Plan Review Details - Permit 05120948
Plan Review Stops For Permit 05120948
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-05-23 Cont ID  
Sent By lursu Date 2006-05-23 Time 11:25 Rev Time 0.00
Received By lursu Date 2006-04-27 Time 08:52 Sent To  
Notes
2006-05-23 00:00:00THE NEW SITE ADDRESS FOR THE DEVELOPMENT
 IS 766 N ST WITH AN EXT #0001 "FOR BLDG
 1 CREATED.PERMIT ATTACHED TO BLDG 1.
2006-05-09 00:00:00MONTHLY UPDATES ARE NECESSARY TO ASSIGN
 THE SITE ADDRESS FOR THE PROJECT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-12 Cont ID  
Sent By mjacobs Date 2006-06-12 Time 08:58 Rev Time 0.00
Received By mjacobs Date 2006-05-25 Time 10:44 Sent To  
Notes
2006-05-25 00:00:001) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 2) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3) 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERMORMED IN A MANNER SO
 AS NOT TO ADVERSLY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER.THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORIC SURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGNCOMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED
 SITES.ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENET, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCELL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 4) WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
 A) WINDOWS FIXED AND OPERATABLE
 B)EXTERIOR DOORS SWINGING AND FIXED
 C)MULLIONS IF ANY
 D)ROOF ASSEMBLY
 E)TRUSS ANCHORS ETC.
 PRODUCTS WITH STATEWIDE APPROVAL
 ARE REQUIRED TO BE SUBMITTED WITH A
 COVER SHEET THAT LISTS THE PRODUCT
 IDENTITY NUMBER FROM THE STATE. IF THE
 PRODUCT DOES NOT HAVE STATEWIDE
 APPROVAL, SUBMIT AN APPLICATION FOR
 LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5) R802.10.1 TRUSS DESIGN DRAWINGS.
 TRUSS DESIGN DRAWINGS, PREPARED IN
 CONFORMANCE WITH SECTION R802.10.1 ,
 SHALL BE PROVIDED TO THE BUILDING
 OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. TRUSS DESIGN DRAWINGS
 SHALL INCLUDE, AT A MINIMUM, THE
 INFORMATION SPECIFIED BELOW. TRUSS
 DESIGN DRAWING SHALL BE PROVIDED WITH
 THE SHIPMENT OF TRUSSES DELIVERED TO THE
 JOBSITE.
  
 6) R903.4.1
 WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW
 WATER IS NOT PROVIDED, OVERFLOW SCUPPERS
 SHALL BE PLACED IN WALLS OR PARAPETS NOT
 LESS THAN 2 INCHES (51 MM) NOR MORE THAN
 4 INCHES (102 MM) ABOVE THE FINISHED
 ROOF COVERING AND SHALL BE LOCATED AS
 CLOSE AS PRACTICAL TO REQUIRED VERTICAL
 LEADERS OR DOWNSPOUTS OR WALL AND
 PARAPET SCUPPERS. AN OVERFLOW SCUPPER
 SHALL BE SIZED IN ACCORDANCE WITH THE
 FLORIDA BUILDING CODE, PLUMBING .
 SPECIFY CLEARLY THE SIZE OF THE ROOF
 DRAIN AND SCUPPERS.
  
 7) SHEET A-1. THE CLAEAR FLOOR SPACE
 CANNOT EXTEND INTO THE SHOWER. THE CLEAR
 FLOOR SPACE DIMENSIONS ARE TO BE APPLIED
 OR SUPERIMPOSED OVER A PLAN DURING THE
 DESIGN PROCESS TO DETERMINE IF THE SPACE
 REQUIREMENTS ARE BEING MET.
 FH.7.43/7.56. A 30"X48" CLEAR FLOOR
 SPACE MUST BE PROVIDED AT SHOWER
 STALLS,PARALLEL TO THE FIXTURE AND FLUSH
 WITH THE CONTROL WALL.
 ***RESPONSE NOTED, BUT TYPE "B" BATH
 DETAIL 6 ON SHT D3 DOES NOT COMPLY WITH
 CLEAR FLOOR SPACE REQUIREMENTS FOR THE
 SHOWER AS INDICATED. FH. 7.53 - 7.58
  
 8) ON SHEET D-1 DETAIL #2 SHOWS THE
 THIRD FLOOR BEING POURED INTO THE 2HR
 RATED WALL. EACH FLOOR SHALL BE
 INDEPENDANTLY ATTATCHED TO THE 2HR
 DEVIDING WALL.
  
 9) A DETAIL DRAWING OF THE FLOOR JOIST
 CONNECTION TO THE COMMON WALL IS
 REQUIRED SHOWING ALL MATERIALS WHICH
 WILL BE USED ,ALSO STATE THE LIVE AND
 DEAD LOADS OF EACH FLOOR AND THE SPACING
 OF THE FLOOR JOISTS.
  
  
 10) R324.1 SPRINKLER SYSTEM REQUIREMENTS
 FOR BUILDINGS THREE STORIES OR MORE IN
 HEIGHT. NFPA 101, AS REGARDING THE
 REQUIREMENTS FOR FIRE PROTECTION
 SPRINKLERS, IS APPLICABLE TO ALL
 MULTIPLE-FAMILY RESIDENTIAL BUILDINGS,
 WHETHER DESIGNATED AS TOWNHOUSES,
 CONDOMINIUMS, APARTMENT HOUSES,
 TENEMENTS, GARDEN APARTMENTS OR BY ANY
 OTHER NAME. THE ATTORNEY GENERAL HAS
 DETERMINED THAT FOR THE PURPOSE OF THE
 FIRE PROTECTION SPRINKLER REQUIREMENTS
 IN SECTION 553.895(2), FLORIDA STATUTES
 , TOWNHOUSES THAT ARE THREE OR MORE
 STORIES TALL AND CONSIST OF THREE OR
 MORE UNITS TOGETHER ARE MULTIPLE-FAMILY
 DWELLINGS. THEREFORE, THESE TYPES OF
 TOWNHOUSES ARE NOT EXEMPT. A SEPERATE
 PERMIT IS REQUIRED FOR THE SPRINKLER
 SYSTEM.
  
 11) R401.4 SOIL TESTS.
 IN AREAS LIKELY TO HAVE EXPANSIVE,
 COMPRESSIBLE, SHIFTING OR OTHER UNKNOWN
 SOIL CHARACTERISTICS, THE BUILDING
 OFFICIAL SHALL DETERMINE WHETHER TO
 REQUIRE A SOIL TEST TO DETERMINE THE
 SOIL ?S CHARACTERISTICS AT A PARTICULAR
 LOCATION. THIS TEST SHALL BE MADE BY AN
 APPROVED AGENCY USING AN APPROVED
 METHOD.
  
 12) SHEET D-1 SHOWS THE THIRD FLOOR AS
 PART OF THE 2 HOUR FIRE WALL. EACH
 INDIVIDUAL TOWNHOUSE SHALL BE
 STRUCTURALLY INDEPENDENT OF EACH OTHER.
 SEE R317.2.4 AND F.S.481.203 (7)(C).
  
 13) RULE 61G155-23.001(1) F.A.C.
 THE FLORIDA BOARD OF PROFESSIONAL
 ENGINEERS HAS CLEANED UP THE APPEARENCE
 OF THE SEAL BY ELIMINATING OBSOLETE
 CONTENT AND CHANGING THE WORD
 "CERTIFICATE" TO "LICENSE". A GRACE
 PERIOD RAN THROUGH DEC. 31,2005.
 SHEETS S-1-1 TO S-6
  
 14 ) 61G1-16.004FL. ADMIN. CODE.
 PLANS PREPARED BY A REGISTERED ARCHITECT
 SHALL INCLUDE A TITLE BLOCK WHICH MUST:
 - STATE THE FIRM NAME, ADDRESS AND
 TELEPHONE NUMBER
 - STATE THE FIRM LICENSE NUMBER
 - STATE PROJECT NAME OR IDENTIFICATION
 - STATE DATE PREPARED
 - INCLUDE AN ORIGINAL SIGNATURE AND
 DATED SEAL
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS. ALSO SEE
 61G15-23.002.
  
 15) WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A
 SPECIAL INSPECTOR AS REQUIRED BY S.
 553.79(5) FLORIDA STATUTES TO THE MIN-
 IMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 16) HI-LIGHT OR CIRCLE WHICH ROOF
 ASSEMBLY WILL BE USED FROM THE
 PACKAGE.SUBMIT THE PAGES WHICH STATE ALL
 THE MATERAIALS,THE SYSTEM TO BE USED AND
 THE LAST PAGE WITH THE GENERAL
 LIMITATIONS: WHEN THE ASSEMBLY IS
 CHOSEN, BE SURE TO READ THE LIMITATION
 AND NOTE WHAT IS REQUIRED. THE STATE
 COVER SHEETS ARE MISSING FORM ALL THE
 PRODUCT APPROVALS, SEE NOTE #4.
  
 17) FBC 13-103.1.2 BEFORE A BUILDING
 PERMIT CAN BE ISSUED, THE SUBMITTED
 ENERGY CODE COMPLIANCE FORMS SHALL BE
 SIGNED BY THE BUILDING OWNER, THE
 OWNER'S ARCHETECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-15 Cont ID  
Sent By mjacobs Date 2006-03-15 Time 16:58 Rev Time 0.00
Received By mjacobs Date 2006-03-11 Time 09:56 Sent To PC
Notes
2006-03-15 00:00:0005120948
  
 1) FL STATUTES. 713.13. NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK
 OF THE COURT BEFORE A PERMIT WILL BE
 ISSUED. NOTE: 713.13(2) IF THE WORK
 DESCRIBED IN THE NOTICE OF COMMENCEMENT
 IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE
 IS NULL & VOID.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) 109.3.10* IMPACT OF CONSTRUCTION. ALL
 CONSTRUCTION ACTIVITY REGULATED BY THIS
 CODE SHALL BE PERFORMED IN A MANNER SO
 AS NOT TO ADVERSELY IMPACT THE CONDITION
 OF ADJACENT PROPERTY, UNLESS SUCH
 ACTIVITY IS PERMITTED TO AFFECT SAID
 PROPERTY PURSUANT TO A CONSENT BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS &
 CONDITIONS AGREEABLE TO THE APPLICABLE
 PROPERTY OWNER. THIS INCLUDES BUT IS NOT
 LIMITED TO THE CONTROL OF DUST, NOISE,
 WATER OR DRAINAGE RUN-OFF, DEBRIS, AND
 THE STORAGE OF CONSTRUCTION MATERIALS.
 NEW CONSTRUCTION ACTIVITY SHALL NOT
 ADVERSELY IMPACT HISTORIC SURFACE WATER
 DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, & MAY REQUIRE SPECIAL
 DRAINAGE DESIGN COMPLYING WITH
 ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE PATTERNS OF THE AFFECTED
 SITES. ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCEL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALLY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 4) (2004 FBC) 106.1.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE &
 EXTENT OF THE WORK PROPOSED & SHOW IN
 DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, AND RULES AND
 REGULATIONS AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 5) FBC.1609.1.4 PROTECTION OF OPENINGS.
 IN WIND-BORNE DEBRIS REGIONS, EXTERIOR
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IN THE LOWER 60 FEET (18.3 M) IN
 BUILDINGS SHALL BE ASSUMED TO BE
 OPENINGS AND THE BALANCE OF GLAZED
 OPENINGS IN THE REST OF THE BUILDING
 SHALL BE ASSUMED TO BE ZERO UNLESS SUCH
 GLAZING THAT RECEIVES POSITIVE PRESSURE
 IS IMPACT RESISTANT OR PROTECTED WITH AN
 IMPACT RESISTANT COVERING MEETING THE
 REQUIREMENTS OF SSTD 12, ASTM E 1886 AND
 ASTM E 1996, OR MIAMI-DADE TAS 201, 202
 AND 203 REFERENCED THEREIN AS FOLLOWS:
 1.GLAZED OPENINGS LOCATED WITHIN 30
 FEET (9.1 M) OF GRADE SHALL MEET THE
 REQUIREMENTS OF THE LARGE MISSILE TEST.
 2.GLAZED OPENINGS LOCATED MORE THAN
 30 FEET (9.1 M) ABOVE GRADE SHALL MEET
 THE PROVISIONS OF THE SMALL MISSILE
 TEST.
  
 6) EGRESS WINDOWS (2ND/3RD FLOORS)
 PROVIDE THE MANUFACTURERS CUT SHEETS
 WITH NET CLEAR OPENING SIZES MINIMUM OF
 5.7 SQ FT.
 R310.1.1
  
 7)R310.4 THE TEMPORARY INSTALLATION OR
 CLOSURE OF STORM SHUTTERS, PANELS, AND
 OTHER APPROVED HURRICANE PROTECTION
 DEVICES SHALL BE PERMITTED ON EMERGENCY
 ESCAPE AND RESCUE OPENINGS DURING THE
 THREAT OF A STORM. SUCH DEVICES SHALL
 NOT BE REQUIRED TO COMPLY WITH THE
 OPERATIONAL CONSTRAINTS OF SECTION
 R310.1.4 . WHILE SUCH PROTECTION IS
 PROVIDED, AT LEAST ONE MEANS OF ESCAPE
 FROM THE DWELLING OR DWELLING UNIT SHALL
 BE PROVIDED. THE MEANS OF ESCAPE SHALL
 BE WITHIN THE FIRST FLOOR OF THE
 DWELLING OR DWELLING UNIT AND SHALL NOT
 BE LOCATED WITHIN A GARAGE. OCCUPANTS IN
 ANY PART OF THE DWELLING OR DWELLING
 UNIT SHALL BE ABLE TO ACCESS THE MEANS
 OF ESCAPE WITHOUT PASSING THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
  
 8) ) PROVIDE STORM PANEL INFORMATION
 INSTALLATION SCHEDULE AND KEY PLANWITH
 THE SPECIFIC ANCHORS & MOUNTING DETAILS
 FOR ALL NON-IMPACT GLAZING.
  
 9)2004 FL. BLD CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 LOADS SHALL BE SHOWN, REGARDLESS OF
 WHETHER WIND LOADS GOVERN
 THE DESIGN OF THE LATERAL-FORCE
 ?RESISTING SYSTEM OF THE BUILDING.
 1) - BASIC WIND SPEED, MPH
 2) - WIND IMPORTANCE FACTOR, & BUILDING
 CLASSIFICATION.
 3) - WIND EXPOSURE
 4) - INTERNAL PRESSURE COEFFICIENT.
 5 ) - COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 10): THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMMENDMENT TO FBC 106.3.3
 A) WINDOWS FIXED AND OPERATABLE
 B) EXTERIOR DOORS SWING AND FIXED
 C) MULLIONS IF ANY
 D) STORM SHUTTERS
 E) ROOF ASSEMBLY
 F) TRUSS ANCHORS,
 PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE
 REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL
 OR SITE SPECIFIC FORM PER RULE 9B-72.
 SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 11) MULTISTORY TOWNHOUSES ARE COVERED BY
 THE REQUIREMENTS OF FAIR HOUSING
 ACCESSIBILITY GUIDELINES IF THERE ARE
 FOUR OR MORE UNITS IN THE BUILDING AND
 THE BUILDING CONTAINS ONE OR MORE
 ELEVATORS. QUESTIONS AND ANSWERS ABOUT
 THE GUIDELINES, 59 FR 33362-33368, JUNE
 28, 1994, QUESTION 13 AND SEE
 WWW.FAIRHOUSIGFIRST.ORG/FAQ/TOWNHOUSES.H
  
 12) THE BATHROOM DETAIL ON SHEET D-3
 DOES NOT MATCH ANY BATHROOM DETAIL ON
 THE FLOOR PLANS. PLEASE CLARIFY. ALSO
 SHOW THE DETAIL DRAWING FOR GRAB
 BAR BACKING. SEE FHA. PAGE 6.4/6.5/6.12
  
 13)A 30X48? CLEAR FLOOR SPACE MUST BE
 PROVIDED AT SHOWER STALLS, PARALLEL TO
 THE FIXTURE AND FLUSH WITH THE CONTROL
 WALL. TOILET CANNOT BE IN THE CLEAR
 FLOOR SPACE. ALSO SHOW THE CLEAR FLOOR
 SPACE FOR ALL BATHROOM FIXTURES.
 SEE PAGES 7.43 ? 7.56.
  
 14) SHEET D-1 INDICATES THE 2ND AND 3RD
 BEING POURED AS PART OF THE 2HR RATED
 WALL.THE COMMON WALL FOR TOWNHOUSES
 SHALL BE CONTINUOUS FROM THE FOUNDATION
 TO THE UNDERSIDE OF THE ROOF SHEATHING,
 DECK OR SLAB AND SHALL EXTEND THE FULL
 LENGTH OF THE COMMON WALL INCLUDING
 WALLS EXTENDING THROUGH AND SEPARATING
 ATTACHED ACCESSORY STRUCTURES. R317.2.1.
 THIS SHEET NEEDS TO BE SEALED AND
 SIGNED. (D-1)
  
 15) A DETAIL DRAWING OF THE FLOOR
 CONNECTION TO THE COMMON WALL IS
 REQUIRED SHOWING ALL THE MATERIALS TO BE
 USED. ALSO STATE THE LIVE AND DEAD LOAD
 OF EACH FLOOR, AND THE SPACING OF THE
 TRUSSES. SUBMIT THE INFORMATION FOR THE
 FLOOR FROM AMERICAN FLOOR SYSTEM.
  
 16) R806.1 ENCLOSED ATTICS AND ENCLOSED
 RAFTER SPACES FORMED WHERE CEILINGS ARE
 APPLIED DIRECTLY TO THE ROOF RAFTERS
 SHALL HAVE CROSS VENTILATION.SHOW
 INFORMATION ON DRAWINGS. ALSO SEE FBC
 1203 FOR MORE INFORMATION
  
 17) FBC 2320.3.1.2 GROUPS R1, R2 AND R4
 OCCUPANCIES. IN FLOOR-CEILING ASSEMBLIES
 SEPARATING USABLE SPACES INTO TWO OR
 MORE APPROXIMATE AREAS WITH NO AREA
 GREATER THAN 500 SQUARE FEET (46.5 M 2
 ). DRAFTSTOPPING SHALL BE PROVIDED
 PARALLEL TO THE MAIN FRAMING MEMBERS IN
 THE FLOOR-CEILING ASSEMBLIES OF
 MULTIPLE-FAMILY DWELLINGS, MOTELS AND
 HOTELS ABOVE AND IN LINE WITH THE TENANT
 SEPARATION, WHEN TENANT SEPARATION WALLS
 DO NOT EXTEND TO THE FLOOR SHEATHING
 ABOVE.
  
 18) R324.1 SPRINKLER SYSTEM REQUIREMENTS
 FOR BUILDINGS THREE STORIES OR MORE IN
 HEIGHT. NFPA 101, AS REGARDING THE
 REQUIREMENTS FOR FIRE PROTECTION
 SPRINKLERS, IS APPLICABLE TO ALL
 MULTIPLE-FAMILY RESIDENTIAL BUILDINGS,
 WHETHER DESIGNATED AS TOWNHOUSES,
 CONDOMINIUMS, APARTMENT HOUSES,
 TENEMENTS, GARDEN APARTMENTS OR BY ANY
 OTHER NAME. THE ATTORNEY GENERAL HAS
 DETERMINED THAT FOR THE PURPOSE OF THE
 FIRE PROTECTION SPRINKLER REQUIREMENTS
 IN SECTION 553.895(2), FLORIDA STATUTES,
 TOWNHOUSES THAT ARE THREE OR MORE
 STORIES TALL AND CONSIST OF THREE OR
 MORE UNITS TOGETHER ARE MULTIPLE-FAMILY
 DWELLINGS.
  
 19) R613.6.2 WINDOW AND DOOR BUCKS.
 UNLESS OTHERWISE TESTED, BUCKS SHALL
 EXTEND BEYOND THE INTERIOR FACE OF THE
 WINDOW OR DOOR FRAME SUCH THAT FULL
 SUPPORT OF THE FRAME IS PROVIDED.
 SEE SHEET D-4 #5.
  
 20) SHEETS S-3 / S-3.1 DO NOT REFLECT
 THE SECOND FLOOR AS STATED ON THE
 DRAWING INDEX SHEET. THESE SHEETS
 REFLECT THE 3RD FLOOR. THE 2ND FLOOR
 STRUCTURAL PLANS ARE MISSING FROM THE
 PACKAGE. ADJUST THE SHEETS TO SHOW THE
 CORRECT FLOOR PLANS.
  
 21) SHEET A-9 REFERS TO SHEET (D-6 # 2),
 HOWEVER, THERE IS NO #2 DETAIL ON SHEET
 D-6. PLEASE MODIFY PLANS ACCORDINGLY TO
 REFLECT THE CORRECT DETAIL DRAWINGS.
 DETAIL DRAWINGS
 SHALL SHOW ALL DIMENSIONS ON THE
 DRAWINGS. WHAT IS THE WIDTH, LENGTH AND
 HEIGHT OF THE BALCONY? ALSO WHAT TYPE OF
 MATERIAL IS THE BRACKET UNDER THE
 BALCONY MADE OFF? SHOW THE ATTACHMENT
 DETAILS OF EACH OVERHANG AT THE
 BALCONIES.
  
 22) SHOULD THERE BE A SHEET 5-5 OR S-5?
 INDICATE ON THE STRUCTURAL SHEETS THE
 DETAILS SHOWN ON SHEETS 5-5 AND SHEET
 S-6.
  
 23) SUBMIT AN ABBREVIATION SHEET WITH
 THE MEANING OF ALL ABBREVIATIONS ON THE
 DRAWINGS.
  
 24) 11-4.6.2 LOCATION.
 ACCESSIBLE PARKING SPACES SERVING A
 PARTICULAR BUILDING SHALL BE LOCATED ON
 THE SHORTEST SAFELY ACCESSIBLE ROUTE OF
 TRAVEL FROM ADJACENT PARKING TO AN
 ACCESSIBLE ENTRANCE. IN PARKING
 FACILITIES THAT DO NOT SERVE A
 PARTICULAR BUILDING, ACCESSIBLE PARKING
 SHALL BE LOCATED ON THE SHORTEST
 ACCESSIBLE ROUTE OF TRAVEL TO AN
 ACCESSIBLE PEDESTRIAN ENTRANCE OF THE
 PARKING FACILITY. IN BUILDINGS WITH
 MULTIPLE ACCESSIBLE ENTRANCES WITH
 ADJACENT PARKING, ACCESSIBLE PARKING
 SPACES SHALL BE DISPERSED AND LOCATED
 CLOSEST TO THE ACCESSIBLE ENTRANCES.
 EACH PARKING SPACE MUST BE NO LESS THAN
 12 FEET (3658 MM) WIDE.
 (1) ALL SPACES MUST BE LOCATED ON AN
 ACCESSIBLE ROUTE NO LESS THAN 44 INCHES
 (1118 MM) WIDE SO THAT USERS WILL NOT BE
 COMPELLED TO WALK OR WHEEL BEHIND PARKED
 VEHICLES. SHOW THE ACCESSIBLE ROUTE TO
 BUILDING #1. SEE ADDITIONAL INFORMATION
 IN PACKAGE.
  
 25) R312.2 GUARD OPENING LIMITATIONS.
 REQUIRED GUARDS ON OPEN SIDES OF
 STAIRWAYS, RAISED FLOOR AREAS, BALCONIES
 AND PORCHES SHALL HAVE INTERMEDIATE
 RAILS OR ORNAMENTAL CLOSURES WHICH DO
 NOT ALLOW PASSAGE OF A SPHERE 4 INCHES
 (102MM) OR MORE IN DIAMETER.
  
 26) R311.5.2 HEADROOM.
 THE MINIMUM HEADROOM IN ALL PARTS OF THE
 STAIRWAY SHALL NOT BE LESS THAN 6 FEET 8
 INCHES (2036 MM) MEASURED VERTICALLY
 FROM THE SLOPED PLANE ADJOINING THE
 TREAD NOSING OR FROM THE FLOOR SURFACE
 OF THE LANDING OR PLATFORM. SEE PAGES
 A-9 / A-10.
  
 27) WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST
 FOR RESIDENT BUILDINGS A SPECIAL
 INSPECTOR AS REQUIRED BY S. 553.79(5)
 FLORIDA STATUTES TO THE MIN- IMUM
 INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
 SEE APPLICATION IN PACKAGE.
  
 28) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 MYRON JACOBS
 BUILDING PLANS EXAMINER
 TEL: (561)805-6726
  
  
  
2006-03-11 00:00:00 
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-11 Cont ID  
Sent By dpalmer Date 2006-06-11 Time 16: Rev Time 0.00
Received By dpalmer Date 2006-06-11 Time 15:40 Sent To  
Notes
2006-06-11 00:00:00IN ELEC FOR REVIEW.
 ********** UNSAT 2ND REVIEW ***********
  
 ** PLEASE SEE PLANS ARE STILL ONLY BEING
 SUBMITTED FOR "PLAN REVIEW " AND NOT FOR
 PERMIT.
 SOME COMMENTS ARE FROM PREVIOUS REVIEW
 AND SOME ARE NEW.
  
 PLEASE SEE NOTES BELOW ARE TAKEN
 DIRECTLY FROM PREVIOUS REVIEW AND NEW
 NOTES ARE ADDED AT THE END OF PREVIOUS
 NOTES.
  
 ********* UNSAT *************
  
 1)NOTE: NOTE #1 SAME, PLEASE SEE AS ONLY
 SUBMITTED FOR PLAN REVIEW, IT IS STILL
 NOT KNOW, IF EACH UNIT WILL BE A LEGAL
 TOWNHOUSE WITH PROPERTY LINES SEPARATING
 UNITS ETC. ONLY IF THIS IS THE CASE WILL
 ONE SERVICE BE GRANTED FOR EACH
 TOWNHOUSE. IF THIS IS ONE BUILDING UNDER
 ONE LEGAL ADDRESSAND PERMITTED UNDER
 ONE PERMIT, THEN ONLY ONE SERVICE WILL
 BE GRANTED. AS PLANS ARE NOT SUBMITTED
 FOR PERMIT. THIS COMMENT SHALL REMAIN
 AND PLANS STILL MAY NEED TO BE REVISED
 AT A LATER DATE.
  
 ** PREVIOUS NOTE **
 PLANS SUBMITTED FOR PLAN REVIEW
 UNDER ONE SINGLE MULTI-FAMILY BLDG,
 HOWEVER ELECTRICAL SERVICES SEEM TO
 INDICATE THE UNIT WILL BE A FEE-SIMPLE
 "TOWNHOUSE". ?? COULD NOT LOCATE ANY
 PROPERTY LINES ON SITE PLAN OR ANY
 INDICATTION OF SUCH. PLEASE SEE 230.2,
 ONLY ONE ELECTRICAL SERVICE WILL BE
 PERMITTED. PLEASE ALSO SEE OTHER
 COMMENTS IF INDEED EACH UNIT WILL BE
 SEPARATED BY PROPERTY LINES AND A 4HR
 FIRE WALL. PLEASE SEE 2004 FBC
 DEFINITIONS FOR "FIREWALL".
 PLEASE REVISE ELECTRICAL SERVICE PLANS
 AS NEEDED DEPENDING ON WHAT TYPE FO
 BLDG.
 ** PLEASE KNOW, IF BLDG(S) DO BECOME
 INDIVIDUALLY OWNED , WITH SEPARATE PCN
 NUMBERS ETC, THEN EACH UNIT WOULD BE A
 SEPARATEPERMIT APPLICATION WITH
 SEPARATE PLANS AND FEES.
 THIS WOULD AFFECT COMMENT #3 FOR THE
 DESIGN PROFESSIONAL REQUIREMENT.
 ** PLEASE SEE NOTE #4 FOR ADDRESSING OF
 BLDG.
  
 2)NOTE: OK.
  
 3)NOTE: NOTE #3 ? IT IS NOT KNOWN AT
 THIS TIME IF ARCHITECT MAY SIGN, DATE
 AND SEAL PLANS. IF PROJECT IS ONE
 BUILDING WITH ONE SERVICE THEN PLANS
 WILL BE REQUIRED TO BE SIGNED , DATED
 AND SEALED BY A PE.
  
 ** PREVIOUS NOTE **
 PLEASE SEE FS 471.003(2)(H)
 WHICH REQUIRES THE ELECTRICAL PLANS TO
 BE DONE BY ANY ENGINEER.
 PLEASE ADJUST AS NESSESARY.
  
 4)NOTE: NOTE #4 NO, PLEASE SEE ADDRESS
 ON PLANS/TITLE BLOCKS STILL INDICATE
 1200 LAKE AVE.PLEASE SEE THE ADDRESS
 ASSIGNED FOR THE BUILDING IS 766 N ST.
 PLEASE SEE IF THESE UNITS ARE DONE UNDER
 SEPARATE PERMITS AS LEGAL "TOWNHOUSE",
 THEN THERE WILL BELEGAL PROPERTY
 ADDRESS FOR EACH.
  
 ** PREVIOUS NOTE**
 PLEASE SEE NOTES FROM ZONING AND
 ADDRESSING AS BLDG SEEM TO CONTAIN THE
 SMALL PORTION OF THE BLDG ON LAKE AVE
 WHICH WOULD BE THE ADDRESS AS LISTED ON
 PLANS. PLEASE SEE COMMENT #1, IF BLDG
 CHNAGES, THEN SEPARATE ADDRESSES WOULD
 BE APPLIED AND TITLE BLOCK WOULD BE
 ADJUSTED.
  
 5)NOTE: NOTE #5 NO, PLEASE SEE THIS WAS
 DONE ON COVER SHEET, HOWEVER ELECTRICAL
 PLANS MENTIONS THE LATEST CODES, AND THE
 LATEST CODES WHICH ARE OUT, ARE NOT
 ADOPTED YET. THEREFORE ELECTRICAL PLANS
 SHALL ALSO INDICATE THE CODES AS NOTED.
 2002 NFPA-72, 2002 NFPA-70
  
 ** PREVIOUS NOTE **
 PLEASE SEE PLANS SHALL INDICATE
 THE CURRENT CODES IN EFFECT. PLEASE SEE
 THIS HAS NOT BEEN SUBMITTED FOR PERMIT
 AS OF YET AND THEREFORE DEPENDING ON
 WHEN THAT HAPPENS, THE 2005 NEC SHOULD
 BE ADOPTED IN THE MONTHS TO COME.
 PLEASE SEE THE CURRENT CODE IS THE 2004
 FBC. PLEASE SEE PLANS SHALL REFERENCE
 THE CURRENT NFPA-101 2003, NFPA-72 2002
 , AND 2002 NFPA-70 (NEC). PLEASE SEE
 REDLINED LOCATIONS ON THE PLANS WHERE
 THERE ARE REFERENCES TO THE "1996"
 AND "1999" NEC. PLEASE KNOW, AS OF JULY
 1ST, 2003 THE STATE OF FLORIDA ADOPTED
 THE 2002 NEC.
 PLEASE ADJUST LOCATIONS AND REQUIREMENTS
 AS NEEDED.
 PLEASE OTHER COMMENTS AFFECT BY THE CODE
 CHANGES BELOW.
  
 6)NOTE: OK
  
 7)NOTE: OK.
  
 8)NOTE: OK
  
 9)NOTE: NOTE #9, PLEASE SEE THE
 EQUIPMENT GROUNDING CONDUCTOR WAS
 REMOVED FROM THE METER TO THE MAIN AS
 NOTED ON PREVIOUS REVIEW, HOWEVER SEE
 NOW THE EQUIPMENT GROUNDING CONDUCTOR
 HAS NOW ALSO BEEN REMOVED AFTER THE
 MAIN??
 250.24B, 250.110,250.122
  
 ** PREVIOUS NOTE **
 PLEASE SEE IF PLANS DO BECOME
 INDIVIDUAL UNITS AND SEPARATE SERVICES
 ARE PERMITTED, PLEASE SEE RISER SHOWS AN
 "EQUIPMENT GROUNDING CONDUCTOR" FROM THE
 METER TO THE FIRST MEANS OF DISCONNECT.
 PLEASE SEE 250.6, AS THE EQUIPMENT
 GROUNDING CONDUCTOR IS ONLY INSTALLED
 AFTER THE FIRST MEANS OF DISCONNECT.
  
 10)NOTE:NOTE #10 NO, PLEASE SEE ONLY A
 PARTIAL NOTE WAS ADDED WITH RESPECT TO
 THE SD'S BEING LOCATED 3' FROM HVAC
 DIFFUSERS. PLEASE SEE THE NFPA BELOW, AS
 IT ALSO REQUIRES SD'S TO BE LCOATED 3'
 FROM KITCHEN AND BATH DOORS, AND 20'
 FROM ALL COOKING APPLIANCES WITH
 EXCEPTIONS. IF USING EXCEPTION, THEN
 PLANS SHALL INDICATE THE TYPE OF SD TO
 BE INSTALLED.
  
 ** PREVIOUS NOTE **
 PLEASE PROVIDE A NOTE ON PLANS
 WITH REFERENCE TO THE MIN CLEARNECES
 REQUIRED FOR SD'S AND PLACEMENT PER
 NFPA-72 2002 11.8.3.5
  
 11)NOTE: OK
  
 12)NOTE:NOTE #12, PLEASE SEE LOCATION
 OF CU IS SHOWN ON BALCONY OF 2ND FLR ,
 HOWEVER MIN CLEARENCS ARE NOT SHOWN PER
 110.26. PLEASE ALSO SEE MECHANICAL
 NOTES.
  
 ** PREVIOUS NOTE **
 PLEASE CONFIRM A/C CU LOCATIONS, AS
 THESE APPEAR TO BE LOCATED IN AN AREA ON
 2N FLR BALCONY? THIS ARE APPEARS MAYBE
 TO BE ENCLOSED?
  
 13)NOTE: OK.
  
 14)NOTE: OK.
  
 15)NOTE: OK.
  
 16)NOTE: NOTE# 16, NO, THIS IS NOT
 SETTLED AS OF YET. PLEASE SEE PLANS DO
 NOT INDICATE THE MAIN NEXT TO METER. (IF
 PERMITTED).
  
 ** PREVIOUS NOTE**
 PLEASE BE SURE TO CORRELATE
 PLANS WITH WHAT TYPE OF SERVICE IS GOING
 TO BE INSTALLED, PLEASE BE SURE
 EQUIPMENT(METER, MAINS ETC) ARE SHOWN ON
 PLANS AS WELL AS RISER.
 215.5
  
 17)NOTE: OK. AP WAS LOCATE DON BUILDING
 - 1 PLANS.
  
 ** PREVIOUS NOTE **
 PLEASE SEE WHIRLPOOL TUB IS
 LISTED AS OPTIONAL ON PANEL SCHEDULE
 ALONG WITH ALARM PANEL. PLEASE SEE THESE
 LOCATIONS FOR DEVICES NEED TO BE SHOWN
 ON PLASN FOR REVIEW. ACCESS PANEL FOR
 GFI AND LOCATION OF POSSISBLE FUTURE
 ALARAM PANEL NEEDS TO BE VERIFIED.
 ** PLEASE KNOW, ANY ELECTRICAL DEVICES
 ETC SHOWN AS "OPTIONAL" ON PLANS SHALL
 BE REVISED AND SUBMITTED FOR REVIEW AND
 TO BE ON JOBSITE BEFORE ROUGH**
  
 18)NOTE: OK.
  
 19)NOTE:NOTE #19 NO, UNCLEAR AT THIS
 TIME AS PLANS ARE STILL BEING SUBMITTED
 BY THE ARCHITECT WHICH A LETTER COULD
 NOT BE LOCATED IN PLANS AND PAPERWORK
 SUBMITTED.
 IF PLANS ARE DONE BY THE ARCH, THIS LTR
 SHLL BE PROPERLY NOTORIZED PER FS
 117.05.
  
 ** PREVIOUS NOTE **
 PLEASE SEE IF UNITS DO COME IN
 AS INDIVIDUAL AND ARE DONE BY THE
 ARCHITECT, PLEASE PROVIDE A SIGNED,
 DATED AND SEALED LETTER FOR VERIFICATION
 OF LEGAL SIGNATURE AS PLANS APPEAR TO BE
 INITIALS.
  
 ************************************
 NEW NOTES
  
 20) NOTE: PLEASE SEE THAT A TYPE WRITTEN
 RESPONSE FROM DESIGN TEAM WILL HELP IN
 THE REVIEW PROCESS WHICH WILL RESPOND TO
 EACH COMMENT INDIVIDUALLY.
  
 21) NOTE: PLEASE SUBMIT TEH AIC RATINGS
 FOR ALL SERVICE EQUIPMENT.
 110.9, 215.5
 THIS WAS ON PREVOUS PLANS BUT HAS NOW
 BEEN REMOVED. PLEASE KNOW, DEPENDING ON
 THE PERMITTING AND SERVICE WHICH WILL BE
 PERMITTED THE AIC RATINGS AND EQUIPMENT
 MAY CHANGE.
  
 22) NOTE: PLEASE SEE NOTES FROM BUILDING
 REVIEWER FOR MISSING INFORMATION FOR THE
 "S" SHEETS PER FAC 61G15-23.002, FS
 471.023
 MISSING CERTIFICATE OF AUTHORIZATION
 NUMBER AND THE PRINTED NAME AND LICENSE
 NUMBER OF ENGINEER ON TITLE BLOCK.
  
 23) NOTE: PLEASE SEE PANEL SCHEDULE
 SHALL BE SPECIFIC FOR ALL CIRCUITING.
 PLEASE SEE RECEPTS, AND LIGHTING
 CIRCUITS SHALL INDICATE ROOMS OR AREAS
 IN WHICH THEY ARE FEEDING.IE: BEDRM #3
 RECEPTS, KITCHEN LT ETC.
 **IT IS KNOW THAT DURING CONSTRUCTION,
 THESE WILL MOSTLY CHANGE AND MAY NEED TO
 BE REVISED AT A LATER DATE, HOWEVER MUST
 BE SPECIFIC AT THIS TIME.
  
 24) NOTE: PLEASE SEE A SD MAY BE
 REQUIRED AT 2ND LEVEL IN BUILDING ONE IN
 THE IMEDIATE VICINIY OF THE STAIRS, THIS
 IS REDLINED ON ONE SET AT LOCATION BUT
 IF NOT ADDED TO PLANS THE LOCATION SHALL
 BE VERIFIED IN FIELD.
 NFPA-72 11.5.1.1
  
 ** PLEASE SEE ANY OTHER COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ** IMPORTANT**
 ** PLEASE BE SURE TO REMOVE ALL
 OLD/VOIDED SHEETS FROM SETS AND ONLY
 INSERT NEW REVISED SHEETS INTO SETS FOR
 REVIEW AND STAMPING.
 ONE COPY OF OLD SHEETS SHOULD BE
 SUBMITTED FOR REFERENCE ONLY.
  
 ** PLEASE SEE BLDG COMMENTS WITH RESPECT
 TO PRODUCT APPROVALS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-01-25 Cont ID  
Sent By dpalmer Date 2006-01-25 Time 10:45 Rev Time 0.00
Received By dpalmer Date 2006-01-24 Time 18:49 Sent To  
Notes
2006-01-25 00:00:00REVIEW
 ********* UNSAT *************
  
 ***************************************
 PLEASE KNOW, PLANS HAVE ONLY BEEN
 SUBMITTED FOR "PLAN REVIEW " AND NOT FOR
 PERMIT. PLEASE ALSO KNOW THE CUT-OFF
 DATE FOR THE PALM BEACH COUNTY IMPACT
 FEE INCREASE WAS JAN 12TH, 2006. ONLY
 "PERMIT APPLICATIONS WITH ALL FEES PAID
 BEFORE 5PM ON JAN 12TH WOULD BE UNDER
 THE OLD FEE SCHEDULE.
 *************************************
  
  
 1)NOTE: PLANS SUBMITTED FOR PLAN REVIEW
 UNDER ONE SINGLE MULTI-FAMILY BLDG,
 HOWEVER ELECTRICAL SERVICES SEEM TO
 INDICATE THE UNIT WILL BE A FEE-SIMPLE
 "TOWNHOUSE". ?? COULD NOT LOCATE ANY
 PROPERTY LINES ON SITE PLAN OR ANY
 INDICATTION OF SUCH. PLEASE SEE 230.2,
 ONLY ONE ELECTRICAL SERVICE WILL BE
 PERMITTED. PLEASE ALSO SEE OTHER
 COMMENTS IF INDEED EACH UNIT WILL BE
 SEPARATED BY PROPERTY LINES AND A 4HR
 FIRE WALL. PLEASE SEE 2004 FBC
 DEFINITIONS FOR "FIREWALL".
 PLEASE REVISE ELECTRICAL SERVICE PLANS
 AS NEEDED DEPENDING ON WHAT TYPE FO
 BLDG.
 ** PLEASE KNOW, IF BLDG(S) DO BECOME
 INDIVIDUALLY OWNED , WITH SEPARATE PCN
 NUMBERS ETC, THEN EACH UNIT WOULD BE A
 SEPARATEPERMIT APPLICATION WITH
 SEPARATE PLANS AND FEES.
 THIS WOULD AFFECT COMMENT #3 FOR THE
 DESIGN PROFESSIONAL REQUIREMENT.
 ** PLEASE SEE NOTE #4 FOR ADDRESSING OF
 BLDG.
  
 2)NOTE: PLEASE SEE MISSING LICENSE
 INFORMATION ON TITLE BLCOKS FOR
 ARCHITECTUAL FIRM AS SHOWN. PLEASE SEE
 FLORIDA ADMINISTRATIVE CODE 61G1-16.004
 AND FS 481.219 WHICH REQUIRES THE
 CERTIFICATE OF AUTHORIZATION NUMEBR ON
 SAID TITLE BLOCK.
 PLEASE KNOW THIS IS REQUIRED FOR ALL
 SHEETS AND FOR ALL TRADES WHETHER OR NOT
 COMMET IS MADE BY OTHER REVIEWER(S).
 PLEASE SEE NEXT COMMENT AS THIS WILL
 AFFECT ELECTRICAL SHEETS.
  
 3)NOTE: PLEASE SEE FS 471.003(2)(H)
 WHICH REQUIRES THE ELECTRICAL PLANS TO
 BE DONE BY ANY ENGINEER.
 PLEASE ADJUST AS NESSESARY.
  
 4)NOTE: PLEASE SEE NOTES FROM ZONING AND
 ADDRESSING AS BLDG SEEM TO CONTAIN THE
 SMALL PORTION OF THE BLDG ON LAKE AVE
 WHICH WOULD BE THE ADDRESS AS LISTED ON
 PLANS. PLEASE SEE COMMENT #1, IF BLDG
 CHNAGES, THEN SEPARATE ADDRESSES WOULD
 BE APPLIED AND TITLE BLOCK WOULD BE
 ADJUSTED.
  
 5)NOTE: PLEASE SEE PLANS SHALL INDICATE
 THE CURRENT CODES IN EFFECT. PLEASE SEE
 THIS HAS NOT BEEN SUBMITTED FOR PERMIT
 AS OF YET AND THEREFORE DEPENDING ON
 WHEN THAT HAPPENS, THE 2005 NEC SHOULD
 BE ADOPTED IN THE MONTHS TO COME.
 PLEASE SEE THE CURRENT CODE IS THE 2004
 FBC. PLEASE SEE PLANS SHALL REFERENCE
 THE CURRENT NFPA-101 2003, NFPA-72 2002
 , AND 2002 NFPA-70 (NEC). PLEASE SEE
 REDLINED LOCATIONS ON THE PLANS WHERE
 THERE ARE REFERENCES TO THE "1996"
 AND "1999" NEC. PLEASE KNOW, AS OF JULY
 1ST, 2003 THE STATE OF FLORIDA ADOPTED
 THE 2002 NEC.
 PLEASE ADJUST LOCATIONS AND REQUIREMENTS
 AS NEEDED.
 PLEASE OTHER COMMENTS AFFECT BY THE CODE
 CHANGES BELOW.
  
 6)NOTE: PLEASE INDICATE ALL CIRCUTING ON
 PLANS AND CORRELATE WITH THE SUBMITTED
 PANEL SCHEDULES.
  
 7)NOTE: PLEASE SEE MISSING FOOTER STEEL
 TO BE PART OF THE GROUNDING ELECTRODE
 SYSTEM AS REQUIRED PER 250.50. PLANS REF
 250.83C(1996).
  
 8)NOTE: PLEASE LIST THE REQUIREDARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE PER 210.12 (2002) PLEASE SEE
 SD'S ARE BEING SHOWN AS CIRCUITED TO THE
 BATH LIGHTING CIRCUIT ON PANEL SCHEDULE,
 THIS IS OK, HOWEVER PLEASE KNOW ARC
 FAULT BRKR WOULD THEN BE REQUIRED.
 SD'S MAY BE CIRCUTED TO A BEDRM CIRCUIT.
  
 9)NOTE: PLEASE SEE IF PLANS DO BECOME
 INDIVIDUAL UNITS AND SEPARATE SERVICES
 ARE PERMITTED, PLEASE SEE RISER SHOWS AN
 "EQUIPMENT GROUNDING CONDUCTOR" FROM THE
 METER TO THE FIRST MEANS OF DISCONNECT.
 PLEASE SEE 250.6, AS THE EQUIPMENT
 GROUNDING CONDUCTOR IS ONLY INSTALLED
 AFTER THE FIRST MEANS OF DISCONNECT.
  
 10)NOTE: PLEASE PROVIDE A NOTE ON PLANS
 WITH REFERENCE TO THE MIN CLEARNECES
 REQUIRED FOR SD'S AND PLACEMENT PER
 NFPA-72 2002 11.8.3.5
  
 11)NOTE: PLEASE SEE REDLINED PLANS FOR
 MISSINF RECEPTS PER 210.52 FOR 2' OR
 MORE OF WALL SPACE.
  
 12)NOTE: PLEASE CONFIRM A/C CU
 LOCATIONS, AS THESE APPEAR TO BE LOCATED
 IN AN AREA ON 2N FLR BALCONY? THIS ARE
 APPEARS MAYBE TO BE ENCLOSED?
  
 13)NOTE: PLEASE SEE MISSING LT AT ENTRY
 REQUIRED PER 210.70,LS 101 7.8.
  
 14)NOTE: PLEASE SEE RECEPTS LOCATED IN
 LAUNDRY ROOM OTHER THAN WASHER, ARE
 REQUIRED TO BE GFI PER 210.8A
  
 15)NOTE: PLEASE SEE MISSING ELECTRICAL
 DEVICES FOR WASHER AND DRYER ON UNIT BL.
 215.5
  
 16)NOTE: PLEASE BE SURE TO CORRELATE
 PLANS WITH WHAT TYPE OF SERVICE IS GOING
 TO BE INSTALLED, PLEASE BE SURE
 EQUIPMENT(METER, MAINS ETC) ARE SHOWN ON
 PLANS AS WELL AS RISER.
 215.5
  
 17)NOTE: PLEASE SEE WHIRLPOOL TUB IS
 LISTED AS OPTIONAL ON PANEL SCHEDULE
 ALONG WITH ALARM PANEL. PLEASE SEE THESE
 LOCATIONS FOR DEVICES NEED TO BE SHOWN
 ON PLASN FOR REVIEW. ACCESS PANEL FOR
 GFI AND LOCATION OF POSSISBLE FUTURE
 ALARAM PANEL NEEDS TO BE VERIFIED.
 ** PLEASE KNOW, ANY ELECTRICAL DEVICES
 ETC SHOWN AS "OPTIONAL" ON PLANS SHALL
 BE REVISED AND SUBMITTED FOR REVIEW AND
 TO BE ON JOBSITE BEFORE ROUGH**
  
 18)NOTE: PLEASE SEE UNIT "BL", WHICH
 APPEARS TO SHOW ELECTRICAL FOR ELEVATOR
 UNDER STAIRS WITH NO ACCESS ETC.
 110.26 , 210.70
  
 19)NOTE: PLEASE SEE IF UNITS DO COME IN
 AS INDIVIDUAL AND ARE DONE BY THE
 ARCHITECT, PLEASE PROVIDE A SIGNED,
 DATED AND SEALED LETTER FOR VERIFICATION
 OF LEGAL SIGNATURE AS PLANS APPEAR TO BE
  
  
 ** PLEASE SEE ANY OTHER COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ** PLEASE BE SURE TO REMOVE ALL
 OLD/VOIDED SHEETS FROM SETS AND ONLY
 INSERT NEW REVISED SHEETS INTO SETS FOR
 REVIEW AND STAMPING.
 ONE COPY OF OLD SHEETS SHOULD BE
 SUBMITTED FOR REFERENCE ONLY.
  
 ** PLEASE SEE BLDG COMMENTS WITH RESPECT
 TO PRODUCT APPROVALS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
2006-01-24 00:00:00IN ELEC FOR REVIEW, PLAN REVIEW IN
 PROGRESS.
 PLANS WILL BE UNSAT,NOTES TO FOLLOW.

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2006-08-25 Cont ID  
Sent By rchokshi Date 2006-08-25 Time 13:44 Rev Time 0.00
Received By rchokshi Date 2006-08-25 Time 13:44 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2006-08-01 Cont ID  
Sent By rchokshi Date 2006-08-01 Time 13:14 Rev Time 0.00
Received By rchokshi Date 2006-08-01 Time 13:00 Sent To  
Notes
2006-08-01 00:00:00FAILED FOR FOLLOWING REASONS:
  
 CIVIL WATER SEWER PLANS MUST BE
 SUBMITTED TO ENGINEERING SERVICES FOR
 UTILITY REVIEW (45THSTREET MANNY G.&
 DEAN L.)
  
 PLEASE SUBMIT STORM WATER CAL.,INCLUDING
 PERVIOUS,IMPERVIOUS CAL., RUNOFF CAL.,
 GEOTECH ENG REPORT, DETAIL OF CONTROL
 STRUCTURES,ETC.
  
 ALL DRIVEWAYS, SIDE WALKS,PARKING ADA
 ETC.,MUST SAY ON DRAWINGS & MEET CITY OF
 WPB DEATAIS, REQUIREMENTS ETC.,
  
 RASIK CHOKSHI 805-6723

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-02-10 Cont ID  
Sent By mamini Date 2006-02-10 Time 09:13 Rev Time 1.00
Received By mamini Date 2006-02-10 Time 09:13 Sent To  
Notes
2006-02-10 00:00:00FAILED:
  
 1. PLEASE PROVIDE CIVIL/ SITE PLAN FOR
 OUR REVIEW AND APPROVAL, NOTE THAT CIVIL
 PLANS MUST BE SUBMITTED ALSO TO
 ENGINEERING SERVICES FOR APPROVAL OF ALL
 THE CONNECTIONS TO THE CITY SERVICES,
 ATT;MANNY GONZALEZ, 494-1085.
 2. PLEASE SUBMIT STORM WATER CALCULATION
 FOR THE ENTIRE SITE, INCLUDING PERVIOUS,
 IMPERVIOUS AND BUILDING AREA, COPY OF
 THE SFWMD PERMIT MUST ALSO BE SUBMITTED.
 3. POLLUTION PREVENTION PLAN MUST BE
 INCLUDED IN CIVIL PLANS.
  
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-06-16 Cont ID  
Sent By mwennerg Date 2006-06-16 Time 14:34 Rev Time 0.00
Received By mwennerg Date 2006-06-16 Time 14:34 Sent To  
Notes
2006-06-16 00:00:00***DENIED***
  
 1) ALL FIRE NEW FIRE HYDRANTS SHALL BE
 WET AND OPERATIONAL PRIOR TO, DURING AND
 AFTER CONSTRUCTION.
  
 2) OK
  
 3) OK
  
 4) PLEASE CALL OUT DISTANCE ON DRAWINGS.
  
  
 5) OK
  
 6) OK
  
 7) OK
  
 8) OK
  
 9) PLEASE INCLUDE FIRE SPRINKLER PLANS
 TO SHOW LAYOUT. SEPARATE SHOP DRAWINGS
 AND PERMIT WILL BE REQUIRED PRIOR TO
 INSTALLATION OF FIRE SPRINKLER SYSTEM.
  
 10) OK
  
 11) OK
  
 12) UL NUMBERS WERE NOT FOUND ON PLANS.
  
 13) OK
  
 14) PLEASE PROVIDE MORE DETAILS ON FP
 PLANS.
  
 15) DOUBLE CHECK DETECTOR ASSEMBLY SHALL
 BE ELECTRONICALLY SUPERVISED, AND
 SECURED WITH LOCK AND CHAIN.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-01-24 Cont ID  
Sent By mcarsill Date 2006-01-24 Time 12:41 Rev Time 0.00
Received By mcarsill Date 2006-01-24 Time 12:06 Sent To  
Notes
2006-01-24 00:00:001. SITE PLAN DOES NOT ILLUSTRATE NEW OR
 EXISTING FIRE HYDRANTS. PLEASE DISPLAY
 ALL FIRE HYDRANTS FOR THE PROPOSED
 DEVELOPMENT.
  
 2. ALL BUILDINGS THREE OR MORE STORIES
 REGARDLESS OF OCCUPANCY TYPE ARE
 REQUIRED TO BE FIRE SPRINKLER PROTECTED
 IN ACCORDANCE WITH FS 553.895 (2).
  
 3. ALL CONSTRUCTION, RENOVATION, AND
 DEMOLITION TO COMPLY WITH NFPA 241.
  
 4. FIRE SPRINKLER CONENCTIONS SHALL BE
 LOCATED NO FARTHER THAN 150 FEET FROM A
 FIRE HYDRANT.
  
 5. PLEASE PROVIDE PRSCRIPTIVE STRENGTH
 REQUIREMENTS FOR ALL HANDRAILS AND
 GUARDRAILS.
  
 6. BUILDING ADDRESSES ARE REQUIRED ON
 PROPER ELEVATIONS. A MINIMUM OF AT LEAST
 6" HIGH NUMBERS ARE REQUIRED.
  
 7. PORTABLE FIRE EXTINGUISHERS ARE SHOWN
 ON THE DRAWINGS. MORE DETAILS NEEDED ON
 THE TYPE AND FIRE RATINGS.
  
 8. THE REQUIRED FIRE SPRINKLER SYSTEM
 SHALL BE MONITORED BY A UL LISTED
 CENTRAL STATION APPROVED FOR CENTRAL
 STATION SERVICE.
  
 9. NO FIRE SPRINKLER SYSTEM DRAWINGS OR
 HYDRAULIC CALCULATIONS PROVIDED WITH
 PLANS.
  
 10. ALL REQUIRED SMOKE DETECTORS SHALL
 BE LOCATED AT LEAST THREE FEET FROM AIR
 CONDITIONER DIFFUSERS.
  
 11. PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATIONS FOR WALLS AND CEILINGS.
  
 12. PLEASE PROVIDE UL NUMBERS FOR THE
 TWO HOUR PARTY WALLS THAT ARE SHOWN.
  
 13. PLEASE CALL OUT ANY FENCE LOCATIONS
 ON THE SITE PLAN. A FENCE DETAIL IS
 OBSERVED ON PAGE SP-1 BUT IT IS NOT
 CALLED OUT ON THE SITE PLAN.
  
 14. PLEASE INDICATE HOW THE FIRE
 SPRINKLER SYSTEM BULK-MAIN IS TO BE RUN
 TO PROVIDE FIRE SPRINKLER PROTECTION.
 DESIGN ISSUES RESULT IF NOT PROPERTY
 CONSIDERED.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
  
 804-4709

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 08:40 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 08:40 Sent To  
Notes
2006-05-22 00:00:00TO "COMM" BD#63
2006-04-27 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-03-15 Time   Rev Time 0.00
Received By adarroug Date 2005-12-22 Time 10:21 Sent To  
Notes
2006-01-24 00:00:00TO "COMM" BD#33
2005-12-22 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-06-30 Cont ID  
Sent By pkrauss Date 2006-06-30 Time 10:20 Rev Time 0.00
Received By pkrauss Date 2006-06-29 Time 12:57 Sent To  
Notes
2006-06-30 00:00:00DENIED:2004 FLORIDA BUILDING CODE
  
 RESPONSE TO COMMENTS DATED 2-6-06 BY
 HAROLD MOSER.
  
 COMMENT 1 - OK
 COMMENT 2 - OK
 COMMENT 3 - OK
 COMMENT 4 - OK
 COMMENT 5 - PLEASE NOTE, SHOULD THE A/C
 UNIT HAVE THE CAPACITY TO PRODUCE MORE
 THAN 2,000 CFM, A DUCT SMOKE DETECTOR
 WITH AUDIBLE/VISUAL NOTIFICATION IS
 REQUIRED.2004 FMC 606.2.1.THIS
 COMMENT REMAINS DUE TO THE FACT ENERGY
 CALCULATIONS WERE SUBMITTED FOR 56.8 BTU
 UNIT TO BE INSTALLED.THE EQUIPMENT
 SCHEDULES SHOWN ON PLAN SHEETS M-1
 THROUGH M-8 APPEAR TO BE THE SAME.
 PLEASE CLARIFY.
  
 COMMENT 6 - OK
 COMMENT 7 - OK
  
 ***************NEW COMMENTS*************
 8.DRYER SCHEDULE PROVIDES
 MAXIMUM LENGHT OF DRYER EXHAUST WITH THE
 NUMBER OF NUMBER OF 90'S INSTALLED.
 PLEASE VERIFY LAYOUT OF EXHAUST DUCT AS
 CERTIAN RUNS APPEAR TO EXCEED THE 25 FT
 REQUIREMENT PER 2001 FMC 504.6.1.
 PLEASE NOTE, THE PLANS APPEAR TO DEPICT
 "FLEX DUCT" FOR THE EXHAUST.PER 2004
 FMC 501.4 EXHAUST DUCTS SHALL BE METAL
 AND CONSTRUCTED IN ACCORDANCE TO CHAPTER
 6.
  
 9.PLEASE PROVIDE UL LISTING
 FOR THE FLOOR/CEILING ASSEMBLY.PLEASE
 NOTE, SUBMITTAL FOR THE "PRE-ENGINEERED"
 FLOOR SYSTEM REQUIRED FOR REVIEW.
  
 10. PLEASE PROVIDE MANUFACTURE'S
 INSTALLATION INSTRUCTIONS FOR THE FIRE
 DAMPERS ON THE JOBSITE FOR INSPECTION.
  
 11. PLEASE PROVIDE OUTSIDE AIR
 CALCULATIONS IN ACCORDANCE WITH 2001 FMC
 TABLE 403.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-02-06 Cont ID  
Sent By hmoser Date 2006-02-06 Time 16:38 Rev Time 0.00
Received By hmoser Date 2006-02-06 Time 15:55 Sent To  
Notes
2006-02-06 00:00:00PLAN DENIED
 1- PLEASE REFER TO SECTION 110.1.2
 ISSUING CERTIFICATE OF OCCUPANCE #
 4,8,9,10 MUST BE ON PLANS.
 2- PLEASE SUPPLY ENERGY CALCULATIONS
 WITH PLANS SECTION 13-103.2 2004 ENERGY
 CODE.
 3- PLEASE REFER TO SECTION 607.5.2 FIRE
 BARRIERS.2004 FBC M GARAGE WALL.
 4- NEED FIRE DAMPER IN 30X10 DUCT UP TO
 2ED FLOOR.
 5- PLEASE REFER TO SECTION 606.2.1
 SUPPLY AIR SYSTEM.AND SECTION 606.4.1
 SUPERVISON.
 6- PLEASE REFRE TO SECTION 602.2.1
 METERALS EXPOSED WITHIN PLENUMS.
 7- PLEASE REFER TO SECTION 307.2.3
 AUXILIARY AND SECONDARY DRAIN SYSTEM
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-06-26 Cont ID  
Sent By pschmitz Date 2006-06-26 Time 10:21 Rev Time 0.00
Received By pschmitz Date 2006-06-26 Time 10:21 Sent To  
Notes
2006-06-26 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE,
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
 UNSAT
 1) PRREVIOUS COMMENTS #2,#3 DATED
 2-28-06 NOT ADDRESSED.
 2)THIRD FLOOR MASTER BATH WATER CLOSET
 SHOW CLEAR FLOOR SPACE AS REQUIRED IN
 THE DESIGN MANUEL, PG 7.43 CLEAR FLOOR
 SPACE AT TOILETS.
  
 3) SHT P-1 PLUMBING NOTES
 NOTE #16AIR CHAMBERS NOT APPROVED.
 REMOVE REFERENCE TO AIR CHAMBERS.
  
 SEE INCLOSED:
 COPIES OF THE FAIR HOUSING ACT.
  
  
 END OF COMMENTS QUESTIONS 561-805-66920
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-28 Cont ID  
Sent By pschmitz Date 2006-02-28 Time 09:41 Rev Time 0.00
Received By pschmitz Date 2006-02-28 Time 09:40 Sent To  
Notes
2006-02-28 00:00:00 
 PAUL SCHMITZ
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 U S DEARTMENT OF HOUSING AND URBAN
 DEVELOPMENT, FAIR HOUSING ACT.
 DENIED
 1) SHT D-3(6) BASIC FHA TYPE "B" BATH.
 DWELLINGS COVERED BY THE DESIGN
 REQUIREMENTS
 THE DESIGN REQUIREMENTS APPLY TO
 BUILDINGS BUILT
 FOR FIRST OCCUPANCY AFTER MARCH 13,
 1991, WHICH
 FALL UNDER THE DEFINITION OF ?COVERED
 MULTIFAMILY
 DWELLINGS.? SEE PAGE 12 FOR A DISCUSSION
 OF ?FIRST
 OCCUPANCY.? COVERED MULTIFAMILY
 DWELLINGS ARE:
 1. ALL DWELLING UNITS IN BUILDINGS
 CONTAINING FOUR OR
 MORE DWELLING UNITS IF SUCH BUILDINGS
 HAVE ONE
 OR MORE ELEVATORS.
  
 2)THIRD FLOOR MASTER BATH WATER CLOSET
 SHOW CLEAR FLOOR SPACE AS REQUIRED IN
 THE DESIGN MANUEL, PG 7.43 CLEAR FLOOR
 SPACE AT TOILETS.
 3) SHT P-1 PLUMBING NOTES
 NOTE #16AIR CHAMBERS NOT APPROVED.
 REMOVE REFERENCE TO AIR CHAMBERS.
  
 END OF COMMENTS QUESTIONS 561-805-6692
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-23 Cont ID  
Sent By jroach Date 2006-07-23 Time 21:51 Rev Time 0.00
Received By jroach Date 2006-07-23 Time 21:51 Sent To  
Notes
2006-07-23 00:00:007/23/2006 ***FAILED***
  
 1) SITE PLAN APPROVAL LETTER EXPIRED ON
 JUNE 25, 2006.AN EXTENSION MAY BE
 REQUESTED TO THE PLANNING AND ZONING
 DEPARTMENT.
  
 2) WALLS/FENCES WITHIN THE FRONT SETBACK
 SHALL NOT EXCEED 48 INCHES IN HEIGHT.
 AN ADDITIONAL 10% IS PERMITTED FOR
 DECORATIVE ELEMENTS ONLY.
  
 3) THE SITE DATA TABLE CALCULATES A
 DUMPSTER ALONG WITH WALKWAYS, DRIVEWAYS,
 ETC.NO DUMPSTER IS SHOWN ON THE SITE
 PLAN.IT APPEARS THAT GARBAGE WILL BE
 COLLECTED BY CURB-SIDE CANS.PLEASE
 PROVIDE A LETTER FROM THE CITY'S
 SANITATION DEPARTMENT APPROVING THE
 CURB-SIDE PICK-UP.
  
 4) PLEASE INDICATE THE LOCATION OF ALL
 A/C AND OTHER MECHANICAL EQUIPMENT.IF
 GROUND-LEVEL, LANDSCAPE PLANS SHALL ALSO
 INDICATE SUCH EQUIPMENT AND SHALL BE
 ADJUSTED TO ACCOMODATE THEIR LOCATIONS.
  
 5) WALL/FENCES/LANDSCAPING SHALL NOT BE
 PLACED WITHIN THE VISIBILITY TRIANGLES.
 NO OBSTRUCTION SHALL BE PLACED BETWEEN A
 HEIGHT OF 18 INCHES AND 8 FEET WITHIN
 SUCH TRIANGLE.
  
 6) THE LOCATIONS DESIGNATED AS THE
 "PROPERTY LINE" DO NOT CORRESPOND WITH
 THE RECORDED PLAT.PLEASE INDICATE ALL
 PROPERTY LINES IN THEIR APPROPRIATE
 LOCATIONS.
  
 7) BALCONIES, ROOF OVERHANGS, ETC. SHALL
 NOT EXTEND MORE THAN 3 FEET INTO ANY
 REQUIRED SETBACK.
  
 8) PLEASE PROVIDE A DETAIL OF THE 4 FOOT
 HIGH DECORATIVE WALL ADJACENT TO THE
 PARKING.
  
 9) THE SITE PLAN INDICATES 3 STORIES AND
 40 FEET IN HEIGHT...THE DATA TABLE AND
 ELEVATIONS INDICATE 35 FEET...PLEASE
 CLARIFY OR MAKE THEM CONSISTENT.
  
 10) AN ACCESS EASEMENT MAY BE REQUIRED
 FOR THE SIDEWALK ADJACENT TO THE
 ALLEYWAY.
  
 11) PLEASE CLARIFY OR NOTE THE DASHED
 LINES THAT EXTEND INTO THE FRONT
 SETBACK.ARE THESE THE LOCATIONS OF
 BALCONIES, ETC.?IF SO, THEY DO NOT
 APPEAR TO MATCH THE ELEVATIONS.
  
 12) A PHOTOMETRIC PLAN SHALL BE
 SUBMITTED FOR ANY/ALL EXTERIOR LIGHTING
 (I.E. PARKING LOT) AND SHALL BE
 REFLECTED AND SHIELDED AWAY FROM THE
 ADJACENT PROPERTIES AND SHALL NOT EXCEED
 0.5 FOOTCANDLES AT THE PROPERTY LINES.
  
 13) THE PARKING DETAIL ON THE SITE PLAN
 SHALL MEET THE MINIMUM DIMENSIONS OF
 SECTION 94-485 OF THE CITY'S ZONING AND
 LAND DEVELOPMENT REGULATIONS (I.E.
 DISTANCE BETWEEN STRIPING, ETC.).SEE
 ATTACHED DETAIL.
  
 14) PLEASE SHOW THE PROPERTY LINES ON
 ALL ELEVATIONS.
  
 15) THE FRONT AND SIDE ELEVATIONS DO NOT
 APPEAR TO CORRESPOND.NOT ALL ROOF
 OVERHANGS, NOR BALCONIES, ARE SHOWN ON
 THE SIDE ELEVATIONS.
  
 16) THE NOTES/DETAILS ON THE PAVEMENT
 MARKING AND SIGNAGE PLAN SHALL CONFORM
 TO THE CITY OF WPB, NOT PBC WITH
 REGARDING TO THE STRIPING OF PARKING
 SPACES, ETC.
  
 17) THE ENGINEERING SITE PLAN, AND ALL
 ASSOCIATED PLANS, DO NOT MATCH THE SITE
 PLAN (I.E. THE SIDEWALK FROM LAKE AVENUE
 ALONG THE ALLEY, ETC.).
  
 18) THE LANDSCAPE PLANS DO NOT MATCH THE
 SITE PLAN (I.E. THE SIDEWALK FROM LAKE
 AVENUE ALONG THE ALLEY, ETC.).
  
 19) THE LABELS ON THE LANDSCAPE PLAN DO
 NOT ACCURATELY POINT TO THE CORRECT
 SYMBOL.CONSIDER USING A LARGER SCALE
 AND DIFFERENT SYMBOLS FOR DIFFERENT
 SPECIES.THE CURRENT PLAN IS VERY
 DIFFICULT TO COMPREHEND.
  
 20) NO PLANTING SHALL OCCUR WITHIN THE
 VISIBILITY TRIANGLES BETWEEN A HEIGHT OF
 18 INCHES AND 8 FEET.
  
 21) THE OPEN SPACE CALCULATION (LOT AREA
 MINUS BUILDING FOOTRPINTS) SHALL BE
 PROVIDED ON THE SITE PLAN.VERIFY THAT
 THIS MATCHES WITH THE LANDSCAPE PLAN AND
 ADJUST COUNTS ACCORDINGLY.
  
 22) LANDSCAPING APPEARS TO BE IN
 CONFLICT WITH DRAINAGE, WATER AND SEWER
 LINES.ADDITIONALLY, TREES SHALL NOT BE
 LOCATED WITHIN UTILITY EASEMENTS.
 VERIFY WITH THE CITY'S PUBLIC
 UTILITIES/ENGINEERING DEPARTMENTS.
  
 23) THE LANDSCAPE DATA TABLE DOES NOT
 MATCH THE COUNTS IN THE PLANT LIST.
  
 24) ANY OLD SHEETS THAT RESULT FROM
 REVISIONS SHALL BE INDICATED WITH VOID
 AND SHALL BE REMOVED FROM THE SETS.
 ONLY 1 SET OF VOID PLANS SHALL BE
 RETAINED WITH THE SUBMITTAL FOR
 REFERENCE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 SENIOR PLANNER, AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-02-23 Cont ID  
Sent By ebowers Date 2006-02-23 Time 16:50 Rev Time 0.00
Received By ebowers Date 2006-02-23 Time 16:48 Sent To I
Notes
2006-02-23 00:00:00NEEDS TO SUBMIT A SIGNED AND SEALED
 LANDSCAPE PLAN. ADDITIONAL COMMENTS MAY
 RESULT UPON SUBMISSION. PLEASE SEE
 EDNASHA BOWERS, 822-1435