Plan Review Details - Permit 05120673
| Plan Review Stops For Permit 05120673 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-08 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-08 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2006-03-08 00:00:00 | PROVISO - SEPARATE PERMIT FOR SHUTTERS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-31 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-01-31 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2006-01-31 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)SEE PREVIOUS LIST IN REGARDS TO | | | IMPACT PROTECTION.IF THIS QUALIFIES | | | FOR THE EXCEPTION FBC EB507.3, PLEASE | | | PROVIDE CALCULATIONS SHOWING THAT THESE | | | THREE OPENINGS ARE LESS THAN 25% OF THE | | | TOTAL GLAZED AREA. | | | | | | 2.)THE ADDRESS ON YOUR APPLICATION | | | CONFLICTS WITH THE ADDRESS FOR THE | | | PARCEL ID YOU HAVE PROVIDED. | | | | | | 3.)THE NOC REFERS TO A PARCEL ID | | | NUMBER BUT IT IS INCOMPLETE.ITEM | | | NUMBER 1 SHOULD INCLUDE THE ADDRESS AS | | | WELL AS THE LEGAL DESCRIPTION.PLEASE | | | CLARIFY WHICH PARCEL YOU ARE WORKING ON, | | | 846 SELKIRK OR 847 SELKIRK.PLEASE GO | | | TO PBCGOV.COM/PAPA FOR MORE INFORMATION. | | | | | | 4.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED.IT WAS PROVIDED FOR | | | THE DUAL ACTION WINDOW BUT NOT FOR THE | | | IMPACT WINDOW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-14 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-01-14 |
Time |
18:40 |
Sent To |
|
|
| Notes |
| 2006-01-14 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 2.)THE NON IMPACT WINDOW PRODUCT | | | APPROVAL SUBMITTED IS NOT A DUAL ACTION | | | WINDOW.THE BEDROOM WINDOWS DO NOT MEET | | | EMERGENCY EGRESS REQUIREMENTS FBC R310. | | | ADDRESS. | | | | | | 3.)IF NON IMPACT WINDOWS ARE | | | INSTALLED, IMPACT PROTECTION REQUIRED | | | FBC EB507.3. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-02 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-02 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
| 2006-03-02 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-28 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-28 |
Time |
16:23 |
Sent To |
B |
|
| Notes |
| 2006-01-28 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-14 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-12-15 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2005-12-15 00:00:00 | TO "MISC" BOX#1 |
|
|
|