Plan Review Details - Permit 05121016
Plan Review Stops For Permit 05121016
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-02 Cont ID  
Sent By mjacobs Date 2006-02-02 Time 11:55 Rev Time 0.00
Received By mjacobs Date 2006-02-02 Time 09:50 Sent To  
Notes
2006-02-02 00:00:00 
 1)CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE
 BUILDING OFFICIAL (SEE ALSO SECTION
 106.3.5 ). ALSO THE CONSTRUCTION
 DOCUMENTS SHALL BE PREPARED BY A DESIGN
 PROFESSIONAL WHERE REQUIRED BY THE
 STATUTES. WHERE SPECIAL CONDITIONS
 EXIST, THE BUILDING OFFICIAL IS
 AUTHORIZED TO REQUIRE ADDITIONAL
 CONSTRUCTION DOCUMENTS TO BE PREPARED BY
 A DESIGN PROFESSIONAL
  
  
 2) A DETAIL DRAWING OF THE EXISTING WOOD
 STRUCTURE IS REQUIRED SHOWING THE TYPE
 OF DECK THAT EXISTS OR WHICH WILL BE
 BUILT. SHOW ALL STRUCTUAL DETAILS WHICH
 WILL BE SUPPORTING THE NEW SCREEN
 ENCLOSURE.
  
 3)1805.2 DEPTH OF FOOTINGS .
 THE MINIMUM DEPTH OF FOOTINGS BELOW THE
 UNDISTURBED GROUND SURFACE SHALL BE 12
 INCHES. GIVE A FOOTING DETAIL OF THE NEW
 FOUNDATION SUPPORTING THE SECOND STORY
 SCREEN ENCLOSURE.
  
 4) SHOW THE ELEVATION WITH THE PROPOSED
 NEW STRUCTURE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-12 Cont ID  
Sent By adarroug Date 2006-01-12 Time 12:29 Rev Time 0.00
Received By adarroug Date 2006-01-12 Time 12:29 Sent To B
Notes
2006-01-12 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-02-02 Time   Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 09:05 Sent To  
Notes
2005-12-27 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-09 Cont ID  
Sent By mmclean Date 2006-01-09 Time 14:32 Rev Time 0.00
Received By mmclean Date 2006-01-09 Time 14:11 Sent To I
Notes
2006-01-09 00:00:00DENIED,
 1. NEED TO PROVIDE TWO SETS OF
 ELEVATIONS PLANS AND PROVIDE FLOOR PLAN
 WITH INTERIOR ACCESS TO THE 2ND FLOOR
 ENCLOSURE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved