| Plan Review Stops For Permit 05121076 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-19 |
Time |
16:47 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-05-19 |
Time |
16:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-16 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-05-16 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-25 |
Time |
11:15 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-04-25 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | DENIED | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR | | | EXTERIOR DOORS AND LINTELS. | | | | | | 5.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-06 |
Time |
09:45 |
Rev Time |
4.00 |
| Received By |
alange |
Date |
2006-03-06 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 3.SHOW CORRECT BUILDING CONSTRUCTION | | | TYPE.TYPE IV IS NOT CORRECT.SEE FBC | | | 2004. | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR | | | EXTERIOR DOORS AND LINTELS. | | | | | | 5.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL.WPB | | | AMMENDMENT TO FBC 106.3.3 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-18 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-18 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2006-05-18 00:00:00 | *** PLANS MADE INTO TWO COMPLETE SETS. | | | | | | PLANS SHALL BE ROUTED TO ALL TRADES FOR | | | RE-STAMPING. | | | | | | | | | NO TITLE BLOCK ON "S" SHEETS FOR | | | ENGINEER. BUILDING REVIEW TO FOLLOW UP | | | ON THIS. | | | | | | | | | ELECTRICAL SHEETS STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-05-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-16 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-16 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2006-05-16 00:00:00 | ******* UNSAT 3RD REVIEW ******* | | | | | | | | | 1) NOTE: PLEASE SEE COMMENT # 1 FROM THE | | | TWO PREVIOUS , WHICH REQUESTED THE | | | CERTIFICATE OF AUTHORIZATION NUMBER FOR | | | "AE DESIGN INC" TO BE PLACED ON TITLE | | | BLOCKS AS REQUIRED UNDER FS 481.219, AND | | | FAC 61G1-16.004. | | | PLEASE KNOW, BOTH NOTES REQUESTED THIS | | | FOR "ALL TRADES" AND FOR "ALL" SHEETS | | | CONTAINING SAID TITLE BLOCKS WHETHER | | | COMMENT WAS MADE BY ANY OTHER | | | REVIEWER(S). | | | PLEASE SEE ALL MEP SHEETS INCLUDING NEW | | | ELECTRICAL CONTAIN THE SAME | | | ARCHITECTURAL FIRM'S TITLE BLOCK WITH | | | OUTTHE CA #. | | | PLEASE REVISE THESE SHEETS TO CORRELATE | | | WITH THE REVISED "A" SHEETSOR INCLUDE | | | THE REQUIRED CA #. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-24 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-24 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2006-04-24 00:00:00 | ******** UNSAT2ND REVIEW ******** | | | | | | ** PLEASE SEE SOME NOTES FROM FIRST | | | REVIEW AND NEW NOTE WHICH NEED TO BE | | | ADDRESSED. | | | SEE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW AND LABLED ACCORDINGLY. | | | | | | 1)NOTE:NO, PLEASE SEE THE MISSING | | | CETIFICATE OF AUTHORIZATION NUMBER FOR | | | ARCHITECTURAL FIRM COULD NOT BE LOCATED | | | ON SIAD SHEETS. | | | THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES.** | | | PLANS ARE LABLED THAT THIS # IS PENDING. | | | PLEASE KNOW, UNTIL SUCH CA # IS ISSUED | | | FROM THE STATE, PLANS MAY NOT LIST | | | ANYTHING OTHER THAN THE ARCHITECT AS AN | | | INDIVIDUAL. | | | THIS A FLORIDA STATUE AND THERE ARE NO | | | EXCEPTIONS. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE MISSING INFORMATION | | | AS REQUIRED FOR TITLE BLOCKS FOR | | | ARCHITECTUAL FIRM. PLEASE SEE MISSING | | | PRINTED NAME AND LICENSE # FOR SAID | | | ARCHITECT. PLEASE SEE MISSING | | | CERITFICATE OF AUTHORIZATION NUMBER. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G1-16.001, ABD FLORIDA STATUES 481.219 | | | * PLEASE KNOW THIS IS REQUIRED ON ALL | | | SHEETS AND FOR ALL TRADES WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S)> | | | PLEASE SEE THIS COMMENT IS FOR | | | ARCHITECTUAL FIRM AS ENGINEER FIRM SHOWS | | | INFORMATION AS NEEDED, HOWEVER TITLE | | | BLOCK FOR ARCH FIRM ARE LOCATED ON | | | ENGINEERED PLANS. | | | | | | 2)NOTE: OK. | | | | | | 3)NOTE: OK. | | | | | | 4)NOTE: OK, NEW SERVICE. | | | | | | 5)NOTE: OK, NEW SERVICE. | | | | | | 6)NOTE:OK, NEW SERVICE. | | | | | | 7)NOTE:NO, PLEASE SEE TABLE 450.3, A | | | MAXOCP FOR THIS 225 KVA TRANSFORMER IS | | | 350A'S. (125%). CAN NOT USE THE 250% ASS | | | THI DOES NOT MEET THE EXCCEPTIONS AS | | | NOTED IN TABLE. PLEASE REVISE THE 400A | | | OCP AS SHOWN. | | | | | | ** PREVIOUS NOTE** | | | PLEASE SEE MAX OCP FOR TRANSFORMER TO BE | | | 125% OR PERMITTED TO PROCEED TO THE | | | STANDARD OF OCP. | | | PLEASE SEE 450.3,240.6 | | | | | | 8)NOTE: OK. | | | | | | 9)NOTE: OK. | | | | | | 10)NOTE: OK, NOTED AS 125% FOR THE | | | ENTIRE SERVICE ABOVE THE MIN FOR | | | CONTINOUS LOADS. OK. | | | | | | 11)NOTE: OK. | | | | | | 12)NOTE: OK. | | | | | | 13)NOTE: OK. | | | | | | NEW NOTE** | | | | | | 14) NOTE: PLEASE SEE FBC CHAPTER 13, | | | 13-415.1.ABC.1.1 , .2 AND .3. | | | PLEASE SEE SPACE CONTROL IN SEPARATE | | | SPACES AS A TIME CLOCK IS BEING SHOWN | | | FOR MAIN BLDG, HOWEVER LIGHTING CONTROLS | | | IN SEPARATE SPACES ARE REQUIRED. PLEASE | | | SPECIFY AT LOCATIONS ON LIGHTING PLANS | | | AND DETAIL DEVICES TO BE IMPLEMENTED. | | | PLEASE KNOW, IF USING A TIMED DEVICE, | | | NOT MORE THAN 4HRS ON OVER-RIDE IS | | | PERMITTED. | | | THIS DOES NOT INCLUDE AREAS OF REQUIRED | | | EGRESS. | | | | | | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECRTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT "NEW REVISED" SHEETS | | | INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. PLEASE ONLY SUBMIT ONE COPY OF | | | THE OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-08 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | IN ELEC FOR REVIEW. | | | ******** UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | | AS REQUIRED FOR TITLE BLOCKS FOR | | | ARCHITECTUAL FIRM. PLEASE SEE MISSING | | | PRINTED NAME AND LICENSE # FOR SAID | | | ARCHITECT. PLEASE SEE MISSING | | | CERITFICATE OF AUTHORIZATION NUMBER. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE | | | 61G1-16.001, ABD FLORIDA STATUES 481.219 | | | * PLEASE KNOW THIS IS REQUIRED ON ALL | | | SHEETS AND FOR ALL TRADES WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S)> | | | PLEASE SEE THIS COMMENT IS FOR | | | ARCHITECTUAL FIRM AS ENGINEER FIRM SHOWS | | | INFORMATION AS NEEDED, HOWEVER TITLE | | | BLOCK FOR ARCH FIRM ARE LOCATED ON | | | ENGINEERED PLANS. | | | | | | 2)NOTE: PLEASE BE SURE PLANS AND DESIGN | | | REFLECT CURRENT CODES IN EFFECT. PLEASE | | | SEE AS OF OCT 1ST,2005, THE CODE HAS | | | CHANGED TO THE 2004 FLORIDA BLDG CODE. | | | PLEASE ALSO ADJUST OTHER CODES | | | ACCORDINGLY. | | | PLEASE SEE A0.1 WHICH MENTIONS A 2001 | | | NEC? PLEASE KNOW THE NFPA-70 (NEC) WENT | | | FROM THE 1999 TO 2002 ON JULY 1ST,2003. | | | THE 2002 NFPA-70 IS CURRENTLY THE CODE | | | IN EFFECT. PLEASE ALSO MAKE REFERENCE TO | | | THE CURRENT 2003 NFPA-101,2002 NFPA-72. | | | | | | 3)NOTE: PLEASE PROVIDE A COMMON | | | GROUNDING RISER FOR SYSTEMS PROPOSED. | | | PLEASE SEE 250.30,250.58. PLEASE SHOW A | | | ONE-LINE DIAGRAM FOR THE SYSTEMA DN THE | | | ATTACHMENT POINTS. | | | ** PLEASE ALSO VERIFY/NOTE THE LOCATION | | | IN WHICH THE SEPARATELY DERIVED SYSTEM | | | SHALL BE BONDED. (FIRST MEANS OF | | | DISCONNECT)? 250.24, 250.66 | | | | | | 4)NOTE: PLEASE SEE 225.31- 225.39 FOR | | | THE MEANS OF DISCONNECT REQUIRED AT THE | | | BLDG AS THE SERVICE MEANS OF DISCONNECT | | | IS BEING SHOWN "DETACHED " FROM THE | | | BLDG. PLEASE ALSO SEE 230.70 ETC FOR | | | SERVICE MEANS OF DISCONNECT AND | | | LOCATION. | | | | | | 5)NOTE: PLEASE SEE DETAIL NOTE MENTIONS | | | TO MOUNT THE SERVICE MEANS OF DISCONNECT | | | ON FENCE AND TO SEE DETAIL ON 2.1. | | | PLEASE KNOW, A FENCE DETAIL FOR TYPE AND | | | CONTRUCTION COULD NOT BE LOCATED ON 2.1. | | | THIS MUST BE A STRUCTUALLY SOUND AND | | | SUPPORTIVE TYPE OF INSTALLATION. | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE 250.32 FOR GROUNDING | | | ELECTRODE SYSTEM TO BE LOCATED AT THE | | | DETACHED BLDG AS SERVICE IS NOT ON OR | | | LOCATED AT THE MAIN BLDG. | | | | | | 7)NOTE: PLEASE SEE MAX OCP FOR | | | TRANSFORMER TO BE 125% OR PERMITTED TO | | | PROCEED TO THE STANDARD OF OCP. | | | PLEASE SEE 450.3,240.6 | | | | | | 8)NOTE: PLEASE SEE A "POWER CONDITIONER" | | | IS SHOWN ON RISER BEING FED FROM MDP, | | | HOWEVER THIS COULD NOT BE LCATED ON SAID | | | PANEL SCHEDULE? | | | 215.5 | | | | | | 9)NOTE: PLEASE SEE MISSING PANEL(S) L1 | | | AND N SCHEDULES? | | | 215.5 | | | | | | 10)NOTE: PLEASE SEE ALL CONTINUOUS LOADS | | | SHALL BE SHOWN AND BASED ON 125%. | | | 215.3,2230.42 ETC . | | | | | | 11)NOTE: PLEASE PORVIDE AN EMERGENCY | | | BATTERY BACK UP TYPE OF LT FIXTURE IN | | | ELECTRICAL ROOM. | | | 700.16,LS101 7.8,7.9 | | | | | | 12)NOTE: PLEASE SHOW ALL CONDUCTOR SIZES | | | ON PANEL SCHEDULES FOR ALL BRANCH | | | CIRCUITS. | | | 215.5,240.4,310.16 | | | | | | 13)NOTE: PLEASE PROVIDE GROUNDING DETAIL | | | FOR PHONE SYSTEMS. INSTALLATION ENTERING | | | THE BLDG. | | | 800.11,800.33,40,44 ETC. | | | | | | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECRTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT "NEW REVISED" SHEETS | | | INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. PLEASE ONLY SUBMIT ONE COPY OF | | | THE OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-05-19 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-05-19 |
Time |
15:37 |
Sent To |
B |
|
| Notes |
| 2006-05-19 00:00:00 | APPROVED PER MIKE WENNERGREN/PLANS | | | STAMPED 5-19-06. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-04-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-25 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-25 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-02-08 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-02-08 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | ******DENIED****** | | | | | | 1) SHT A0.2 ILLUSTRATES (2) SETS OF | | | DOORS THAT ARE OPPOSING TO EACH OTHER. | | | DOORS SHALL SWING IN DIRECTION OF TRAVEL | | | WHERE SERVING OCCUPANT LOAD GREATER THAN | | | 50. | | | | | | 2) REQUIRED BUILDING FIRE PROTECTION | | | SYSTEMS AND MEANS OF EGRESS NOT | | | IMMEDIATELY EFFECTED BY THIS WORK TO BE | | | MAINTAINED DURING THIS PROJECT. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | 4) WILL THE NEW LOCK AND CARD READER | | | ACCESS SYSTEM IMPACT THE MEANS OF | | | EGRESS? | | | | | | 5) DUCT SMOKE DETECTORS SHALL BE | | | INSTALLED IN AIR SUPPLY SYSTEM, AND | | | INITIATE A GENERAL FIRE ALARM WHEN | | | ACTIVATED IN ACCORDANCE WITH LOCAL | | | REQUIREMENT. | | | | | | 6) DRAWING INDEX INDICATES A FIRE | | | PROTECTION SHEET THAT APPEARS TO HAVE | | | BEEN REMOVED PRIOR TO THIS REVIEW. | | | | | | 7) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 8) PLEASE SEE APPLICABLE CODE REVIEW. | | | NFPA 101, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2006-05-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-29 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-29 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2006-04-18 00:00:00 | TO "COMM" BD#56 | | 2006-03-29 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-06 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-12-27 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2006-01-26 00:00:00 | TO "COMM" BD#41 | | 2005-12-27 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-05-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-05-19 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2006-05-19 00:00:00 | PROVISO: | | | RTU'S 1 THROUGH 3 ARE REQUIRED TO HAVE | | | DUCT SMOKE DETECTORS IN ACCORDANCE WITH | | | 2004 FMC 606.2.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-19 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-05-18 |
Time |
06:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-04-26 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-04-26 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2006-04-26 00:00:00 | PROVISO: | | | RTU'S 1 THROUGH 3 ARE REQUIRED TO HAVE | | | DUCT SMOKE DETECTORS IN ACCORDANCE WITH | | | 2004 FMC 606.2.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-15 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-15 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2006-02-15 00:00:00 | DENIED: | | | 1.PLAN SHEET A0.1 BUILDING CODE REVIEW | | | INDICATES THE 2001 FLORIDA BUILDING | | | CODE.AS OF OCTOBER 1, 2005 THE 2004 | | | FLORIDA BUILDING CODE WENT INTO EFFECT. | | | | | | | | | 2.PLEASE CLARIFY CLEARANCE FOR SERVICE | | | AND REPLACEMENT OF THE ACWS.PLAN SHEET | | | M-3 DOES NOT APPEAR TO GIVE ANY | | | CLEARANCE.SHOW COMPLIANCE WITH 2004 | | | 306.1. | | | | | | 3.PLEASE INDICATE DUCT SMOKE DETECTORS | | | ON PLAN IN ACCORDANCE WITH 2004 FMC | | | 606.2.1 | | | | | | 4.PLAN SHEET M-4 ROOF TOP DETAIL, | | | PLEASE INDICATE TERMINATION OF | | | CONDENSATE.PLEASE NOTE, PVC INSTALLED | | | ON THE ROOF SHALL HAVE PROTECTION FROM | | | UV RAYS.PROVIDE INFORMATION HOW THIS | | | WILL BE ACCOMPLISHED. | | | | | | 5.PROVIDE DETAIL OF THE SUPPORT FOR | | | THE CONDENSATE LINE. | | | | | | 6.PLAN SHEET M-4 PROVIDES SUPPORT | | | DETAIL FOR THE RTU.PLEASE INDICATE | | | SUPPORT DETAIL FOR THE CHILLER ALSO. | | | PLEASE EQUIPMENT & SUPPORTS EXPOSED TO | | | THE WIND SHALL BE DESIGNED & INSTALLED | | | FOR TO RESIST WIND PRESSURES ON THE | | | EQUIPMENT & SUPPORTS AS DETERMINED IN | | | CHAPTER 16 OF THE 2004 FBC. | | | | | | PLEASE PROVIDE INSTALLATION INSTRUCTIONS | | | FOR EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-01-18 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-01-18 |
Time |
14:33 |
Sent To |
PC |
|
| Notes |
| 2007-01-18 14:34:26 | REVISION FOR VENTS AND CLEAN OUTS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-05-18 |
Time |
06:56 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-05-18 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2006-05-19 00:00:00 | RE STAMP PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-04-20 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-04-20 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2006-04-20 00:00:00 | PROVISO:\SHT P-3 SEC 606.1 (4) DOWN FEED | | | SOV. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-25 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-25 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2006-02-25 00:00:00 | PLUMBING PLAN REVIEW EXAMINER | | | PAUL SCHMITZ 561-805-6692 | | | [email protected] | | | FBC PLUMBING 2004 | | | FBC FUEL GAS 2004 | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | CH 1, ADMINISTRATION, 2004 EDITION ( | | | ATFBC)FBC BUILDING 2004, CH 11 | | | DENIED | | | | | | 1) SHT A9-1BREAK ROOM #102,122. | | | DEETAIL 4/A9.3, 9/A9.1 | | | DEPTH OF SINK SHALL BE A MAXIMUM OF | | | 6-1/2 INCHES. | | | 2) SHT A8.1 JANITOR CLOSET RM #126, | | | SHOW EXISTING SERVICE SINK. | | | 3) SHT A8.1 DRINKING FOUNTAIN NOT SHOWN | | | (A)WHERE ONLY ONE DRINKING FOUNTAIN IS | | | PROVIDED ON A FLOOR, THERE SHALL BE A | | | DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO | | | INDIVIDUALS WHO USE WHEELCHAIRS IN | | | ACCORDANCE WITH SECTION 11-4.15 AND ONE | | | ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY | | | BENDING OR STOOPING. (THIS CAN BE | | | ACCOMMODATED BY THE USE OF A ?HI-LO? | | | FOUNTAIN; BY PROVIDING ONE FOUNTAIN | | | ACCESSIBLE TO THOSE WHO USE WHEELCHAIRS | | | AND ONE FOUNTAIN AT A STANDARD HEIGHT | | | CONVENIENT FOR THOSE WHO HAVE DIFFICULTY | | | BENDING; BY PROVIDING A FOUNTAIN | | | ACCESSIBLE UNDER SECTION 11-4.15 AND A | | | WATER COOLER; OR BY SUCH OTHER MEANS AS | | | WOULD ACHIEVE THE REQUIRED ACCESSIBILITY | | | FOR EACH GROUP ON EACH FLOOR.) | | | (B)WHERE MORE THAN ONE DRINKING | | | FOUNTAIN OR WATER COOLER IS PROVIDED ON | | | A FLOOR, AT LEAST 50 PERCENT OF THOSE | | | PROVIDED SHALL COMPLY WITH SECTION | | | 11-4.15 AND SHALL BE ON AN ACCESSIBLE | | | ROUTE. | | | 4) SHT P-3 WATER RISER, SEC 606.1 (4) | | | FULLY OPEN VALVES SHALL BE INSTALLEDIN | | | THE FOLLOWING LOCATIONS.ON EVERY WATER | | | DOWN FEED PIPE. | | | 5) SHT P.3 WATER RISER. | | | SEC 604.9 WATER HAMMER. A WATER HAMMER | | | ARESSTOR SHALL BE INSTALLED WHERE QUICK | | | CLOSING VALVES ARE UTILIZED. | | | COMPLY WITH ASSE 1010 | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|