIGN PRESSURE. | | | | | | 2.)PROVIDE INFORMATION AS TO HOW YOU | | | DETERMINED THAT THE OPENINGS ARE IN ZONE | | | 4 RATHER THAN ZONE 5. | | | | | | NOT ADDRESSED. | | | | | | 3.)THE ARCH ALUMINUM NOAS ARE | | | ILLEGIBLE.CODE COMPLIANCE CANNOT BE | | | DETERMINED AS I CANNOT READ THE DESIGN | | | PRESSURE LIMITATIONS. | | | | | | NOT ADDRESSED.ON THE SLIDING GLASS | | | DOOR PRODUCT APPROVAL, CIRCLE DETAILS | | | AND ANCHORING SPECIFIC TO THIS JOB TO | | | SHOW CODE COMPLIANCE. | | | | | | 4.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | IT WAS PROVIDED FOR THE SHUTTERS.FOR | | | THE ARCH ALUMINUM, A 2001 STATE APPROVAL | | | WAS SUBMITTED.PRINT THE 2004 STATE | | | APPROVAL, IF AVAILABLE.IF IT IS NOT | | | AVAILABLE, A LOCAL PRODUCT APPROVAL WILL | | | BE ISSUED. | | | | | | THE APPLICATION STATES THAT GLASS DOORS | | | WILL BE REPLACED.THE SKETCH INDICATES | | | THAT YOU ARE LEAVING THE EXISTING. | | | CLARIFY SCOPE OF WORK. | | | | | | 5.)ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-20 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-01-17 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2004 | | | | | | 1.)CIRCLE THE APPLICABLE DETAILS | | | SPECIFIC TO THIS JOB ON THE PRODUCT | | | APPROVAL.CIRCLE THE ANCHOR YOU ARE | | | USING ON SHEET 5.CODE COMPLIANCE | | | (ANCHOR SPACING) CANNOT BE DETERMINED AS | | | NOT ENOUGH INFORMATION WAS PROVIDED. | | | | | | 2.)PROVIDE INFORMATION AS TO HOW YOU | | | DETERMINED THAT THE OPENINGS ARE IN ZONE | | | 4 RATHER THAN ZONE 5. | | | | | | 3.)THE ARCH ALUMINUM NOAS ARE | | | ILLEGIBLE.CODE COMPLIANCE CANNOT BE | | | DETERMINED AS I CANNOT READ THE DESIGN | | | PRESSURE LIMITATIONS. | | | | | | 4.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 5.)PROVIDE A COPY OF THE CONDO | | | ASSOCIATION APPROVAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-15 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2006-06-15 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-03 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-03 |
Time |
11:47 |
Sent To |
B |
|
| Notes |
| 2006-05-03 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-14 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-14 |
Time |
14:47 |
Sent To |
B |
|
| Notes |
| 2006-04-14 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-20 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-12-28 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2005-12-28 00:00:00 | TO "MISC" BOX#1 |
|
|