2006-01-11 00:00:00BUILDING REVIEW CHECKLIST:
 1- THERE ARE 2 DIFFERENT REPORTS
 SUBMITTED. ONE IS A DADE COUNTY NOA AND
 THE OTHER ONE IS A TESTING REPORT (WHICH
 EXPIRED ON 2-05-05). NONE OF THE REPORTS
 SUBMITTED MATCH INFORMATION SUBMITTED
 FOR FLORIDA PRODUCT APPROVAL.
  
 2- DADE COUNTY NOA ALONE IS NOT
 AUTOMATICALLY AN STATEWIDE FLORIDA
 PRODUCT APPROVAL. MANUFACTURER MAY APPLY
 FOR LOCAL PRODUCT APPROVAL USING THE
 DADE COUNTY NOA AND COMPLETING THE LOCAL
 PRODUCT APPROVAL FORM.
  
 3- ALWAYS PROVIDE TWO COPIES OF PRODUCT
 APPROVALS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-01-03 Cont ID  
Sent By jgomez Date 2006-01-03 Time 14:07 Rev Time 0.50
Received By jgomez Date 2006-01-03 Time 14:07 Sent To  
Notes
2006-01-03 00:00:00BUILDING REVIEW CHECKLIST:
 1- FLORIDA PRODUCT APPROVAL FL 5985 IS
 NOT APPROVED YET. IT IS UNDER THE
 APPROVAL PROCESS. PRODUCT APPROVAL MUST
 HAVE AN APPROVED STATUTES IN ORDER TO BE
 USED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-12-22 Cont ID  
Sent By jgomez Date 2005-12-22 Time 08:46 Rev Time 0.33
Received By jgomez Date 2005-12-22 Time 08:46 Sent To  
Notes
2005-12-22 00:00:00BUILDING REVIEW CHECKLIST:
 1- DESIGN PRESSURES FOR THIS SYSTEM ARE
 52.5PSF. DESIGN PRESSURES AT PERIMETER
 AND CORNERS ARE HIGHER. SEE TABLE
 1609.6B FBC 2004. ACCORDING TO THE
 LIMITS OF USE OF THIS PRODUCT APPROVAL
 NEED RATIONAL ANALYSIS COMPUTATIONS AND
 SHALL BE PREPARED BY A QUALIFIED DESIGN
 PROFESSIONAL. PROVIDE 2 COPIES OF
 CALCULATIONS WITH PROFESSIONAL ORIGINAL
 SEAL, SIGNATURE AND DATE AS REQUIRED BY
 CHAPTER 471 AND 481 FLORIDA STATUTES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-13 Cont ID  
Sent By jgomez Date 2005-12-13 Time 16:15 Rev Time 0.50
Received By jgomez Date 2005-12-13 Time 15:15 Sent To PC
Notes
2005-12-13 00:00:00BUILDING REVIEW CHECKLIST:
 1- PERMIT APPLICATIONS SUBMITTED AFTER
 OCTOBER 1ST 2005 NEED TO COMPLY WITH FBC
 2004.PRODUCT APPROVALS NEED TO BE
 UPDATED TO THE 2004 CODE VERSION.
 PRODUCT APPROVAL FOR METAL ROOFING
 SUBMITTED IS FOR 2001 CODE. GO TO
 WEBSITE WWW.FLORIDABUILDING.ORG TO
 VERIFY IF METAL ROOFING MANUFACTURER
 HAVE APPLIED FOR THE 2004 CODE EDITION.
  
 2- ACCORDING TO THE LIMITS OF USE OF THE
 FLORIDA PRODUCT APPROVAL NEED RATIONAL
 ANALYSIS COMPUTATIONS PREPARED BY A
 QUALIFIED DESIGN PROFESSIONAL. PROVIDE
 ALL INFORMATION AS REQUIRED.
  
 3- DADE COUNTY NOA SUBMITTED IS NOT PART
 OF THE INFORMATION THAT WAS SUBMITTED
 FOR FLORIDA PRODUCT APPROVAL. PROVIDE
 ONLY THE INFORMATION THAT WAS REVIEWED
 AND APPROVED BY THE FLORIDA BUILDING
 COMMISSION.
  
 4- OWES $56.36 VALUE DECLARED ON THE
 PERMIT APPLICATION WAS UPDATED. SEC.
 108.3 CITY AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712