| Plan Review Stops For Permit 05121002 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-08 |
Time |
14:04 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-05-08 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | REVISION TO DRYWALL CEILINGS APPROVED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-06 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-01-06 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2006-07-11 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-27 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-27 |
Time |
15:24 |
Sent To |
FIRE |
|
| Notes |
| 2006-06-27 00:00:00 | ******* UNSAT********* | | | | | | 1) NOTE: PLEASE CORRELATE ELECTRICAL | | | PLANS WITH BUILDING REFLECTED CEILING | | | PLANS. | | | PLEASE SEE EM LTS,,,, | | | PLEASE SEE JOB BOXES SHOWN FOR FANS. | | | | | | 2) NOTE: PLEASE SEE MISSING MIN EGRESS | | | LIGHTING. PLEASE SEE NOW LOCATIONS WHICH | | | REQUIRE A LT FIXTURE OF SOME SORT FOR | | | EGRESS IS ONLY SHOWING "J" BOX.?? | | | PLEASE SEE LS101 7.8, 7.9, 2003 | | | PLEASE SEE BATH RM SHOWS THE NEW GFI, | | | ONLY NO NEW OR EXISTING LTS ARE SHOWN? | | | CONTROL? | | | | | | | | | 3) NOTE: PLEASE SEE AHU HEAT IS SHOWN AS | | | 5.5KW AND YET THE OCP SEEMS HIGH AT 60A. | | | IS THIS 5.5KW PER PHASE? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-26 |
Time |
20:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-26 |
Time |
20:24 |
Sent To |
|
|
| Notes |
| 2006-04-26 00:00:00 | ***** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE REDLINED PLANS FROM | | | DEC 05, WHICH REQUESTED ALL CIRCUITING | | | TO BE PLACED ON PLANS FOR SCOPE OF WORK | | | AND TO CORRELATE WITH A PANEL SCHEDULE | | | TO BE SUBMITTED. | | | THIS WAS A CONDITION SET UP WITH | | | ARCITECT IN ORDER TO HAVE PERMIT ISSUED | | | ANDCIRCUITS NOT KNOWN AT THAT TIME. | | | PLEASE ADDRESS.215.5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-29 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-29 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2005-12-29 00:00:00 | REDLINED, RECEPT CIRCUITING SHALL BE | | | INDICATED AND SHOWN BEFORE ROUGH. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-05-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-17 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-17 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2006-05-17 00:00:00 | REVISION DATED 3/30/06 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-23 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-23 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-11 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-11 |
Time |
10:40 |
Sent To |
E |
|
| Notes |
| 2006-07-11 00:00:00 | SENT TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-16 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-16 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2006-04-25 00:00:00 | TO "COMM" BD#36 | | 2006-04-10 00:00:00 | WAITING FOR "COMM" BD--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-28 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-28 |
Time |
17:31 |
Sent To |
M |
|
| Notes |
| 2006-01-28 00:00:00 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-06 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-12-23 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | TO "BOB"#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-27 |
Time |
11:51 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-06-27 |
Time |
11:51 |
Sent To |
E |
|
| Notes |
| 2006-06-27 00:00:00 | REVISION TO MECHANICAL PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-11 |
Time |
09:31 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-11 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2006-05-11 00:00:00 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) SUPPLY AIR GRILLS NEED TO SHOW THE | | | CFM'S. PLEASE CORRECT. | | | | | | 2) IF AHU IS TO BE INCLOSED IN A SOFFIT | | | PLEASE SHOW HOW RETURN AIR WILL GET TO | | | AHU. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-31 |
Time |
15:29 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-01-31 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-28 |
Time |
14:25 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-12-28 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2005-12-28 00:00:00 | *** DENIED *** | | | 1) NEW REGISTER IN SECRATARY SPACE IS | | | NOT SIZED AND NOT SHOWING CFM'S.. | | | | | | 2) CFM'S. ARE NOT SHOWING AT ANY GRILLS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|