Plan Review Details - Permit 05120900
Plan Review Stops For Permit 05120900
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-03-22 Cont ID  
Sent By lmartine Date 2006-03-22 Time 15:05 Rev Time 0.00
Received By lmartine Date 2006-03-22 Time 15:05 Sent To P
Notes
2006-03-22 00:00:00 
  
 BUILDING PROVISO
 -------- -------
  
  
  
 INTERIOR DOORS SHALL COMPLY WITH FBC
 11-4.13.6 FOR MANUVERING CLEARENCES.
  
  
  
  
  
  
  
  
 L.MARTINEZ
 561-805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-03-17 Cont ID  
Sent By lmartine Date 2006-03-17 Time 17:14 Rev Time 0.00
Received By lmartine Date 2006-03-17 Time 17:14 Sent To  
Notes
2006-03-17 00:00:00 
  
  
 SEE NOTES ON PLAN FOR MANUVERING
 CLEARENCES AT INTERIOR DOORS.
  
  
  
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-03-31 Cont ID  
Sent By jleahy Date 2006-03-31 Time 14:57 Rev Time 0.00
Received By jleahy Date 2006-03-29 Time 07:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-23 Cont ID  
Sent By jleahy Date 2005-12-23 Time 07:14 Rev Time 0.45
Received By jleahy Date 2005-12-22 Time 07:05 Sent To  
Notes
2005-12-23 00:00:00NEED PANEL SCHEDULE(S)
  
 NEED LOAD CALCULATION FOR SERVICE
  
 NEED RISER DIAGRAM
  
 JAKE LEAHY644-7291

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-03-31 Cont ID  
Sent By mwennerg Date 2006-03-31 Time 13:40 Rev Time 0.00
Received By mwennerg Date 2006-03-31 Time 13:40 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-12-23 Cont ID  
Sent By mcarsill Date 2005-12-23 Time 10:13 Rev Time 0.00
Received By mcarsill Date 2005-12-23 Time 10:09 Sent To  
Notes
2005-12-23 00:00:001. DEMOLTION, RENOVATION, AND
 CONSTRUCTION TO COMPLY WITH NFPA 241.
  
 2. PLEASE ILLUSTRATE EXIT SIGN AND
 EMERGENCY LIGHTING LOCATIONS.
  
 3. PLEASE DISPLAY ALL FIRE EXTINGUISHER
 LOCATIONS.
  
 4. RATED FIRE DOORS SHOWN ON THE PLANS
 MUST BE EQUIPPED WITH SELF-CLOSING
 DEVICES AND POSITIVELY LATCH WHEN
 CLOSED.
  
 5. PLEASE ENSURE THAT THE ADDRESS IS
 PRESENT ON THE BUILDING.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-21 Cont ID  
Sent By dpalmer Date 2006-03-21 Time 18:48 Rev Time 0.00
Received By lmartine Date 2006-03-21 Time 18:48 Sent To  
Notes
2006-03-22 00:00:00OK TO EXPIDITE PER LUIS
2006-03-21 00:00:00WAITING FOR COMM BOARD NOT BOB, EXTERIOR
 COMPONENTS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-17 Cont ID  
Sent By lmartine Date 2006-03-17 Time 17:16 Rev Time 0.00
Received By lmartine Date 2005-12-19 Time 16:30 Sent To  
Notes
2006-03-17 00:00:00PLANS WERE FILED MISTAKENLY FOR ALMOST 3
 MONTH
2005-12-19 00:00:00TO "BOB"#3

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-12-20 Cont ID  
Sent By tgordon Date 2005-12-20 Time 13:38 Rev Time 0.15
Received By tgordon Date 2005-12-20 Time 13:38 Sent To  
Notes
2005-12-20 00:00:00NO MECH. PLANS OR MECH. CONTRACTOR
 SUBMITTED AT THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-03-23 Cont ID  
Sent By jleech Date 2006-03-23 Time 08:01 Rev Time 0.00
Received By jleech Date 2006-03-23 Time 08:01 Sent To E
Notes
2006-03-31 00:00:00PROVISO;
  
 1.BATHROOM AND BREAKROOM DOORS MUST
 SWING OUT. NOT PERMITED IN CLEAR FLOOR
 SPACE OF THE HANDICAP FIXTURES.
 2.TOILET ROUGH IS 18" OFF WALL DOOR
 SIDE. GRAB BARS REQUIRED.
 3.REVISED DRAWINGS REQUIRED SHOWING
 ABOVE REQUESTED CHANGES.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
2006-03-23 00:00:00 
  
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By jleech Date 2005-12-20 Time 09:18 Rev Time 1.50
Received By jleech Date 2005-12-20 Time 09:18 Sent To  
Notes
2005-12-20 00:00:00DENIED;
 1. SHOW COMPLIANCE TO FBC-2004 PLUMBING
 TABLE 403.1. SHOW TYPE OCCUPANCY, SQUARE
 FOOTAGE AND NUMBER OF EMPLOYEES.
 2.DRINKING FOUNTAIN REQUIRED TABLE
 403.1.
 3.SINK SHALL COMPLY WITH FBC-2004
 CHAPTER 11, SEC. 11-4.24.1 THRU
 11-4.24.7. (SHOW DETAIL)
 4.HANDICAP BATHROOM; DOOR SWING SHALL
 NOT SWING INTO CLEAR FLOOR SPACE OF
 PLUMBING FIXTURE. TOILET SHALL BE
 LOCATED IN THE CORNER DIAGONAL TO THE
 DOOR. (FIG. 30E NOTES).
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695