| Plan Review Stops For Permit 05120836 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-10 |
Time |
15:06 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-02-09 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-20 |
Time |
10:38 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-01-20 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | DENIED | | | | | | SUBMIT SLAB DETAIL AND METHOD OF | | | TIE-DOWN FOR GENERATOR. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-09 |
Time |
08:29 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-02-09 |
Time |
07:56 |
Sent To |
PC |
|
| Notes |
| 2006-02-10 00:00:00 | 700.6 TRANSFER EQUIPMENT. | | | (A) GENERAL. TRANSFER EQUIPMENT, | | | INCLUDING AUTOMATIC TRANSFER SWITCHES, | | | SHALL BE AUTOMATIC, IDENTIFIED FOR | | | EMERGENCY USE, AND APPROVED BY THE | | | AUTHORITY HAVING JURISDICTION. TRANSFER | | | EQUIPMENT SHALL BE DESIGNED AND | | | INSTALLED TO PREVENT THE INADVERTENT | | | INTERCONNECTION OF NORMAL AND EMERGENCY | | | SOURCES OF SUPPLY IN ANY OPERATION OF | | | THE TRANSFER EQUIPMENT. TRANSFER | | | EQUIPMENT AND ELECTRIC POWER PRODUCTION | | | SYSTEMS INSTALLED TO PERMIT OPERATION IN | | | PARALLEL WITH THE NORMAL SOURCE SHALL | | | MEET THE REQUIREMENTS OF ARTICLE 705. | | 2006-02-09 00:00:00 | | | | THE RISER DIAGRAM' S SUBMITTED ARE | | | INCOMPLETE. THEY DO NOT SHOW HOW THE ATS | | | FEEDS THE DISCONNECTS. | | | PLEASE SUBMIT A COMPLETE RISER SHOWING | | | ALL EQUIPMENT, GROUNDING, CONDIUT AND | | | CONDUCTOR SIZES. THE RISER'S (TWO | | | DIFFERENT ONE'S) SHOW THE ATS BEING FED | | | FROM THE GENERATOR WITH A CONDUIT TO THE | | | METER? | | | | | | PLEASE RESUBMIT A CXOMPLETED RISER | | | DIAGRAM (2 COPIES). | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-10 |
Time |
18:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-01-10 |
Time |
18:12 |
Sent To |
M |
|
| Notes |
| 2006-01-10 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE TOTAL COST OF THE JOB MUST BE | | | INCLUDED IN THE VALUATION ON THE | | | APPLICATION. THIS INCLUDES THE GENERATOR | | | AND ALL EQUIPMENT BEING INSTALLED AND | | | LABOR. | | | | | | 2} PLEASE REDRAW THE RISER DIAGRAM TO | | | INCLUDE NEW PANELS FOR LOAD SHEDDING. | | | ALSO IT ISN'T CLEAR FROM THE DRAWING | | | SUBMITTED HOW THE ATS TIES IN. | | | | | | 3} PROVIDE A SITE PLAN INDICATING THE | | | LOCATION OF ALL SERVICE AND GENERATOR | | | EQUIPMENT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-11 |
Time |
12:50 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-11 |
Time |
12:50 |
Sent To |
B |
|
| Notes |
| 2006-01-11 00:00:00 | GAS PERMIT REQUIRED. GAS CONTRACTOR TO | | | SUBMIT PLANS WITH PERMIT APPLICATION. | | | FINAL GAS INSPECTION REQUIRED BEFORE | | | FINAL RES-GEN INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-09 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-09 |
Time |
08:52 |
Sent To |
E |
|
| Notes |
| 2006-01-09 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-20 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-12-16 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2005-12-16 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-11 |
Time |
08:47 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-01-11 |
Time |
08:47 |
Sent To |
G |
|
| Notes |
| 2006-01-11 00:00:00 | *** PROVISO *** | | | 1) GENERATOR EXHUST MUST BE TEN FEET | | | AWAY FROM ANY BUILDING OPENINGS | | | (WINDOWS, DOORS, ROOF & EAVE VENTS), AND | | | TEN FEET AWAY FROM ADJECENT BUILDING | | | OPENS. PER 2004 FBC/M 401.5.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-11 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-01-11 |
Time |
12:49 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-01-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-07 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-07 |
Time |
07:55 |
Sent To |
I |
|
| Notes |
|
|