Plan Review Details - Permit 05120777
Plan Review Stops For Permit 05120777
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-06 Cont ID  
Sent By amorse Date 2006-07-06 Time 08:15 Rev Time 1.00
Received By amorse Date 2006-07-06 Time 08:15 Sent To E
Notes
2006-07-06 00:00:00 
  
 DENIED
  
 1) BEFORE THE FOLLOWING CORRECTIONS ARE
 MADE PLEASE VERIFY THAT GARAGE CAN BE
 BUILT IN THE SETBACKS SHOWN IF NOT MAJOR
 CHANGES MAY BE REQUIRED
  
 2) PROVIDE DETAIL ON NEW 2'-0" WALL THAT
 RUNS PERIMETER OF PATIO SLAB. SHALL
 CONTAIN BOND BEAM, VERTICAL COLUMNS, TIE
 INS AT 1'-4" COLUMNS
  
 3) PROVIDE DETAIL OF HEADER OR FRAMING
 AT GARAGE DOOR OPENING AS THIS IS NEW ON
 DRAWING. (SEE SECTION B ON S1.1) DETAIL
 16 ON S1.3 ONLY SHOWS TOP BEAM, HOW IS
 THE DOOR HEADER OR FRAMING ATTACHED
  
 4) MINIMUM ROOF SHEATHING FOR 24"
 CENTERS IS 5/8" PER R803.1 FBC
  
 5) ROOF OVERHANG DETAIL DOES NOT SEEM
 ADEQUATE? SUGGEST THAT WALL IS DROPPED
 3 1/2" AND OUTLOOKERS SET ON TOP OF WOOD
 PLATE AND ARE ATTACHED WITH HURRICANE
 CLIPS, THEY WOULD ALSO RUN IN TO THE
 FIRST RAFTER AND BE ATTACHED. ALSO
 PROVIDE PROJECTION SIZE
  
 6) DOORS ARE GENERALLY ATTACHED TO
 PRESURE TREATED WOOD BUCKS. THEY SHALL
 BE DESIGNED WITH ATTACHMENT THAT
 TRANSFERS THE LOADS TO THE STRUCTURE.
 PROVIDE DETAIL/NOTE FOR BUCK ATTACHMENT
 (SEE PAGE 3 OF DOOR PRODUCT APPROVAL)
 NOTE GARAGE DOOR ATTACHMENT IS INCLUDED
 IN THE PRODUCT APPROVAL
  
 7) SINGLES SHALL NOT BE USED ON SLOPES
 LESS THAN 2/12 PER 1507.2.2 FBC
  
 8) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-24 Cont ID  
Sent By amorse Date 2006-01-24 Time 09:12 Rev Time 2.00
Received By amorse Date 2006-01-24 Time 09:12 Sent To PC
Notes
2006-01-24 00:00:00 
  
 DENIED
  
  
 1) DRAWINGS SHALL COMPLY WITH FBC 2004
 AND THECITY OF WPB AMMENDMENTS
  
 2) ADJUST VALUATION IT IS TO LOW FOR
 THIS WORK. VALUE SHOULD INCLUDE ALL
 LABOUR AND MATERIALS TO COMPLETE WORK.
 WE USE MARHALL AND SWIFT CONSTRUCTION
 VALUATION MANUAL THAT PUTS A VALUE CLOSE
 TO $18,000.00 FOR THIS WORK
  
 3) ALL DRAWINGS AND SPECIFICATIONS SHALL
 BE SIGNED AND DATED BY THE PERSON
 RESPONSIBLE FOR THEM
  
 4) SUBMIT 2 COPIES OF THE SITE PLAN WITH
 THE LOCATION OF THE PATIO AND GARAGE
 SHOWN, ALSO MARK IN ALL SETBACK
 MEASUREMENTS
  
 5) SPECIFY IF GARAGE IS TO BE OPEN
 (CARPORT) OR WILL IT HAVE DOORS
 INSTALLED. IF DOORS ARE TO BE INSTALLED
 SUBMIT A BUCK ATTACHMENT DETAIL FOR BOTH
 OPENINGS
  
 6) SPECIFY TYPE OF LUMBER AND GRADE TO
 BE USED FOR ROOF FRAMING MEMBERS ON
 GARAGE AND PATIO
  
 7) SPECIFY SIZE OF REINFORCING STEEL IN
 BOND BEAM
  
 8) VERIFY THAT EPOXY BOLT DETAIL 13 ON
 S1.2 IS INTO EXISTING TIE BEAM
  
 9) SHOW ELEVATION DETAIL OF GARAGE
 OPENING TO CLARIFY BEAM ATTACHMENT AT
 BOTH EXISTING HOUSE AND NEW WALL
  
 10) SPECIFY WALL FINISHES TO BE APPLIED
 TO CMU BLOCK WALLS EG. STUCCO, SIDING
  
 11) ENGINEERING SHALL BE PROVIDED THAT
 VARIFIES THE LATERAL PRESSURES ON THE
 BEAM TO WALL CONNECTION ARE ACCEPTABLE
 AND THAT THE BEAM SPAN WILL WORK FOR
 GARAGE OPENING. ALSO THAT THE BEAM SPANS
 THAT CARRY THE PATIO ROOF JOISTS WILL
 WORK.
  
 12) TERMITE PROTECTION SHALL BE PROVIDED
 PER SECTION 1816 FBC 2004 OR R320.1 FBC
 RES. PRIOR TO CONCRETE SLAB PLACEMENT
  
 13) SUBMIT PRODUCT APPROVALS FOR ROOF
 COVERING AND IF NEEDED SWINGING DOOR AND
 GARAGE SECTIONAL DOOR
  
 14) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL PAGE
 THAT IS RELEVANT. THESE SHOULD INCLUDE
 THE FLORIDA STATE APPROVAL COVER PAGES,
 AND THE PRODUCT NOA THAT LISTS THE
 SYSTEM COMPONENTS/ FASTENER LIST PAGES,
 THE PAGES WITH THE CHOSEN ASSEMBLY/
 SYSTEM TO BE USED AND THE GENERAL
 LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 15) A RADON SURCHARGE FEE SHALL BE PAID
 FOR ALL UNDER ROOF FLOOR SPACE WHICH
 INCLUDES ATTACHED CARPORTS, GARAGES,
 PORCHES, UTILITY ROOMS AND STORAGE ROOMS
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-07 Cont ID  
Sent By dpalmer Date 2006-07-07 Time 12:01 Rev Time 0.00
Received By dpalmer Date 2006-07-07 Time 11:46 Sent To PC
Notes
2006-07-07 00:00:00*********** UNSAT ************
  
 1) NOTE: PLEASE INDICATE THE SWITCHING
 CONTROLS FOR ALL NEW LIGHTING FIXTURES.
 210.70, LS101
  
 2) NOTE: PLEASE SEE MISSING GFI RECEPT
 REQUIRED FOR GARAGE. 210.8A, 250.52G
  
 3) NOTE: PLEASE SEE RECEPT SHOWN FOR GDO
 CAN NOT BE A DUPLEX RECEPT AS SHOWN.
 THIS MUST BE A DEDICATED SINGLE RECEPT
 RATED FOR THE NEW GDO.
 430, 430.148
  
 4) NOTE: PLEASE PROVIDE INFORMATION ON
 THE NEW CIRCUIT(S) BEING PROVIDED FOR
 THE GDO AND IF THE LIGTHING AND GARAGE
 RECEPTS WILL BE FROM EXISTING OR NEW
 CIRCUITS.
 106.1.2 FBC ADMIN SECT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 11:11 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 11:11 Sent To B
Notes
2006-07-05 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-30 Cont ID  
Sent By adarroug Date 2006-06-30 Time 10:06 Rev Time 0.00
Received By adarroug Date 2006-06-30 Time 10:06 Sent To Z
Notes
2006-06-30 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-05 Cont ID  
Sent By adarroug Date 2006-01-05 Time 09:25 Rev Time 0.00
Received By adarroug Date 2006-01-05 Time 09:25 Sent To B
Notes
2006-01-05 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-03 Cont ID  
Sent By amorse Date 2006-01-24 Time 11:32 Rev Time 0.00
Received By amorse Date 2005-12-16 Time 10:35 Sent To  
Notes
2005-12-16 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-07-07 Cont ID  
Sent By dpalmer Date 2006-07-07 Time 12:04 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
2006-07-07 00:00:00NO WORK BEING DONE IN THIS TRADE

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-07-07 Cont ID  
Sent By dpalmer Date 2006-07-07 Time 12:04 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
2006-07-07 00:00:00NO WORK BEING DONE IN THIS TRADE

Review Stop Z ZONING
Rev No 2 Status F Date 2006-07-02 Cont ID  
Sent By mmclean Date 2006-07-02 Time 18:08 Rev Time 0.00
Received By mmclean Date 2006-07-02 Time 18:08 Sent To I
Notes
2006-07-02 00:00:00DENIED.
 1. MUST SHOW CLEARING THE LOCATION OF
 THE PROPOSED GARAGE IN THE REAR CLEARLY.
 2. THE SURVEY SHOWS THE STRUCTURE AT
 6'6" AS REAR SETBACK AND 10FT AS A REAR
 SETBACK.PLEASE SHOW AND INDICATE
 CLEARLY THE SETBACK FOR THE PROPOSED
 GARAGE.
 3. REAR SETBACK OF PROPOSED GARAGE MUST
 BE 10% OR 15FT OF LOT DEPTH, WHICHEVER
 IS LESS.
 4. NEED TO SHOW ON THE TWO COPY OF
 SURVEY THE ACCESS TO GETTING INTO THE
 PROPOSED GARAGE BY THE SIDE PROPERTY.
 NEED TO SHOW THE WIDTH & LENGTH OF
 PROPOSED DRIVEWAY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-04 Cont ID  
Sent By mmclean Date 2006-01-04 Time 16:44 Rev Time 0.00
Received By mmclean Date 2006-01-04 Time 07:10 Sent To I
Notes
2006-01-04 00:00:00DENIED, MUST SHOW LOCATION OF NEW PORCH
 & GARAGE ON THE SITE PLAN WITH THE
 SETBACKS INFORMATION