Plan Review Details - Permit 05120752
Plan Review Stops For Permit 05120752
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-02-13 Cont ID  
Sent By mjacobs Date 2006-02-13 Time 18:16 Rev Time 0.50
Received By mjacobs Date 2006-02-13 Time 17:59 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-02-04 Cont ID  
Sent By mjacobs Date 2006-02-04 Time 14:04 Rev Time 1.00
Received By mjacobs Date 2006-02-04 Time 13:07 Sent To PC
Notes
2006-02-04 00:00:00 
 1) A NOTORIZE LETTER FROM THE OWNER IS
 REQUIRED, STATING THAT HE/SHE WILL
 REMOVE THE AWNINGE IN PERIODS OF HIGH
 WINDS OF 75 MPH.3105.5.1 LOADS.
 RIGID AWNINGS AND CANOPY SHUTTERS SHALL
 BE DESIGNED TO RESIST THE LOADS SET
 FORTH IN CHAPTER 16 OF THIS CODE EXCEPT
 THAT STRUCTURES OR PARTS THEREOF WHICH
 ARE INTENDED TO BE REMOVED OR
 REPOSITIONED DURING PERIODS OF HIGH WIND
 VELOCITY SHALL BE DESIGNED IN THEIR OPEN
 OR EXTENDED POSITION TO DESIGN PRESSURES
 BASED ON A BASIC WIND SPEED OF MINIMUM
 90 MPH, 3-SECOND WIND GUST WITH
 APPLICABLE SHAPE FACTORS AND TO RESIST
 NOT LESS THAN 10 PSF (478 PA) ROOF LIVE
 LOAD.
  
 2) 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH
 A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR
 FABRIC AT WIND VELOCITIES OF 75 MPH,
 SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1.MINIMUM WIND VELOCITY OF 3-SECOND
 WIND GUST 90 MPH
 2.IMPORTANCE FACTOR BASED ON LOW
 HAZARD TO HUMAN LIFE OF 0.77.
 3.EXPOSURE CATEGORY B FOR OR C AS
 DEFINED IN CHAPTER 16 .
  
 3) 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-10 Cont ID  
Sent By adarroug Date 2006-02-10 Time 12:13 Rev Time 0.00
Received By adarroug Date 2006-02-10 Time 12:13 Sent To B
Notes
2006-02-10 00:00:00TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-17 Cont ID  
Sent By adarroug Date 2006-01-17 Time 08:46 Rev Time 0.00
Received By adarroug Date 2006-01-17 Time 08:46 Sent To B
Notes
2006-01-17 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-02-04 Time   Rev Time 0.00
Received By adarroug Date 2005-12-15 Time 10:11 Sent To  
Notes
2005-12-15 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2006-01-13 Cont ID  
Sent By astelly Date 2006-01-13 Time 10:08 Rev Time 0.00
Received By astelly Date 2006-01-13 Time 10:08 Sent To  
Notes
2006-01-13 00:00:00GIVEN TO INCOMING.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved